Mechanical testing of hydrogels in cartilage tissue engineering: beyond the compressive modulus.

Injuries to articular cartilage result in significant pain to patients and high medical costs. Unfortunately, cartilage repair strategies have been notoriously unreliable and/or complex. Biomaterial-based tissue-engineering strategies offer great promise, including the use of hydrogels to regenerate articular cartilage. Mechanical integrity is arguably the most important functional outcome of engineered cartilage, although mechanical testing of hydrogel-based constructs to date has focused primarily on deformation rather than failure properties. In addition to deformation testing, as the field of cartilage tissue engineering matures, this community will benefit from the addition of mechanical failure testing to outcome analyses, given the crucial clinical importance of the success of engineered constructs. However, there is a tremendous disparity in the methods used to evaluate mechanical failure of hydrogels and articular cartilage. In an effort to bridge the gap in mechanical testing methods of articular cartilage and hydrogels in cartilage regeneration, this review classifies the different toughness measurements for each. The urgency for identifying the common ground between these two disparate fields is high, as mechanical failure is ready to stand alongside stiffness as a functional design requirement. In comparing toughness measurement methods between hydrogels and cartilage, we recommend that the best option for evaluating mechanical failure of hydrogel-based constructs for cartilage tissue engineering may be tensile testing based on the single edge notch test, in part because specimen preparation is more straightforward and a related American Society for Testing and Materials (ASTM) standard can be adopted in a fracture mechanics context.

[1]  Clarke Ic Surface characteristics of human articular cartilage--a scanning electron microscope study. , 1971 .

[2]  Yoshimi Tanaka,et al.  True Chemical Structure of Double Network Hydrogels , 2009 .

[3]  Yoshihito Osada,et al.  Biodegradation of high-toughness double network hydrogels as potential materials for artificial cartilage. , 2007, Journal of biomedical materials research. Part A.

[4]  A. P. Jackson Measurement of the fracture toughness of some contact lens hydrogels. , 1990, Biomaterials.

[5]  H J Helminen,et al.  Comparison of the equilibrium response of articular cartilage in unconfined compression, confined compression and indentation. , 2002, Journal of biomechanics.

[6]  Michael S Detamore,et al.  Hierarchically designed agarose and poly(ethylene glycol) interpenetrating network hydrogels for cartilage tissue engineering. , 2010, Tissue engineering. Part C, Methods.

[7]  Sandra L. Johnson,et al.  Collagen architecture and failure processes in bovine patellar cartilage , 2001, Journal of anatomy.

[8]  J. Mainstone,et al.  Analysis of tear film breakup on Etafilcon A hydrogel lenses. , 2001, Biomaterials.

[9]  A. Khademhosseini,et al.  BIOMIMETIC GRADIENT HYDROGELS FOR TISSUE ENGINEERING. , 2010, The Canadian journal of chemical engineering.

[10]  The determination of fracture mechanics properties of pharmaceutical materials in mode III loading using an anti-clastic plate bending method. , 2001, International journal of pharmaceutics.

[11]  M. Farshad,et al.  Investigation of mode III fracture toughness using an anti-clastic plate bending method , 1998 .

[12]  D. Seliktar,et al.  Polymer-conjugated albumin and fibrinogen composite hydrogels as cell scaffolds designed for affinity-based drug delivery. , 2011, Acta biomaterialia.

[13]  Benedicte Vanwanseele,et al.  A review on the mechanical quality of articular cartilage - implications for the diagnosis of osteoarthritis. , 2006, Clinical biomechanics.

[14]  M. L. Hall,et al.  Effect of indenter size on elastic modulus of cartilage measured by indentation. , 2007, Journal of biomechanical engineering.

[15]  Jian Ping Gong,et al.  Double-Network Strategy Improves Fracture Properties of Chondroitin Sulfate Networks. , 2013, ACS macro letters.

[16]  Youyong Li,et al.  First-Principles Based Approaches to Nano-Mechanical and Biomimetic Characterization of Polymer-Based Hydrogel Networks for Cartilage Scaffold-Supported Therapies , 2010 .

[17]  T. Kurokawa,et al.  Double‐Network Hydrogels with Extremely High Mechanical Strength , 2003 .

[18]  R. Sah,et al.  Biomechanics of integrative cartilage repair. , 1999, Osteoarthritis and cartilage.

[19]  A. Oloyede,et al.  Conceptual fracture parameters for articular cartilage. , 2007, Clinical biomechanics.

[20]  Henning Madry,et al.  The basic science of the subchondral bone , 2010, Knee Surgery, Sports Traumatology, Arthroscopy.

[21]  T. Kurokawa,et al.  Determination of fracture energy of high strength double network hydrogels. , 2005, The journal of physical chemistry. B.

[22]  Jian Ping Gong,et al.  Why are double network hydrogels so tough , 2010 .

[23]  Burak Erman,et al.  Structures and properties of rubberlike networks , 1997 .

[24]  O. Okay,et al.  Design of high-toughness polyacrylamide hydrogels by hydrophobic modification , 2009 .

[25]  J. Lewis,et al.  Fracture of articular cartilage. , 1996, Journal of biomechanical engineering.

[26]  Junmin Zhu,et al.  Bioactive modification of poly(ethylene glycol) hydrogels for tissue engineering. , 2010, Biomaterials.

[27]  R. Zhuo,et al.  Photoresponsive ``Smart Template'' via Host-Guest Interaction for Reversible Cell Adhesion , 2011 .

[28]  T. J. Young,et al.  AFM indentation method used for elastic modulus characterization of interfaces and thin layers , 2010 .

[29]  G. Ateshian,et al.  Mechanical properties of bovine articular cartilage under microscale indentation loading from atomic force microscopy , 2009, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[30]  Glenister Tw An embryological view of cartilage. , 1976 .

[31]  J. Lewis,et al.  Effect of specimen thickness on fracture toughness of bovine patellar cartilage. , 2003, Journal of biomechanical engineering.

[32]  J. Gong,et al.  Soft and Wet Materials: From Hydrogels to Biotissues , 2010 .

[33]  K. Gall,et al.  On the toughness of photopolymerizable (meth)acrylate networks for biomedical applications , 2009 .

[34]  Santanu Kundu,et al.  Cavitation and fracture behavior of polyacrylamide hydrogels , 2009 .

[35]  D. Mooney,et al.  Independent Control of Rigidity and Toughness of Polymeric Hydrogels , 2003 .

[36]  E B Hunziker,et al.  Importance of the superficial tissue layer for the indentation stiffness of articular cartilage. , 2002, Medical engineering & physics.

[37]  Chaenyung Cha,et al.  Biodegradable Polymer Crosslinker: Independent Control of Stiffness, Toughness, and Hydrogel Degradation Rate , 2009 .

[38]  J. Lewis,et al.  Evaluation of fracture toughness of cartilage by micropenetration , 2004, Journal of materials science. Materials in medicine.

[39]  T. Glenister An embryological view of cartilage. , 1976, Journal of anatomy.

[40]  R. Coutts,et al.  Indentation testing of human cartilage: sensitivity to articular surface degeneration. , 2003, Arthritis and rheumatism.

[41]  Xiongbiao Chen,et al.  Mechanical properties of natural cartilage and tissue-engineered constructs. , 2011, Tissue engineering. Part B, Reviews.

[42]  E. Morgan,et al.  Use of microindentation to characterize the mechanical properties of articular cartilage: comparison of biphasic material properties across length scales. , 2010, Osteoarthritis and cartilage.

[43]  A H Huang,et al.  Tensile properties of engineered cartilage formed from chondrocyte- and MSC-laden hydrogels. , 2008, Osteoarthritis and cartilage.

[44]  T. Kurokawa,et al.  Direct Observation on the Surface Fracture of Ultrathin Film Double-Network Hydrogels , 2011 .

[45]  Walter Herzog,et al.  Uncertainties in indentation testing of articular cartilage: a fibril-reinforced poroviscoelastic study. , 2008, Medical engineering & physics.

[46]  A. U. Daniels,et al.  Micro- and nanomechanical analysis of articular cartilage by indentation-type atomic force microscopy: validation with a gel-microfiber composite. , 2010, Biophysical journal.

[47]  B. Lawn,et al.  Indentation fracture: principles and applications , 1975 .

[48]  Yoshimi Tanaka,et al.  SUPER TOUGH GELS WITH A DOUBLE NETWORK STRUCTURE , 2009 .

[49]  A Oloyede,et al.  A qualitative analysis of crack propagation in articular cartilage at varying rates of tensile loading. , 2003, Connective tissue research.

[50]  C. Radke,et al.  Fenestrations enhance tear mixing under silicone-hydrogel contact lenses. , 2003, Investigative ophthalmology & visual science.

[51]  L Keay,et al.  Tear exchange under hydrogel contact lenses: methodological considerations. , 2001, Investigative ophthalmology & visual science.