Accuracy improvement in gait analysis measurements: Kinematic modeling

Postural and motor changes in patients affected by abnormalities of movement are the results of the interactions of nervous system, musculoskeletal system and sensorial system. Gait analysis is a good technique to characterize various gait pathologies, and a high accuracy of the results is necessary in order to describe, in quantitative way, functional limitation related to the pathology. In this paper the model for modeling the kinematics of human body is implemented by considering data acquired from a camera of optoelectronic system capable of measuring three-dimensional coordinates of reflective markers placed in known positions on the patient. Kinematic model is reported for pelvis and accuracy of its trajectories acquired by cameras is also investigated. Moreover, since coordinate system of the other joints (hip, ankle, foot) are relative respect pelvic coordinate system, accuracy in its model can reduce errors in evaluation of essential angles to define human motion.

[1]  R. B. Davis,et al.  A gait analysis data collection and reduction technique , 1991 .

[2]  Vikrant Bhateja,et al.  Entropy Index in Quantitative EEG Measurement for Diagnosis Accuracy , 2014, IEEE Transactions on Instrumentation and Measurement.

[3]  Amerigo Trotta,et al.  Processing stabilometric data for electronic knee: Training and calibration , 2010, 2010 IEEE Instrumentation & Measurement Technology Conference Proceedings.

[4]  M. Ferrarin,et al.  A multiple-task gait analysis approach: kinematic, kinetic and EMG reference data for healthy young and adult subjects. , 2011, Gait & posture.

[5]  J. Perry,et al.  Comprar Gait analysis. Normal and pathological function | Burnfield, J. | 9781556427664 | Slack Incorporated , 2010 .

[6]  Alfred D. Grant Gait Analysis: Normal and Pathological Function , 2010 .

[7]  Vikrant Bhateja,et al.  Spatial filtering to detect brain sources from EEG measurements , 2014, 2014 IEEE International Symposium on Medical Measurements and Applications (MeMeA).

[8]  J. Gage,et al.  An update on the treatment of gait problems in cerebral palsy. , 2001, Journal of pediatric orthopedics. Part B.

[9]  Kevin J Deluzio,et al.  A biomechanical analysis of trunk and pelvis motion during gait in subjects with knee osteoarthritis compared to control subjects. , 2010, Clinical biomechanics.

[10]  C. Charalambous Repeatability of Kinematic, Kinetic, and Electromyographic Data in Normal Adult Gait , 2014 .

[11]  M P Kadaba,et al.  Measurement of lower extremity kinematics during level walking , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[12]  Giancarlo Ferrigno,et al.  Elite: A Digital Dedicated Hardware System for Movement Analysis Via Real-Time TV Signal Processing , 1985, IEEE Transactions on Biomedical Engineering.