Ventilation Control Strategy Using the Supply CO2 Concentration Setpoint

This paper proposes a new ventilation control strategy applied to multiple spaces subject to variable occupancy. The strategy specified for real-time, online ventilation control takes advantage of uninitiated air from some overventilated spaces to be used as fresh outdoor air in order to reduce system energy use while maintaining the indoor air quality (IAQ) in each space. This proposed strategy maintains a supply CO2 concentration setpoint low enough to dilute CO2 generated by full occupancy in critical zones. The supply CO2 concentration setpoint could be determined online using the monitored zone airflow rates. It is tested and evaluated by making comparisons with other known control strategies. An existing VAV system installed at the École de technologie supérieure is used to evaluate this new strategy. The outdoor air fraction and associated energy use of investigated ventilation control strategies are calculated using the VAV system component models that are developed and validated against the monitored data.

[1]  Ya-hui Ke,et al.  98/00674 Optimized supply-air temperature (SAT) in variable air-volume (VAV) systems , 1997 .

[2]  Mike Schell Saving energy and optimizing air quality using carbon dioxide (CO2) , 1998 .

[3]  Yu-Pei Ke,et al.  Variable air volume ventilation control strategies analysed in six climate zones , 1999 .

[4]  Michael J. Title Algorithms Brandemuehl,et al.  HVAC 2 toolkit : a toolkit for secondary HVAC system energy calculations , 1993 .

[5]  Shengwei Wang,et al.  CO2-Based Occupancy Detection for On-Line Outdoor Air Flow Control , 1998, Indoor and Built Environment.

[6]  C. G. Nesler,et al.  Strategies for outdoor airflow control from a systems perspective , 1995 .

[7]  Stanislaw Kajl,et al.  MODELING AND VALIDATION OF EXISTING VAV SYSTEM COMPONENTS , 2004 .

[8]  Vice President,et al.  AMERICAN SOCIETY OF HEATING, REFRIGERATION AND AIR CONDITIONING ENGINEERS INC. , 2007 .

[9]  Shengwei Wang,et al.  A robust control strategy for combining DCV control with economizer control , 2002 .

[10]  Shengwei Wang,et al.  CO 2-Based Occupancy Detection for On-Line Outdoor Air Flow Control , 1998 .

[11]  Andrew K. Persily Ventilation, carbon dioxide and ASHRAE standard 62-1989 , 1993 .

[12]  Robert Sabourin,et al.  Two-objective on-line optimization of supervisory control strategy , 2004 .

[13]  David E. Claridge,et al.  A study of energy use and satisfactory zone ventilation of different outdoor air ventilation strategies for terminal reheat variable air volume systems , 1998 .

[14]  John Kettler Standard 62's Multiple Spaces Equation: For Design, Not Control , 2003 .