A Dual-Function Instantaneous Power Theory for Operation of Three-Level Neutral-Point-Clamped Inverter-Based Shunt Active Power Filter

This paper proposes a simple yet effective reference current generation algorithm based on instantaneous power p q theory to enhance mitigation performance of a three-phase three-level neutral-point-clamped (NPC) inverter-based shunt active power filter (SAPF). The proposed algorithm is developed for dual functionality: generate reference current and synchronization phase to effectively govern operation of SAPF in mitigating harmonic current and compensating reactive power. Three key modifications are implemented: (1) replacement of numerical low-pass filter (LPF) with an average power detector to improve mitigation performance; (2) removal of needless reactive element to reduce algorithm complexity; and (3) integration of phase tracking feature to eliminate the needs of phase-locked loop (PLL). Simulation work of SAPF with the proposed algorithm was conducted and assessed in MATLAB–Simulink. In addition, to verify feasibility of the proposed algorithm, a laboratory prototype as constructed with TMS320F28335 digital signal processor (DSP) programmed as the controller. Performance of SAPF achieved by utilizing the proposed algorithm was thoroughly investigated and benchmarked with that demonstrated using the existing p q theory algorithm to evaluate the inherent advantages. Simulation and experimental results are obtained for different nonlinear loads and test conditions. Responses demonstrated by SAPF in both simulation and experimental works reveal superiority of the proposed algorithm over the existing algorithm.

[1]  Chi-Seng Lam,et al.  Unbalanced Control Strategy for A Thyristor-Controlled LC-Coupling Hybrid Active Power Filter in Three-Phase Three-Wire Systems , 2017, IEEE Transactions on Power Electronics.

[2]  Josep M. Guerrero,et al.  A New Synchronous Reference Frame-Based Method for Single-Phase Shunt Active Power Filters , 2013 .

[3]  Leonardo Bruno Garcia Campanhol,et al.  Application of shunt active power filter for harmonic reduction and reactive power compensation in three-phase four-wire systems , 2014 .

[4]  Mohd Amran Mohd Radzi,et al.  DC-Link Capacitor Voltage Regulation for Three-Phase Three-Level Inverter-Based Shunt Active Power Filter with Inverted Error Deviation Control , 2016 .

[5]  Krishna Busawon,et al.  Fast-individual-harmonic-extraction technique , 2005 .

[6]  Patricio Salmerón,et al.  Instantaneous Reactive Power Theory Applied to Active Power Filter Compensation: Different Approaches, Assessment, and Experimental Results , 2008, IEEE Transactions on Industrial Electronics.

[7]  A. Pigazo,et al.  A Recursive Park Transformation to Improve the Performance of Synchronous Reference Frame Controllers in Shunt Active Power Filters , 2009, IEEE Transactions on Power Electronics.

[8]  O. Vodyakho,et al.  Three-Level Inverter-Based Shunt Active Power Filter in Three-Phase Three-Wire and Four-Wire Systems , 2009, IEEE Transactions on Power Electronics.

[9]  D. Boroyevich,et al.  Decoupled Double Synchronous Reference Frame PLL for Power Converters Control , 2007, IEEE Transactions on Power Electronics.

[10]  T. Kulworawanichpong,et al.  The DQ Axis With Fourier (DQF) Method for Harmonic Identification , 2007, IEEE Transactions on Power Delivery.

[11]  K.H. Bhalodi,et al.  Space Vector Modulation with DC-Link Voltage Balancing Control for Three-Level Inverters , 2006, 2006 International Conference on Power Electronic, Drives and Energy Systems.

[12]  S. Leva,et al.  Evaluation of line voltage drop in presence of unbalance, harmonics, and interharmonics: Theory and applications , 2005, IEEE Transactions on Power Delivery.

[13]  Patrice Wira,et al.  A Unified Artificial Neural Network Architecture for Active Power Filters , 2007, IEEE Transactions on Industrial Electronics.

[14]  Hui Wang,et al.  Investigation on a New Algorithm for Instantaneous Reactive and Harmonic Currents Detection Applied to Intensive Nonlinear Loads , 2007, IEEE Transactions on Power Delivery.

[15]  Avik Bhattacharya,et al.  A Shunt Active Power Filter With Enhanced Performance Using ANN-Based Predictive and Adaptive Controllers , 2011, IEEE Transactions on Industrial Electronics.

[16]  Chi-Seng Lam,et al.  Analysis of DC-Link Voltage Controls in Three-Phase Four-Wire Hybrid Active Power Filters , 2013, IEEE Transactions on Power Electronics.

[17]  Shahrokh Farhangi,et al.  Improvement of Dynamic Behavior of Shunt Active Power Filter Using Fuzzy Instantaneous Power Theory , 2014 .

[18]  F. Blaabjerg,et al.  Detection is key - Harmonic detection methods for active power filter applications , 2007, IEEE Industry Applications Magazine.

[19]  Nashiren Farzilah Mailah,et al.  DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter , 2017 .

[20]  Xu Wang,et al.  Control Techniques for Active Power Filters , 2010, 2010 International Conference on Electrical and Control Engineering.

[21]  R. Chudamani,et al.  Non-linear least-squares-based harmonic estimation algorithm for a shunt active power filter , 2009 .

[22]  Mohd Amran Mohd Radzi,et al.  Modified Synchronous Reference Frame Based Shunt Active Power Filter with Fuzzy Logic Control Pulse Width Modulation Inverter , 2017 .

[23]  Hirofumi Akagi,et al.  Active Harmonic Filters , 2005, Proceedings of the IEEE.

[24]  Murat Kale,et al.  An adaptive hysteresis band current controller for shunt active power filter , 2005 .

[25]  Alexandru Bitoleanu,et al.  A DSP-Based Implementation of the p-q Theory in Active Power Filtering Under Nonideal Voltage Conditions , 2013, IEEE Transactions on Industrial Informatics.