The performance of electroencephalogram bispectral index and auditory evoked potential index to predict loss of consciousness during propofol infusion.

UNLABELLED The bispectral index (BIS) of the electroencephalogram and middle latency auditory evoked potentials are likely candidates to measure the level of unconsciousness and, thus, may improve the early recovery profile. We prospectively investigated the predictive performance of both measures to distinguish between the conscious and unconscious state. Twelve patients undergoing lower limb orthopedic surgery during regional anesthesia additionally received propofol by target-controlled infusion for sedation. The electroencephalogram BIS and the auditory evoked potential index (AEPi), a mathematical derivative of the morphology of the auditory evoked potential waveform, were recorded simultaneously in all patients during repeated transitions from consciousness to unconsciousness. Logistic regression procedures, receiver operating characteristic analysis, and sensitivity and specificity were used to compare predictive ability of both indices. In the logistic regression models, both the BIS and AEPi were significant predictors of unconsciousness (P < 0.0001). The area under the receiver operating characteristic curve for discrete descending index threshold values was apparently, but not significantly (P > 0.05), larger for the AEPi (0.968) than for the BIS (0.922), indicating a trend of better discriminatory performance. We conclude that both the BIS and AEPi are reliable means for monitoring the level of unconsciousness during propofol infusion. However, AEPi proved to offer more discriminatory power in the individual patient. IMPLICATIONS Both the bispectral index of the electroencephalogram and the auditory evoked potentials index are good predictors of the level of sedation and unconsciousness during propofol infusion. However, the auditory evoked potentials index offers better discriminatory power in describing the transition from the conscious to the unconscious state in the individual patient.

[1]  C. Metz,et al.  Maximum likelihood estimation of receiver operating characteristic (ROC) curves from continuously-distributed data. , 1998, Statistics in medicine.

[2]  L. Kearse,et al.  Bispectral Analysis of the Electroencephalogram Predicts Conscious Processing of Information during Propofol Sedation and Hypnosis , 1998, Anesthesiology.

[3]  Jin Liu,et al.  Electroencephalographic Bispectral Index Correlates with Intraoperative Recall and Depth of Propofol-Induced Sedation , 1997, Anesthesia and analgesia.

[4]  N. T. Smith,et al.  A measure of association for assessing prediction accuracy that is a generalization of non-parametric ROC area. , 1996, Statistics in medicine.

[5]  C Thornton,et al.  Evoked responses in anaesthesia. , 1998, British journal of anaesthesia.

[6]  D. Hosmer,et al.  Applied Logistic Regression , 1991 .

[7]  Warren D. Smith,et al.  Measuring the Performance of Anesthetic Depth Indicators , 1996, Anesthesiology.

[8]  Strother H. Walker,et al.  Estimation of the probability of an event as a function of several independent variables. , 1967, Biometrika.

[9]  G N Kenny,et al.  Auditory evoked potential index: a quantitative measure of changes in auditory evoked potentials during general anaesthesia , 1997, Anaesthesia.

[10]  Jeffrey C. Sigl,et al.  The Effect of the Interaction of Propofol and Alfentanil on Recall, Loss of Consciousness, and the Bispectral Index , 1998 .

[11]  M. Georgieff,et al.  Clinical utility of EEG parameters to predict loss of consciousness and response to skin incision during total intravenous anaesthesia , 1998, Anaesthesia.

[12]  G N Kenny,et al.  Relationship between calculated blood concentration of propofol and electrophysiological variables during emergence from anaesthesia: comparison of bispectral index, spectral edge frequency, median frequency and auditory evoked potential index. , 1997, British journal of anaesthesia.

[13]  N R Webster,et al.  Auditory evoked response and awareness: a study in volunteers at sub-MAC concentrations of isoflurane. , 1992, British journal of anaesthesia.

[14]  G N Kenny,et al.  Analysis of the EEG bispectrum, auditory evoked potentials and the EEG power spectrum during repeated transitions from consciousness to unconsciousness. , 1998, British journal of anaesthesia.

[15]  G N Kenny,et al.  Middle latency auditory evoked potentials during repeated transitions from consciousness to unconsciousness , 1996, Anaesthesia.

[16]  M. White,et al.  A portable target controlled propofol infusion system , 1992, International journal of clinical monitoring and computing.

[17]  Elizabeth C. Hirschman,et al.  Judgment under Uncertainty: Heuristics and Biases , 1974, Science.

[18]  W. Hauck,et al.  Wald's Test as Applied to Hypotheses in Logit Analysis , 1977 .

[19]  I. Rampil A Primer for EEG Signal Processing in Anesthesia , 1998, Anesthesiology.

[20]  J. Hanley,et al.  The meaning and use of the area under a receiver operating characteristic (ROC) curve. , 1982, Radiology.

[21]  N. T. Smith,et al.  A Multicenter Study of Bispectral Electroencephalogram Analysis for Monitoring Anesthetic Effect , 1997, Anesthesia and analgesia.

[22]  Udilo Finsterer,et al.  Midlatency Auditory Evoked Potentials Predict Movements During Anesthesia with Isoflurane or Propofol , 1997, Anesthesia and analgesia.