Interfractional anatomic variation in patients treated with respiration‐gated radiotherapy

As quality assurance for respiration‐gated treatments using the Varian RPM™ system, we monitor interfractional diaphragm variation throughout treatment using extra anterior‐posterior (AP) portal images. We measure the superior‐inferior (SI) distance between one or more bony landmarks and the ipsilateral diaphragm dome in each such radiograph and calculate its difference, D, from the corresponding distance in a planning CT scan digitally reconstructed radiograph (DRR). For each patient, the mean of D represents the systematic diaphragm displacement, and the standard deviation of D represents random diaphragm variations and is a measure of interfractional gating reproducibility. We present results for 31 sequential patients (21 lung, 10 liver tumors), each with at least 8 such portal images. For all patients, the gate included end‐exhale. The patient‐specific duty cycle ranged from 30% to 60%. All patients received customized audio prompting for simulation and treatment, and 14 patients also received visual prompting. Respiration‐synchronized fluoroscopic movies taken at a conventional simulator revealed patient‐specific diaphragm excursions from 1.0 cm to 5.0 cm and diaphragm excursion within the gate from 0.5 cm to 1.0 cm, demonstrating a significant reduction of intra‐fractional diaphragm (and by inference tumor) motion by respiratory gating. One standard deviation of the systematic displacement (the mean of D) was 0.63 cm and 0.48 cm for the lung and liver patient groups, respectively. The average ±1 SD of the random displacements (i.e., the average of the standard deviations of D) was 0.42±0.11 cm and 0.50±0.19 for the two groups, respectively. The similar magnitude of the systematic and random displacements suggests that both derive from a common distribution of interfractional variations. Combining visual with audio prompting did not significantly improve performance, as judged by D. Guided by these portal images, field changes were made during the course of treatment for 6 patients (1 lung, 5 liver). PACS numbers: 87.53.‐j, 87.53.Oq

[1]  H. Mostafavi,et al.  Breathing-synchronized radiotherapy program at the University of California Davis Cancer Center. , 2000, Medical physics.

[2]  C C Ling,et al.  Cone-beam CT with megavoltage beams and an amorphous silicon electronic portal imaging device: potential for verification of radiotherapy of lung cancer. , 2002, Medical physics.

[3]  M. V. van Herk,et al.  Physical aspects of a real-time tumor-tracking system for gated radiotherapy. , 2000, International journal of radiation oncology, biology, physics.

[4]  H Shirato,et al.  Detection of lung tumor movement in real-time tumor-tracking radiotherapy. , 2001, International journal of radiation oncology, biology, physics.

[5]  Andrew Jackson,et al.  Dosimetric effect of respiratory motion in external beam radiotherapy of the lung. , 2004, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[6]  K. Ohara,et al.  Irradiation synchronized with respiration gate. , 1989, International journal of radiation oncology, biology, physics.

[7]  T. Pan,et al.  4D-CT imaging of a volume influenced by respiratory motion on multi-slice CT. , 2004, Medical physics.

[8]  Martin J Murphy,et al.  Issues in respiratory motion compensation during external-beam radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[9]  C. Ling,et al.  Technical aspects of the deep inspiration breath-hold technique in the treatment of thoracic cancer. , 2000, International journal of radiation oncology, biology, physics.

[10]  Gikas S. Mageras,et al.  Fluoroscopic evaluation of diaphragmatic motion reduction with a respiratory gated radiotherapy system , 2001, Journal of applied clinical medical physics.

[11]  C. Ling,et al.  Evaluation of respiratory movement during gated radiotherapy using film and electronic portal imaging. , 2002, International journal of radiation oncology, biology, physics.

[12]  R. Mohan,et al.  Acquiring a four-dimensional computed tomography dataset using an external respiratory signal. , 2003, Physics in medicine and biology.

[13]  Harry Keller,et al.  Application of the spirometer in respiratory gated radiotherapy. , 2003, Medical physics.

[14]  Koichi Yamazaki,et al.  Feasibility of insertion/implantation of 2.0-mm-diameter gold internal fiducial markers for precise setup and real-time tumor tracking in radiotherapy. , 2003, International journal of radiation oncology, biology, physics.

[15]  Paul J. Keall,et al.  A dynamic non-invasive technique for predicting organ motion in respiratory-gated radiotherapy of the chest , 2001 .

[16]  C. Ling,et al.  Respiration-correlated spiral CT: a method of measuring respiratory-induced anatomic motion for radiation treatment planning. , 2002, Medical physics.

[17]  Joos V Lebesque,et al.  Portal imaging to assess set-up errors, tumor motion and tumor shrinkage during conformal radiotherapy of non-small cell lung cancer. , 2001, Radiotherapy and Oncology.

[18]  J. Wong,et al.  Flat-panel cone-beam computed tomography for image-guided radiation therapy. , 2002, International journal of radiation oncology, biology, physics.

[19]  C C Ling,et al.  The deep inspiration breath-hold technique in the treatment of inoperable non-small-cell lung cancer. , 2000, International journal of radiation oncology, biology, physics.

[20]  G. Christensen,et al.  A method for the reconstruction of four-dimensional synchronized CT scans acquired during free breathing. , 2003, Medical physics.

[21]  James M Balter,et al.  Daily targeting of intrahepatic tumors for radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[22]  R Mohan,et al.  Determining parameters for respiration-gated radiotherapy. , 2001, Medical physics.

[23]  T Kozuka,et al.  Lung cancer: intermittent irradiation synchronized with respiratory motion--results of a pilot study. , 1998, Radiology.

[24]  E. Yorke,et al.  Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatment. , 2004, Seminars in radiation oncology.

[25]  J. Fowler,et al.  Image guidance for precise conformal radiotherapy. , 2003, International journal of radiation oncology, biology, physics.

[26]  K. Brock,et al.  Determination of ventilatory liver movement via radiographic evaluation of diaphragm position. , 2001, International journal of radiation oncology, biology, physics.

[27]  Tinsu Pan,et al.  4D computed tomography for treatment planning , 2003 .

[28]  C. Ramsey,et al.  A comparison of beam characteristics for gated and nongated clinical x-ray beams. , 1999, Medical physics.

[29]  E. Yorke,et al.  Respiratory gating for liver tumors: Use in dose escalation , 2003 .

[30]  Eric C Ford,et al.  Measurement of lung tumor motion using respiration-correlated CT. , 2004, International journal of radiation oncology, biology, physics.

[31]  K. Langen,et al.  Organ motion and its management. , 2001, International journal of radiation oncology, biology, physics.

[32]  Radhe Mohan,et al.  Patient training in respiratory-gated radiotherapy. , 2003, Medical dosimetry : official journal of the American Association of Medical Dosimetrists.

[33]  Randall K Ten Haken,et al.  Daily prostate targeting using implanted radiopaque markers. , 2001, International journal of radiation oncology, biology, physics.

[34]  H. Kubo,et al.  Respiration gated radiotherapy treatment: a technical study. , 1996, Physics in medicine and biology.

[35]  R. Mohan,et al.  Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker. , 2003, Medical physics.

[36]  G Starkschall,et al.  Respiratory-driven lung tumor motion is independent of tumor size, tumor location, and pulmonary function. , 2001, International journal of radiation oncology, biology, physics.