In Vivo Evaluation of Quantitative MR Angiography in a Canine Carotid Artery Stenosis Model

BACKGROUND AND PURPOSE: Large-vessel cerebral blood flow quantification has emerged as a potential predictor of stroke risk. QMRA uses phase-contrast techniques to noninvasively measure vessel flows. To evaluate the in vivo accuracy of QMRA for measuring the effects of progressive arterial stenosis, we compared this technique with invasive flow measurements from a sonographic transit-time flow probe in a canine model. MATERIALS AND METHODS: A sonographic flow probe was implanted around the CCA of hound dogs (n = 4) under general anesthesia. Pulsatile blood flow and arterial pressure were continuously recorded during CCA flow measurements with QMRA. A vascular tourniquet was applied around the CCA to produce progressive stenosis and varying flow rates. Statistical comparisons were made by using the Pearson product moment correlation coefficient. RESULTS: A total of 60 paired CCA flow measurements were compared. Mean blood flows ranged between 21 and 691 mL/min during QMRA acquisition as measured by the flow probe. The correlation coefficients between flow probe and QMRA measurements for mean, maximum, and minimum volume flow rates were 0.99 (P < .0001), 0.98 (P < .0001), and 0.96 (P < .0001), respectively. The overall proportional difference between the 2 techniques was 7.8 ± 1%. Measurements at higher flow rates and in the absence of arterial stenosis had the lowest PD. CONCLUSIONS: Noninvasive CCA flow measurements by using QMRA are accurate compared with invasive flow-probe measurements in a canine arterial flow model with stenosis and may be useful for the evaluation of the hemodynamic effects of stenosis caused by cerebrovascular atherosclerosis.

[1]  N Alperin,et al.  Improved phase-contrast flow quantification by three-dimensional vessel localization. , 2000, Magnetic resonance imaging.

[2]  The evolving role of transcranial doppler in stroke prevention and treatment. , 1998, Journal of stroke and cerebrovascular diseases : the official journal of National Stroke Association.

[3]  J. Whitworth,et al.  Validation of transonic small animal flowmeter for measurement of cardiac output and regional blood flow in the rat. , 1996, Journal of cardiovascular pharmacology.

[4]  D. Parker,et al.  Accuracy of phase‐contrast flow measurements in the presence of partial‐volume effects , 1993, Journal of magnetic resonance imaging : JMRI.

[5]  J. Tukey,et al.  Variations of Box Plots , 1978 .

[6]  C Mistretta,et al.  Physiologic and anatomic assessment of a canine carotid artery stenosis model utilizing phase contrast with vastly undersampled isotropic projection imaging. , 2007, AJNR. American journal of neuroradiology.

[7]  J. Hendrikse,et al.  Distribution of cerebral blood flow in the circle of Willis. , 2005, Radiology.

[8]  P C Jackson,et al.  An evaluation of the accuracy of flow measurements using magnetic resonance imaging (MRI). , 1991, Journal of medical engineering & technology.

[9]  J. Gore,et al.  Mapping of turbulent intensity by magnetic resonance imaging. , 1994, Journal of Magnetic Resonance - Series B.

[10]  H. Yonas,et al.  Advanced CT imaging (functional CT). , 1999, Neuroimaging clinics of North America.

[11]  T. Grist,et al.  Vasodilatory Responses and Magnetic Resonance Angiography , 1997, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[12]  O Henriksen,et al.  Quantification of complex flow using MR phase imaging--a study of parameters influencing the phase/velocity relation. , 1992, Magnetic resonance imaging.

[13]  Christof Karmonik,et al.  Quantitative Segmentation of Principal Carotid Atherosclerotic Lesion Components by Feature Space Analysis Based on Multicontrast MRI at 1.5 T , 2009, IEEE Transactions on Biomedical Engineering.

[14]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[15]  Nico Westerhof,et al.  In Vivo Validation of Magnetic Resonance Blood Volume Flow Measurements with Limited Spatial Resolution in Small Vessels , 1995, Magnetic resonance in medicine.

[16]  T. Wada,et al.  Correlation of common carotid flow volume measured by ultrasonic quantitative flowmeter with pathological findings. , 1991, Stroke.

[17]  R. Pettigrew,et al.  Quantitative phase-flow MR imaging in dogs by using standard sequences: comparison with in vivo flow-meter measurements. , 1987, AJR. American journal of roentgenology.

[18]  S. Prabhakaran,et al.  The Utility of Quantitative Magnetic Resonance Angiography in the Assessment of Intracranial In-Stent Stenosis , 2009, Stroke.

[19]  S. Amin-Hanjani,et al.  Regional Cerebral Blood Flow Using Quantitative MR Angiography , 2007, American Journal of Neuroradiology.

[20]  J. Thiran,et al.  Simultaneous measurement of regional cerebral blood flow by perfusion CT and stable xenon CT: a validation study. , 2001, AJNR. American journal of neuroradiology.

[21]  M Misra,et al.  Ultrasonic perivascular flow probe: technique and application in neurosurgery. , 1998, Neurological research.

[22]  G. V. von Schulthess,et al.  Aortic valve pressure gradients in patients with aortic valve stenosis: quantification with velocity-encoded cine MR imaging. , 1993, AJR. American journal of roentgenology.

[23]  F. Charbel,et al.  Use of Quantitative Magnetic Resonance Angiography to Stratify Stroke Risk in Symptomatic Vertebrobasilar Disease , 2005, Stroke.

[24]  D Comar,et al.  Regional Cerebral Blood Flow and Oxygen Consumption in Human Aging , 1984, Stroke.

[25]  Hans-Ulrich Kauczor,et al.  Validation of Magnetic Resonance Phase-Contrast Flow Measurements in the Main Pulmonary Artery and Aorta Using Perivascular Ultrasound in a Large Animal Model , 2008, Investigative radiology.

[26]  G. Donnan,et al.  Rapid Assessment of Perfusion–Diffusion Mismatch , 2008, Stroke.

[27]  S. Amin-Hanjani,et al.  Flow-assisted surgical cerebral revascularization. , 2008, Neurosurgical focus.

[28]  R. Kim,et al.  Noninvasive Assessment of Blood Flow Based on Magnetic Resonance Global Coherent Free Precession , 2005, Circulation.

[29]  L. G. Myers,et al.  Clinical Cerebrovascular Applications of Arterial Ultrasound Volume Flow Rate Estimates , 1996, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[30]  Takashi Yoshimoto,et al.  Cerebrovascular Reactivity to Acetazolamide and Outcome in Patients With Symptomatic Internal Carotid or Middle Cerebral Artery Occlusion: A Xenon-133 Single-Photon Emission Computed Tomography Study , 2002, Stroke.

[31]  O Wieben,et al.  Noninvasive Measurement of Intra-Aneurysmal Pressure and Flow Pattern Using Phase Contrast with Vastly Undersampled Isotropic Projection Imaging , 2007, American Journal of Neuroradiology.

[32]  B. Cowan,et al.  MRI phase contrast velocity and flow errors in turbulent stenotic jets , 2008, Journal of magnetic resonance imaging : JMRI.

[33]  H. Okano,et al.  Possible Oncogenicity of Subventricular Zone Neural Stem Cells: Case Report , 2004, Neurosurgery.

[34]  S. Amin-Hanjani,et al.  Quantitative Magnetic Resonance Angiography in the Evaluation of the Subclavian Steal Syndrome: Report of 5 Patients , 2009, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[35]  Mohammad Mehdi Eskandari,et al.  Use of Quantitative Magnetic Resonance Angiography to Stratify Stroke Risk in Symptomatic Vertebrobasilar DiseaseAmin-Hanjani S, Du X, Zhao M, et al (Univ of Illinois at Chicago) Stroke 36:1140–1145, 2005§ , 2007 .

[36]  S. Amin-Hanjani,et al.  The Cut Flow Index: An Intraoperative Predictor of the Success of Extracranial-Intracranial Bypass for Occlusive Cerebrovascular Disease , 2005, Neurosurgery.

[37]  F. Korosec,et al.  PC VIPR: a high-speed 3D phase-contrast method for flow quantification and high-resolution angiography. , 2005, AJNR. American journal of neuroradiology.

[38]  N J Pelc,et al.  Arterial and venous blood flow: noninvasive quantitation with MR imaging. , 1992, Radiology.

[39]  Fady T Charbel,et al.  The Utility of Intraoperative Blood Flow Measurement During Aneurysm Surgery Using an Ultrasonic Perivascular Flow Probe , 2006, Neurosurgery.

[40]  C Karmonik,et al.  Blood Flow in Cerebral Aneurysms: Comparison of Phase Contrast Magnetic Resonance and Computational Fluid Dynamics - Preliminary Experience , 2008, RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin.

[41]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[42]  M. E. Clark,et al.  A patient-specific computer model to predict outcomes of the balloon occlusion test. , 2004, Journal of neurosurgery.

[43]  S. Amin-Hanjani,et al.  Leptomeningeal Collateral Volume Flow Assessed by Quantitative Magnetic Resonance Angiography in Large‐Vessel Cerebrovascular Disease , 2009, Journal of neuroimaging : official journal of the American Society of Neuroimaging.

[44]  H. Mäkisalo,et al.  Validity and reproducibility of transit time flowmetry. , 1996, Annales chirurgiae et gynaecologiae.

[45]  Charles A Mistretta,et al.  Transstenotic pressure gradients: measurement in swine--retrospectively ECG-gated 3D phase-contrast MR angiography versus endovascular pressure-sensing guidewires. , 2007, Radiology.

[46]  Amir A Amini,et al.  Factors affecting the accuracy of pressure measurements in vascular stenoses from phase‐contrast MRI , 2004, Magnetic resonance in medicine.

[47]  S. Amin-Hanjani,et al.  Evaluation of extracranial-intracranial bypass using quantitative magnetic resonance angiography. , 2007, Journal of neurosurgery.