A statistical study of the factors influencing the extent of respiratory motion blur in PET imaging

Respiratory motion results in significant motion blur in thoracic and abdomen PET imaging. The extent of respiratory motion blur is mainly correlated with breathing amplitude, tumor size and location. In this paper we introduce a statistical study to quantitatively show the factors influencing the extent of respiratory motion blur in thoracic PET images. The study is centered on two regression models, one is linked with motion blur induced loss of mean intensity(LMI), tumor motion magnitude and tumor size, and another is to investigate the influence of tumor location, patient gender and patient height on tumor motion magnitude. We use the blur identification and image restoration technique to estimate the tumor motion and compute the LMI. The regression model was validated by simulation and phantom data before extended to 39 cases of clinical lung tumor PET images corrupted with blurring artifact. Results show that the motion magnitude of lung tumor during breathing is 10.9±3.7mm in transaxial plane, and it is significantly greater in lower lung lobes than in upper lobes. The LMI is 7.1±2.4% in the region of interest (ROI) above 40% of the image's maximum intensity. The least-square estimate of regression equations demonstrates that LMI is proportional to tumor motion magnitude and is inversely proportional to tumor size; the two factors play the same role in determining the extent of respiratory motion blur in thoraco-abdominal PET imaging. The location of tumor was shown as the major factor determining its motion magnitude, while the influencing of patient gender and height on tumor motion was not shown significant.

[1]  C. Ling,et al.  Effect of respiratory gating on reducing lung motion artifacts in PET imaging of lung cancer. , 2002, Medical physics.

[2]  Yitzhak Yitzhaky,et al.  Identification of blur parameters from motion-blurred images , 1996, Optics & Photonics.

[3]  J. Machac,et al.  Improving 3D PET imaging by restoration: a phantom study. , 2005, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[4]  A. Pevsner,et al.  Quantitation of respiratory motion during 4D-PET/CT acquisition. , 2004, Medical physics.

[5]  John W. Clark,et al.  A motion-incorporated reconstruction method for gated PET studies , 2006, Physics in medicine and biology.

[6]  A. Pevsner,et al.  The CT motion quantitation of lung lesions and its impact on PET-measured SUVs. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[7]  R. Mohan,et al.  Quantifying the predictability of diaphragm motion during respiration with a noninvasive external marker. , 2003, Medical physics.

[8]  D. A. Fish,et al.  Blind deconvolution by means of the Richardson-Lucy algorithm. , 1995 .

[9]  J. Drèze,et al.  Specification and estimation of Cobb-Douglas production function models , 1966 .

[10]  R. Lecomte,et al.  Respiratory gating for 3-dimensional PET of the thorax: feasibility and initial results. , 2004, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[11]  D. Visvikis,et al.  Respiratory motion in positron emission tomography for oncology applications: Problems and solutions , 2006 .

[12]  Yitzhak Yitzhaky,et al.  Initialization of iterative parametric algorithms for blind deconvolution of motion-blurred images. , 2006, Applied optics.

[13]  Reduction of motion artifacts for PET imaging by respiratory correlated dynamic scanning , 2006 .

[14]  M. V. van Herk,et al.  Precise and real-time measurement of 3D tumor motion in lung due to breathing and heartbeat, measured during radiotherapy. , 2002, International journal of radiation oncology, biology, physics.

[15]  John W. Clark,et al.  Implementation of an Automated Respiratory Amplitude Gating Technique for PET/CT: Clinical Evaluation , 2010, Journal of Nuclear Medicine.

[16]  J. MacKinnon,et al.  Econometric Theory and Methods , 2003 .

[17]  Doumit Daou,et al.  Respiratory motion handling is mandatory to accomplish the high-resolution PET destiny , 2008, European Journal of Nuclear Medicine and Molecular Imaging.

[18]  Kehong Yuan,et al.  Respiratory motion blur identification and reduction in ungated thoracic PET imaging , 2011, Physics in medicine and biology.

[19]  Xiaoyi Jiang,et al.  Respiratory Motion Correction in 3-D PET Data With Advanced Optical Flow Algorithms , 2008, IEEE Transactions on Medical Imaging.

[20]  Jiali Wang,et al.  Computer-assisted quantification of lung tumors in respiratory gated PET/CT images: phantom study , 2009, Medical & Biological Engineering & Computing.

[21]  Joseph O Deasy,et al.  Deblurring of breathing motion artifacts in thoracic PET images by deconvolution methods. , 2006, Medical physics.

[22]  N S Kopeika,et al.  Comparison of direct blind deconvolution methods for motion-blurred images. , 1999, Applied optics.

[23]  H. Zaidi,et al.  Assessment of various strategies for 18F-FET PET-guided delineation of target volumes in high-grade glioma patients , 2009, European Journal of Nuclear Medicine and Molecular Imaging.

[24]  Yitzhak Yitzhaky,et al.  Restoration of an image degraded by vibrations using only a single frame , 2000 .

[25]  Steve B. Jiang,et al.  The management of respiratory motion in radiation oncology report of AAPM Task Group 76. , 2006, Medical physics.

[26]  Dan Arbel,et al.  Medical image restoration of dynamic lungs using optical transfer function of lung motion , 1995, Optics & Photonics.