Electrochemical DNA biosensor for the detection and discrimination of herpes simplex Type I and Type II viruses from PCR amplified real samples

An electrochemical biosensor for the voltammetric detection of DNA sequences related to herpes simplex viruses (HSV) and discrimination of HSV Type I and Type II viruses from polymerase chain reaction (PCR) amplified real samples were described in this study. The biosensor relies on the covalent immobilization of the 22-mer single stranded oligonucleotides (probe) related to both HSV Type I and Type II sequences and hybridization of these oligonucleotides with their complementary and four bases mismatch containing (four bases MM) sequences at pencil graphite electrodes (PEGE). The extent of hybridization between probe and target sequences was determined by using differential pulse voltammetry (DPV) and Meldola Blue (MDB) was used as the hybridization indicator. As a result of the interaction between MDB and DNA at PEGE surface, the MDB signal observed from probe sequence before hybridization and after hybridization with four bases MM sequence is lower than that observed after hybridization with complementary sequence. The difference between the MDB signals obtained from probe modified, hybrid modified and four bases MM modified PEGE were used to detect and discriminate two types of HSV from PCR amplified real samples. Numerous factors affecting the target hybridization and indicator binding reactions are optimized to maximize the sensitivity.

[1]  J Wang,et al.  DNA electrochemical biosensor for the detection of short DNA sequences related to the human immunodeficiency virus. , 1996, Analytical chemistry.

[2]  Marco Mascini,et al.  Electrochemical DNA biosensor for the detection of TT and Hepatitis B virus from PCR amplified real samples by using methylene blue. , 2002, Talanta.

[3]  Yoshio Ishimori,et al.  Novel DNA sensor for electrochemical gene detection , 1994 .

[4]  B. Limoges,et al.  Hybridization assay at a disposable electrochemical biosensor for the attomole detection of amplified human cytomegalovirus DNA. , 2000, Analytical biochemistry.

[5]  Joseph Wang,et al.  Towards Genoelectronics: Electrochemical Biosensing of DNA Hybridization , 1999 .

[6]  Joseph Wang Electrochemical nucleic acid biosensors , 2002 .

[7]  G. R. Taylor,et al.  PCR: a practical approach. , 1991 .

[8]  K. M. Millan,et al.  Sequence-selective biosensor for DNA based on electroactive hybridization indicators. , 1993, Analytical chemistry.

[9]  Kagan Kerman,et al.  DNA Electrochemical Biosensor for the Detection of Short DNA Sequences Related to the Hepatitis B Virus , 1999 .

[10]  John S. McLean,et al.  Electrochemical detection of secreted alkaline phosphatase: implications to cell based assays , 2000 .

[11]  I Karube,et al.  Detection of PCR products in solution using surface plasmon resonance. , 1999, Analytical chemistry.

[12]  Z. Loewy,et al.  Polymerase Chain Reaction and Its Use in Diagnostics , 1993 .

[13]  R. Yolken,et al.  Herpesviruses and Toxoplasma gondii in orbital frontal cortex of psychiatric patients , 2003, Schizophrenia Research.

[14]  Susan R. Mikkelsen,et al.  Electrochecmical biosensors for DNA sequence detection , 1996 .

[15]  G. Marrazza,et al.  Carbon and gold electrodes as electrochemical transducers for DNA hybridisation sensors. , 2004, Biosensors & bioelectronics.

[16]  Harry L. Arnold,et al.  American Academy of Dermatology , 1980 .

[17]  K. M. Millan,et al.  Voltammetric DNA biosensor for cystic fibrosis based on a modified carbon paste electrode. , 1994, Analytical chemistry.

[18]  Gustavo Rivas,et al.  Stripping potentiometric transduction of DNA hybridization processes , 1996 .

[19]  Joseph Wang,et al.  Screen‐printed electrochemical hybridization biosensor for the detection of DNA sequences from the Escherichia coli pathogen , 1997 .

[20]  Prithipal Singh,et al.  Diagnostics in the Year 2000: Antibody, Biosensor, and Nucleic Acid Technologies , 1993 .

[21]  D. Pang,et al.  Interactions of benzyl viologen with surface-bound single- and double-stranded DNA. , 2000, Analytical chemistry.

[22]  A. Eckhardt,et al.  Probing biomolecule recognition with electron transfer: electrochemical sensors for DNA hybridization. , 1997, Bioconjugate chemistry.

[23]  M. A. Day,et al.  Femtosecond electron-transfer reactions in mono- and polynucleotides and in DNA. , 2002, Journal of the American Chemical Society.

[24]  K. Kerman,et al.  Detection of Interaction Between Metal Complex Indicator and DNA by Using Electrochemical Biosensor , 1999 .

[25]  H. Ju,et al.  Hybridization biosensor using di(2,2'-bipyridine)osmium (III) as electrochemical indicator for detection of polymerase chain reaction product of hepatitis B virus DNA. , 2003, Analytical biochemistry.

[26]  Gustavo Rivas,et al.  Sequence-specific electrochemical biosensing of M. tuberculosis DNA , 1997 .