A head-mounted operating binocular for augmented reality visualization in medicine - design and initial evaluation

Computer-aided surgery (CAS), the intraoperative application of biomedical visualization techniques, appears to be one of the most promising fields of application for augmented reality (AR), the display of additional computer-generated graphics over a real-world scene. Typically a device such as a head-mounted display (HMD) is used for AR. However, considerable technical problems connected with AR have limited the intraoperative application of HMDs up to now. One of the difficulties in using HMDs is the requirement for a common optical focal plane for both the realworld scene and the computer-generated image, and acceptance of the HMD by the user in a surgical environment. In order to increase the clinical acceptance of AR, we have adapted the Varioscope (Life Optics, Vienna), a miniature, cost-effective head-mounted operating binocular, for AR. In this paper, we present the basic design of the modified HMD, and the method and results of an extensive laboratory study for photogrammetric calibration of the Varioscope's computer displays to a real-world scene. In a series of 16 calibrations with varying zoom factors and object distances, mean calibration error was found to be 1.24 /spl plusmn/ 0.38 pixels or 0.12 /spl plusmn/ 0.05 mm for a 640 /spl times/ 480 display. Maximum error accounted for 3.33 /spl plusmn/ 1.04 pixels or 0.33 /spl plusmn/ 0.12 mm. The location of a position measurement probe of an optical tracking system was transformed to the display with an error of less than 1 mm in the real world in 56% of all cases. For the remaining cases, error was below 2 mm. We conclude that the accuracy achieved in our experiments is sufficient for a wide range of CAS applications.

[1]  S. James Zinreich,et al.  An optical 3D digitizer for frameless stereotactic surgery , 1996, IEEE Computer Graphics and Applications.

[2]  Wolfgang Birkfellner,et al.  Stereoscopic visualization in the varioscope AR: a see-through head-mounted display for surgical navigation , 2002, SPIE Medical Imaging.

[3]  K. Spring Euler parameters and the use of quaternion algebra in the manipulation of finite rotations: A review , 1986 .

[4]  Benjamin Watson,et al.  Using texture maps to correct for optical distortion in head-mounted displays , 1995, Proceedings Virtual Reality Annual International Symposium '95.

[5]  Jay B. West,et al.  Predicting error in rigid-body point-based registration , 1998, IEEE Transactions on Medical Imaging.

[6]  Ronald Azuma,et al.  A Survey of Augmented Reality , 1997, Presence: Teleoperators & Virtual Environments.

[7]  Wolfgang Birkfellner,et al.  A modular software system for computer-aided surgery and its first application in oral implantology , 2000, IEEE Transactions on Medical Imaging.

[8]  H Bergmann,et al.  Positioning of dental implants using computer-aided navigation and an optical tracking system: case report and presentation of a new method. , 1999, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[9]  Roger Y. Tsai,et al.  A versatile camera calibration technique for high-accuracy 3D machine vision metrology using off-the-shelf TV cameras and lenses , 1987, IEEE J. Robotics Autom..

[10]  W Birkfellner,et al.  Computer-aided surgery in distraction osteogenesis of the maxilla and mandible. , 1999, International journal of oral and maxillofacial surgery.

[11]  David J. Hawkes,et al.  Design and evaluation of a system for microscope-assisted guided interventions (MAGI) , 2000 .

[12]  Torsten Rohlfing,et al.  Augmented-reality visualization of brain structures with stereo and kinetic depth cues: system description and initial evaluation with head phantom , 2001, SPIE Medical Imaging.

[13]  Wolfgang Birkfellner,et al.  Calibration of tracking systems in a surgical environment , 1998, IEEE Transactions on Medical Imaging.

[14]  H Bergmann,et al.  In-vitro assessment of a registration protocol for image guided implant dentistry. , 2001, Clinical oral implants research.

[15]  S Bangay,et al.  An investigation into factors influencing immersion in interactive virtual reality environments. , 1998, Studies in health technology and informatics.

[16]  R. Meals,et al.  A practical guide to surgical loupes. , 1997, The Journal of hand surgery.

[17]  John K. Ousterhout,et al.  Tcl and the Tk Toolkit , 1994 .

[18]  H Bergmann,et al.  Placement of Endosteal Implants in the Zygoma after Maxillectomy: A Cadaver Study Using Surgical Navigation , 2001, Plastic and reconstructive surgery.

[19]  Reg G. Willson Modeling and calibration of automated zoom lenses , 1994, Other Conferences.

[20]  Berthold K. P. Horn,et al.  Closed-form solution of absolute orientation using unit quaternions , 1987 .