Improved activation maps via the elimination of motion effects through time‐domain mixing of data in conventional gradient echo functional MRI

To date, most functional imaging centers have relied on ultra‐fast imaging approaches such as echo‐planar imaging (EPI) techniques for acquiring functional brain activation data. These methods require specialized hardware and are not yet installed widely on clinical MR imagers, thus limiting the application of functional MR imaging at many sites. EPI is used to limit motion artifacts and to collect multiple images under different task paradigms in order to distinguish reliably true signal changes from noise. However, it suffers from poor signal to noise ratio because of the high sampling bandwidth employed. This work presents an approach for increasing the efficiency of functional studies that use conventional gradient echo imaging. In this approach, small numbers of image data sets are acquired and recombined to generate composite datasets with minimized motion artifacts. The technique is introduced, and several algorithms for combining the data are explored. A receiver operator characteristic analysis and in vivo studies are performed to examine the efficacy of this approach for improving functional MR imaging studies.

[1]  Bob S. Hu,et al.  Fast Spiral Coronary Artery Imaging , 1992, Magnetic resonance in medicine.

[2]  V. Wedeen,et al.  Brain parenchyma motion: measurement with cine echo-planar MR imaging. , 1992, Radiology.

[3]  R M Henkelman,et al.  K‐space description for MR imaging of dynamic objects , 1993, Magnetic resonance in medicine.

[4]  L Axel,et al.  Respiratory effects in two-dimensional Fourier transform MR imaging. , 1986, Radiology.

[5]  Karl J. Friston,et al.  Spatial registration and normalization of images , 1995 .

[6]  J L Lancaster,et al.  Fast spin‐echo characteristics of visual stimulation‐induced signal changes in the human brain , 1995, Journal of magnetic resonance imaging : JMRI.

[7]  J Hennig,et al.  Multislice interleaved excitation cycles (MUSIC): An efficient gradient‐echo technique for functional MRI , 1996, Magnetic resonance in medicine.

[8]  J F Debatin,et al.  Cardiac echo-planar MR imaging: comparison of single- and multiple-shot techniques. , 1995, Radiology.

[9]  J. Duerk,et al.  Motion artifact suppression technique (MAST) for MR imaging. , 1987, Journal of computer assisted tomography.

[10]  E. Haacke,et al.  Identification of vascular structures as a major source of signal contrast in high resolution 2D and 3D functional activation imaging of the motor cortex at l.5T preliminary results , 1993, Magnetic resonance in medicine.

[11]  E M Haacke,et al.  Improving MR image quality in the presence of motion by using rephasing gradients. , 1987, AJR. American journal of roentgenology.

[12]  A. G. Collins,et al.  Respiratory ordered phase encoding (ROPE): a method for reducing respiratory motion artefacts in MR imaging. , 1985, Journal of computer assisted tomography.

[13]  R. Edelman,et al.  Cineangiography of the heart in a single breath hold with a segmented turboFLASH sequence. , 1991, Radiology.

[14]  R M Henkelman,et al.  A new way of averaging with applications to MRI. , 1996, Medical physics.

[15]  J C Gore,et al.  An roc approach for evaluating functional brain mr imaging and postprocessing protocols , 1995, Magnetic resonance in medicine.

[16]  M. L. Wood,et al.  MR image artifacts from periodic motion. , 1985, Medical physics.

[17]  X. Hu,et al.  Reduction of signal fluctuation in functional MRI using navigator echoes , 1994, Magnetic resonance in medicine.

[18]  J. Felmlee,et al.  Adaptive technique for high-definition MR imaging of moving structures. , 1989, Radiology.

[19]  X Hu,et al.  Retrospective estimation and correction of physiological fluctuation in functional MRI , 1995, Magnetic resonance in medicine.

[20]  C. Pelizzari,et al.  Accurate Three‐Dimensional Registration of CT, PET, and/or MR Images of the Brain , 1989, Journal of computer assisted tomography.

[21]  C. Metz Basic principles of ROC analysis. , 1978, Seminars in nuclear medicine.

[22]  G. McCarthy,et al.  Functional NMR imaging using fast spin echo at 1.5 T , 1994, Magnetic resonance in medicine.