Fibre-coupled multiphoton microscope with adaptive motion compensation.

To address the challenge of sample motion during in vivo imaging, we present a fibre-coupled multiphoton microscope with active axial motion compensation. The position of the sample surface is measured using optical coherence tomography and fed back to a piezo actuator that adjusts the axial location of the objective to compensate for sample motion. We characterise the system's performance and demonstrate that it can compensate for axial sample velocities up to 700 µm/s. Finally we illustrate the impact of motion compensation when imaging multiphoton excited autofluorescence in ex vivo mouse skin.

[1]  K. Fujita [Two-photon laser scanning fluorescence microscopy]. , 2007, Tanpakushitsu kakusan koso. Protein, nucleic acid, enzyme.

[2]  Ralph Weissleder,et al.  Automated motion artifact removal for intravital microscopy, without a priori information , 2014, Scientific Reports.

[3]  Peter Kellman,et al.  Three‐dimensional motion tracking for high‐resolution optical microscopy, in vivo , 2012, Journal of microscopy.

[4]  Francesco Saverio Pavone,et al.  In vivo non‐invasive monitoring of collagen remodelling by two‐photon microscopy after micro‐ablative fractional laser resurfacing , 2014, Journal of biophotonics.

[5]  Atsushi Yoshiki,et al.  High Resolution Intravital Imaging of Subcellular Structures of Mouse Abdominal Organs Using a Microstage Device , 2012, PloS one.

[6]  David D Sampson,et al.  Respiratory gating of anatomical optical coherence tomography images of the human airway. , 2009, Optics express.

[7]  Iris Riemann,et al.  High-resolution multiphoton tomography of human skin with subcellular spatial resolution and picosecond time resolution. , 2003, Journal of biomedical optics.

[8]  Ralph Weissleder,et al.  Motion compensation using a suctioning stabilizer for intravital microscopy , 2012, Intravital.

[9]  B R Masters,et al.  Multiphoton excitation fluorescence microscopy and spectroscopy of in vivo human skin. , 1997, Biophysical journal.

[10]  P. De Koninck,et al.  Adaptive Movement Compensation for In Vivo Imaging of Fast Cellular Dynamics within a Moving Tissue , 2011, PloS one.

[11]  Jin Ung Kang,et al.  Motion compensated fiber-optic confocal microscope based on a common-path optical coherence tomography distance sensor , 2011 .

[12]  R. Weissleder,et al.  Real-time in vivo imaging of the beating mouse heart at microscopic resolution , 2012, Nature Communications.

[13]  Jin U. Kang,et al.  Motion-compensated hand-held common-path Fourier-domain optical coherence tomography probe for image-guided intervention , 2012, Photonics West - Biomedical Optics.