Combining ensemble empirical mode decomposition with spectrum subtraction technique for heart rate monitoring using wrist-type photoplethysmography

Abstract Photoplethysmography (PPG)-based heart rate (HR) monitoring is a promising feature in modern wearable devices. However, it is difficult to accurately track HR during physical exercise since PPG signals are vulnerable to motion artifacts (MA). In this paper, an algorithm is presented to combine ensemble empirical mode decomposition (EEMD) with spectrum subtraction (SS) to track HR changes during subjects’ physical activities. In this algorithm, EEMD decomposes a PPG signal and an acceleration signal into intrinsic mode functions (IMFs), respectively. Then noise related IMFs are removed. Next the correlation coefficient is computed between the spectrum of the acceleration signal and that of the PPG signal in the band of [0.4 Hz–5 Hz]. If the coefficient is above 0.5, SS is used to remove the spectrum of the acceleration signal from the PPG's spectrum. Finally, a spectral peak selection method is used to find the peak corresponding to HR. Experimental results on datasets recorded from 12 subjects during fast running showed the superior performance of the proposed algorithm compared with a benchmark method termed TROIKA. The average absolute error of HR estimation was 1.83 beats per minute (BPM), and the Pearson correlation was 0.989 between the ground-truth and the estimated HR.

[1]  Bhaskar D. Rao,et al.  Sparse solutions to linear inverse problems with multiple measurement vectors , 2005, IEEE Transactions on Signal Processing.

[2]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[3]  Boreom Lee,et al.  Improved elimination of motion artifacts from a photoplethysmographic signal using a Kalman smoother with simultaneous accelerometry , 2010, Physiological measurement.

[4]  Walter Karlen,et al.  Empirical mode decomposition for respiratory and heart rate estimation from the photoplethysmogram , 2013, Computing in Cardiology 2013.

[5]  Yung-Hung Wang,et al.  On the computational complexity of the empirical mode decomposition algorithm , 2014 .

[6]  Haruki Kawanaka,et al.  Estimating heart rate using wrist-type Photoplethysmography and acceleration sensor while running , 2012, 2012 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[7]  J. Vagedes,et al.  How accurate is pulse rate variability as an estimate of heart rate variability? A review on studies comparing photoplethysmographic technology with an electrocardiogram. , 2013, International journal of cardiology.

[8]  N. Huang,et al.  The empirical mode decomposition and the Hilbert spectrum for nonlinear and non-stationary time series analysis , 1998, Proceedings of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences.

[9]  John Allen Photoplethysmography and its application in clinical physiological measurement , 2007, Physiological measurement.

[10]  Sun K. Yoo,et al.  Motion artifact reduction in photoplethysmography using independent component analysis , 2006, IEEE Transactions on Biomedical Engineering.

[11]  Steve Warren,et al.  Two-Stage Approach for Detection and Reduction of Motion Artifacts in Photoplethysmographic Data , 2010, IEEE Transactions on Biomedical Engineering.

[12]  Ping Yang,et al.  Artifact reduction based on Empirical Mode Decomposition (EMD) in photoplethysmography for pulse rate detection , 2010, 2010 Annual International Conference of the IEEE Engineering in Medicine and Biology.

[13]  Mehrdad Nourani,et al.  A Motion-Tolerant Adaptive Algorithm for Wearable Photoplethysmographic Biosensors , 2014, IEEE Journal of Biomedical and Health Informatics.

[14]  Ki H. Chon,et al.  Automatic Motion and Noise Artifact Detection in Holter ECG Data Using Empirical Mode Decomposition and Statistical Approaches , 2012, IEEE Transactions on Biomedical Engineering.

[15]  Zhilin Zhang,et al.  TROIKA: A General Framework for Heart Rate Monitoring Using Wrist-Type Photoplethysmographic Signals During Intensive Physical Exercise , 2014, IEEE Transactions on Biomedical Engineering.

[16]  Abdel-Ouahab Boudraa,et al.  EMD-Based Filtering Using Similarity Measure Between Probability Density Functions of IMFs , 2014, IEEE Transactions on Instrumentation and Measurement.

[17]  Weidong Wang,et al.  Motion artifact removal from photoplethysmographic signals by combining temporally constrained independent component analysis and adaptive filter , 2014, Biomedical engineering online.

[18]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.

[19]  Reinhold Orglmeister,et al.  Improved signal quality indication for photoplethysmographic signals incorporating motion artifact detection , 2014, 2014 36th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[20]  Norden E. Huang,et al.  Ensemble Empirical Mode Decomposition: a Noise-Assisted Data Analysis Method , 2009, Adv. Data Sci. Adapt. Anal..

[21]  E. Hari Krishna,et al.  A Novel Approach for Motion Artifact Reduction in PPG Signals Based on AS-LMS Adaptive Filter , 2012, IEEE Transactions on Instrumentation and Measurement.