Micrometer-scale resolution imaging of the anterior eye in vivo with optical coherence tomography.

OBJECTIVE To demonstrate a new diagnostic technique, optical coherence tomography, for high-resolution cross-sectional imaging of structures in the anterior segment of the human eye in vivo. Optical coherence tomography is a new, noninvasive, noncontact optical imaging modality that has spatial resolution superior to that of conventional clinical ultrasonography (< 20 microns) and high sensitivity (dynamic range, > 90 dB). DESIGN Survey of intraocular structure and dimension measurements. SETTING Laboratory. PATIENTS Convenience sample. MAIN OUTCOME MEASURES Correlation with range of accepted normal intraocular structure profiles and dimensions. RESULTS Direct in vivo measurements with micrometer-scale resolution were performed of corneal thickness and surface profile (including visualization of the corneal epithelium), anterior chamber depth and angle, and iris thickness and surface profile. Dense nuclear cataracts were successfully imaged through their full thickness in a cold cataract model in calf eyes in vitro. CONCLUSIONS Optical coherence tomography has potential as a diagnostic tool for applications in noncontact biometry, anterior chamber angle assessment, identification and monitoring of intraocular masses and tumors, and elucidation of abnormalities of the cornea, iris, and crystalline lens.

[1]  D. Davies,et al.  Optical coherence-domain reflectometry: a new optical evaluation technique. , 1987, Optics letters.

[2]  Richard S. Snell,et al.  Clinical Anatomy of the Eye , 1990 .

[3]  Robert H. Webb,et al.  Scanning Laser Ophthalmoscope , 1981, IEEE Transactions on Biomedical Engineering.

[4]  F. Foster,et al.  Clinical use of ultrasound biomicroscopy. , 1991, Ophthalmology.

[5]  J. Kammann,et al.  Comparison of contact and immersion techniques for axial length measurement and implant power calculation , 1989, Journal of cataract and refractive surgery.

[6]  J. Fujimoto,et al.  In vivo retinal imaging by optical coherence tomography. , 1993, Optics letters.

[7]  B R Frueh,et al.  Corneal thickness measured by interferometry. , 1975, Journal of the Optical Society of America.

[8]  J. Schmitt,et al.  Measurement of optical properties of biological tissues by low-coherence reflectometry. , 1993, Applied optics.

[9]  H. Dwight Cavanagh,et al.  Confocal Microscopic Imaging of the Living Eye with Tandem Scanning Confocal Microscopy , 1990 .

[10]  Gordon S. Kino,et al.  Confocal Microscopy Of The Eye. , 1989, Optics & Photonics.

[11]  P. G. Story,et al.  Axial length and the average ophthalmologist--is biometry worthwhile? , 1989, Ophthalmic surgery.

[12]  J. Fujimoto,et al.  High-speed optical coherence domain reflectometry. , 1992, Optics letters.

[13]  J G Fujimoto,et al.  Femtosecond optical ranging of corneal incision depth. , 1989, Investigative ophthalmology & visual science.

[14]  Theo Seiler,et al.  Magnetic Resonance Imaging of the Eye and Orbit , 1990 .

[15]  C K Hitzenberger,et al.  Optical measurement of the axial eye length by laser Doppler interferometry. , 1991, Investigative ophthalmology & visual science.

[16]  J. Fujimoto,et al.  Femtosecond optical ranging in biological systems. , 1986, Optics letters.

[17]  Josef F. Bille,et al.  Scanning Laser Tomography of the Living Human Eye , 1990 .

[18]  J. Fujimoto,et al.  Optical coherence microscopy in scattering media. , 1994, Optics letters.

[19]  K. Takada,et al.  New measurement system for fault location in optical waveguide devices based on an interferometric technique. , 1987, Applied optics.

[20]  J. Fujimoto,et al.  Micron‐resolution ranging of cornea anterior chamber by optical reflectometry , 1991, Lasers in surgery and medicine.

[21]  Joseph A. Izatt,et al.  Ophthalmic diagnostics using optical coherence tomography , 1993, Photonics West - Lasers and Applications in Science and Engineering.

[22]  C K Hitzenberger,et al.  Mêasurement of corneal thickness by low-coherence interferometry. , 1992, Applied optics.

[23]  D. Azar,et al.  High-frequency ultrasound quantitative analyses of corneal scarring following excimer laser keratectomy. , 1993, Archives of ophthalmology.

[24]  F. Foster,et al.  Subsurface ultrasound microscopic imaging of the intact eye. , 1990, Ophthalmology.

[25]  J. L. Taveras,et al.  Magnetic Resonance Imaging Ophthalmology , 1990 .