An analysis of daylighting performance for office buildings in Hong Kong

Daylighting has often been recognized as a useful source of energy savings and visual comforts in buildings. Occupants expect good daylight in their working spaces. The quality and quantity of natural light entering a building depend on both internal and external factors. In Hong Kong, commercial building accounts for the major building energy use and electric lighting is one of the major electricity-consuming items. This paper studies the daylighting performance and energy implications for office buildings. A total of 35 commercial buildings have been selected in the survey. Key building parameters affecting daylighting designs are presented. Two typical office blocks were further analysed based on a lighting simulation program. The daylighting performance was evaluated in terms of daylight factor, room depth and glare index. It has been found that the daylighting performance for office buildings is quite effective. About one-third of the office areas that are near the perimeter regions have an average daylight factor of 5%. For inner region of deep plan offices, some innovative daylighting systems such as light redirecting panels and light pipe could be used to improve the daylighting performance. In general, the office building envelop designs are conducive to effective daylighting and proper daylight linked lighting controls could save over 25% of the total electric lighting use.

[1]  Sai On Cheung,et al.  An analysis of electricity end-use in air-conditioned office buildings in Hong Kong , 2003 .

[2]  J. A. Lynes,et al.  A sequence for daylighting design , 1979 .

[3]  D. Li,et al.  An analysis of measured and simulated daylight illuminance and lighting savings in a daylit corridor , 2005 .

[4]  Ian Edmonds Daylighting high-density residential buildings with light redirecting panels , 2005 .

[5]  Joseph C. Lam,et al.  Vertical solar radiation and daylight illuminance data for Hong Kong , 2000 .

[6]  Danny H.W. Li,et al.  Evaluation of lighting performance in office buildings with daylighting controls , 2001 .

[7]  Jean-Louis Scartezzini,et al.  Design and assessment of an anidolic light-duct , 1998 .

[8]  G. W. Larson,et al.  Rendering with radiance - the art and science of lighting visualization , 2004, Morgan Kaufmann series in computer graphics and geometric modeling.

[9]  Christoph F. Reinhart,et al.  The simulation of annual daylight illuminance distributions — a state-of-the-art comparison of six RADIANCE-based methods , 2000 .

[10]  Dj Carter Developments in tubular daylight guidance systems , 2004 .

[11]  Alfonso Soler,et al.  Light shelf performance in Madrid, Spain , 1997 .

[12]  J. C. Lam,et al.  Measurements of solar radiation and illuminance on vertical surfaces and daylighting implications , 2000 .

[13]  Danny H.W. Li,et al.  Daylighting and its implications to overall thermal transfer value (OTTV) determinations , 2002 .

[14]  Veronica Garcia Hansen,et al.  The use of light pipes for deep plan office buildings: A case study of Ken Yeang's bioclimatic skyscraper prposal for KLCC, Malaysia , 2001 .

[15]  Aris Tsangrassoulis,et al.  Numerical estimation of street canyon albedo consisting of vertical coated glazed facades , 2003 .

[16]  Moncef Krarti,et al.  A simplified method to estimate energy savings of artificial lighting use from daylighting , 2005 .

[17]  P. Tregenza Mean daylight illuminance in rooms facing sunlit streets , 1995 .

[18]  Danny H.W. Li,et al.  An investigation of daylighting performance and energy saving in a daylit corridor , 2003 .

[19]  Fabio Peron,et al.  Daylight and energy performances of a new type of light pipe , 2004 .

[20]  L. Roche,et al.  Occupant reactions to daylight in offices , 2000 .

[21]  R. Dogniaux,et al.  Glare from windows: current views of the problem , 1982 .