A Novel Method for Screening the PMU Phase Angle Difference Data Based on Hyperplane Clustering

Compared with the traditional supervisory control and data acquisition (SCADA) data, phasor measurement unit (PMU) data is characterized by phase angle measurement and high reporting speed (perhaps 100 Hz). The high reporting speed provides dynamic characteristics of the power system frequency, voltage, and current measurement. PMUs have become one of the important data sources for smart grid monitoring. PMU/WAMS (wide area measurement system) based advanced applications have been widely used in the dispatch centers. Some of the applications, such as line parameter identification and state estimation, depend not only on phase angle data but also on phase angle difference between different locations. Field data can suffer from errors, such as time synchronization error, transducer error, PMU algorithm error, hardware error or malicious attacks, etc. A time synchronization error can directly cause an error in the phase angle difference calculated between the two ends of a transmission line that could degrade a PMU based application. In this paper, a novel method to cluster the phase angle difference data, assess the data quality and screen out the bad PMU phase angle difference data is proposed. First, we develop the hyperplane cluster method to cluster the phase angle difference data. Second, in order to screen out the right data type, this paper compares the virtual reactance parameters of each data type obtained by voltage mean to the line reactance parameter given by the system model. Finally, the performance of the proposed methods has been verified by a simulation. The efficiency of the proposed method has been analyzed. The application of the proposed method using field measured PMU data shows the engineering practicability of the proposed method. In addition, the comparison of the proposed method with other clustering methods is discussed.

[1]  Anurag K. Srivastava,et al.  Ensemble-Based Algorithm for Synchrophasor Data Anomaly Detection , 2019, IEEE Transactions on Smart Grid.

[2]  Zhang Dongyin Reconstruction Method of Active Power Historical Operating Data for Wind Farm , 2014 .

[3]  Di Shi,et al.  Calculating sequence impedances of transmission line using PMU measurements , 2015, 2015 IEEE Power & Energy Society General Meeting.

[4]  Qing Zhang,et al.  The Integrated Calibration of Synchronized Phasor Measurement Data in Power Transmission Systems , 2011, IEEE Transactions on Power Delivery.

[5]  Liang Du,et al.  Synchrophasor Data Correction Under GPS Spoofing Attack: A State Estimation-Based Approach , 2018, IEEE Transactions on Smart Grid.

[6]  Xiaochuan Luo,et al.  PMU data validation at ISO New England , 2013, 2013 IEEE Power & Energy Society General Meeting.

[7]  Di Shi,et al.  An adaptive method for detection and correction of errors in PMU measurements , 2013, 2013 IEEE Power & Energy Society General Meeting.

[8]  Geoffrey Blewitt,et al.  The Effect of Weather Fronts on GPS Measurements , 1998 .

[9]  Fan Qi Synchronous phasor measurement unit and error analysis , 2004 .

[10]  Yilu Liu,et al.  Impact of GPS signal loss and its mitigation in power system synchronized measurement devices , 2017 .

[11]  Zhiwei Wang,et al.  Online Identification and Data Recovery for PMU Data Manipulation Attack , 2019, IEEE Transactions on Smart Grid.

[12]  Arun G. Phadke,et al.  Synchronized Phasor Measurements and Their Applications , 2008 .

[13]  Tianshu Bi,et al.  Impact of transient response of instrument transformers on phasor measurements , 2010, IEEE PES General Meeting.

[14]  Vladimir Terzija,et al.  A Method for Accurate Parameter Estimation of Series Compensated Transmission Lines Using Synchronized Data , 2017, IEEE Transactions on Power Systems.

[15]  Deepa Kundur,et al.  Cyber attack detection in PMU measurements via the expectation-maximization algorithm , 2014, 2014 IEEE Global Conference on Signal and Information Processing (GlobalSIP).

[16]  L Vanfretti,et al.  A Phasor-Data-Based State Estimator Incorporating Phase Bias Correction , 2011, IEEE Transactions on Power Systems.

[17]  Hongbin Sun,et al.  Advancing China?s Smart Grid: Phasor Measurement Units in a Wide-Area Management System , 2015, IEEE Power and Energy Magazine.

[18]  Qi Wenbi The Difference Between SCADA and WAMS Real-Time Data in Dispatching Center , 2013 .

[19]  Husheng Li,et al.  GPS spoofing based time stamp attack on real time wide area monitoring in smart grid , 2012, 2012 IEEE Third International Conference on Smart Grid Communications (SmartGridComm).

[20]  Husheng Li,et al.  Time Synchronization Attack in Smart Grid: Impact and Analysis , 2013, IEEE Transactions on Smart Grid.

[21]  Huang Yuanchao Research and Development of New Wide Area Out-of-Step Control Technology for Power Systems , 2013 .

[22]  Chong Wang,et al.  Multi-Area Dynamic State Estimation With PMU Measurements by an Equality Constrained Extended Kalman Filter , 2018, IEEE Transactions on Smart Grid.

[23]  R. Baldick,et al.  Implementing nonquadratic objective functions for state estimation and bad data rejection , 1997 .

[24]  Di Shi,et al.  Online Calibration of Phasor Measurement Unit Using Density-Based Spatial Clustering , 2017, IEEE Transactions on Power Delivery.

[25]  Lei Wang,et al.  Impact of GPS signal quality on the performance of phasor measurements , 2011, 2011 16th International Conference on Intelligent System Applications to Power Systems.

[26]  James S. Thorp,et al.  Synchronized Phasor Measurement Applications in Power Systems , 2010, IEEE Transactions on Smart Grid.

[27]  Xu Zhi-gao Regression Forecast and Abnormal Data Detection Based on Support Vector Regression , 2009 .

[28]  Vladimir Terzija,et al.  A Method for Accurate Parameter Estimation of Series Compensated Transmission Lines Using Synchronized Data , 2018, 2018 IEEE Power & Energy Society General Meeting (PESGM).

[29]  Joe H. Chow,et al.  Classification and Detection of PMU Data Manipulation Attacks Using Transmission Line Parameters , 2018, IEEE Transactions on Smart Grid.