Effect of the initial gas maldistribution on the pressure drop of structured packings

Abstract This paper presents results of a large-scale experimental study devoted to establishing the relation between the quality of initial gas (mal)distribution, as created by common liquid collecting devices used in redistribution sections of packed columns, and the hydraulics of a structured packing bed. Both dry and wet bed experiments were conducted with air–water system under ambient conditions, using a 1.4 m i.d. Plexiglas column, including also high liquid loads. Additional, controlled gas maldistribution studies were conducted to observe the bed height needed to smooth out various types of initial maldistribution. From dry and wet experiments, it appeared that the type (severity) of initial gas maldistribution influences the pressure drop of the bed.

[1]  J. F. Billingham,et al.  Characterization of the performance of packed distillation column liquid distributors , 1997 .

[2]  F. Zuiderweg,et al.  A model for the calculation of the effect of maldistribution on the efficiency of a packed column , 1993 .

[3]  D. DarakchievRumen,et al.  Gas flow distribution in packed columns , 2002 .

[4]  M. Lockett,et al.  A simple method to assess the sensitivity of packed distillation columns to maldistribution , 2002 .

[5]  Ž. Olujić,et al.  Modelling and measurement of gas flow distribution in corrugated sheet structured packings , 1993 .

[6]  Z. Olujic,et al.  EXPERIMENTAL CHARACTERISATION AND CFD SIMULATION OF GAS DISTRIBUTION PERFORMANCE OF LIQUID ( RE ) DISTRIBUTORS AND COLLECTORS IN PACKED COLUMNS , 2002 .

[7]  Z. Olujic,et al.  Gas distribution in large-diameter packed columns , 1991 .

[8]  R. M. Stikkelman,et al.  A study of gas and liquid distributions in structured packings , 1989 .

[9]  C. Briens,et al.  Low pressure drop gas distributors for packed distillation columns , 1986 .

[10]  Z. Olujic,et al.  Experimental Studies on the Interaction Between the Initial Liquid Distribution and the Performance of Structured Packings , 1990 .

[11]  I. M. Parsons Gas distribution in shallow packed beds , 1991 .

[12]  D. Edwards,et al.  Development of an improved method to quantify maldistribution and its effect on structured packing column performance , 1999 .

[13]  J. G. Kunesh,et al.  Controlled Liquid Maldistribution Studies on Structured Packing , 1999 .