Biofix fixation techniques and results in foot surgery.

Biofix absorbable rods have been used for internal fixation for 10 years, and one of its most utilized applications has been osteotomies of the first metatarsal. This study evaluates 59 procedures on 49 patients completed over a 3-year period, using the 2.0-mm. Biofix rods. The transarticular technique for the fixation of osteotomies in the 1st and 5th metatarsals and the intramedullary technique used for digital fusions are described. All of the patients were followed for a minimum of 3 months, but most for > 1 year, and all of the procedures were evaluated for failure of fixation, osteolytic bone changes, sterile sinus development, and infection. There were no failures of fixation and no infections in this series. Patients (22.4%) developed radiographic osteolytic changes, and 4.1% of the patients developed sterile sinus discharge. However, these had no effect on the procedures' success or outcomes. An introduction to future application of the technology using Biofix screws and plates is made with a pantalar fusion case as an example.

[1]  O. Böstman,et al.  Biodegradable fixation of distal humeral physeal fractures. , 1992, Clinical orthopaedics and related research.

[2]  E. Mäkelä,et al.  THE EFFECT OF TRAUMA TO THE LOWER FEMORAL EPIPHYSEAL PLATE , 1988, The Journal of bone and joint surgery. British volume.

[3]  O. Böstman,et al.  Chevron Osteotomy Fixed with Absorbable Polyglycolide Pins , 1991, Foot & ankle.

[4]  R. Parks,et al.  Complications with the use of bioabsorbable pins in the foot. , 1993, The Journal of foot and ankle surgery : official publication of the American College of Foot and Ankle Surgeons.

[5]  M. Henley,et al.  Fixation with bioabsorbable screws for the treatment of fractures of the ankle. , 1994, The Journal of bone and joint surgery. American volume.

[6]  P. Törmälä,et al.  Fixation of experimental osteotomies of the distal femur of rabbits with biodegradable material , 2004, Archives of orthopaedic and traumatic surgery.

[7]  E. Hirvensalo Fracture fixation with biodegradable rods. Forty-one cases of severe ankle fractures. , 1989, Acta orthopaedica Scandinavica.

[8]  O. Böstman,et al.  Ankle fractures treated using biodegradable internal fixation. , 1989, Clinical orthopaedics and related research.

[9]  O. Böstman,et al.  Degradable polyglycolide rods for the internal fixation of displaced bimalleolar fractures , 2004, International Orthopaedics.

[10]  O. Böstman,et al.  Impact of the use of absorbable fracture fixation implants on consumption of hospital resources and economic costs. , 1991, The Journal of trauma.

[11]  O. Böstman,et al.  Absorbable pins of self-reinforced poly-L-lactic acid for fixation of fractures and osteotomies. , 1992, The Journal of bone and joint surgery. British volume.

[12]  P. Törmälä,et al.  The Effect of a Penetrating Biodegradable Implant on the Epiphyseal Plate: An Experimental Study on Growing Rabbits with Special Regard to Polyglactin 910 , 1987, Journal of pediatric orthopedics.

[13]  O. Böstman,et al.  Osteolytic changes accompanying degradation of absorbable fracture fixation implants. , 1991, The Journal of bone and joint surgery. British volume.

[14]  W. Cole,et al.  Osteolysis after biodegradable pin fixation of fractures in children. , 1992, The Journal of bone and joint surgery. British volume.

[15]  O. Böstman,et al.  Absorbable polyglycolide pins in fixation of displaced fractures of the radial head , 2004, Archives of Orthopaedic and Trauma Surgery.

[16]  O. Böstman,et al.  Foreign-body reactions to polyglycolide screws. Observations in 24/216 malleolar fracture cases. , 1992, Acta orthopaedica Scandinavica.

[17]  O. Böstman,et al.  Foreign-body reactions to fracture fixation implants of biodegradable synthetic polymers. , 1990, The Journal of bone and joint surgery. British volume.

[18]  J. Gerbert Effectiveness of absorbable fixation devices in Austin bunionectomies. , 1992, Journal of the American Podiatric Medical Association.

[19]  W. Cole,et al.  Biodegradable pin fixation of elbow fractures in children. A randomised trial. , 1992, The Journal of bone and joint surgery. British volume.