Monoterpene separation by coupling proton transfer reaction time-of-flight mass spectrometry with fastGC

Proton transfer reaction mass spectrometry (PTR-MS) is a well-established technique for real-time analysis of volatile organic compounds (VOCs). Although it is extremely sensitive (with sensitivities of up to 4500 cps/ppbv, limits of detection <1 pptv and the response times of approximately 100 ms), the selectivity of PTR-MS is still somewhat limited, as isomers cannot be separated. Recently, selectivity-enhancing measures, such as manipulation of drift tube parameters (reduced electric field strength) and using primary ions other than H3O+, such as NO+ and O2+, have been introduced. However, monoterpenes, which belong to the most important plant VOCs, still cannot be distinguished so more traditional technologies, such as gas chromatography mass spectrometry (GC-MS), have to be utilised. GC-MS is very time consuming (up to 1 h) and cannot be used for real-time analysis. Here, we introduce a sensitive, near-to-real-time method for plant monoterpene research—PTR-MS coupled with fastGC. We successfully separated and identified six of the most abundant monoterpenes in plant studies (α- and β-pinenes, limonene, 3-carene, camphene and myrcene) in less than 80 s, using both standards and conifer branch enclosures (Norway spruce, Scots pine and black pine). Five monoterpenes usually present in Norway spruce samples with a high abundance were separated even when the compound concentrations were diluted to 20 ppbv. Thus, fastGC-PTR-ToF-MS was shown to be an adequate one-instrument solution for plant monoterpene research.

[1]  Werner Lindinger,et al.  Proton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb level , 1995 .

[2]  O. S. L. S. Ms,et al.  Factors Influencing Practice Area Preference in Occupational Therapy , 1999 .

[3]  Mathijs F. G. Lucassen,et al.  Impact of a Workshop on Motivation to Pursue a Career in Child and Adolescent Mental Health , 2007, The Australian and New Zealand journal of psychiatry.

[4]  H. Kjaergaard,et al.  A large source of low-volatility secondary organic aerosol , 2014, Nature.

[5]  H. Hakola,et al.  Chemodiversity of a Scots pine stand and implications for terpene air concentrations , 2012 .

[6]  M. Heal,et al.  Development of PTR-MS selectivity for structural isomers: monoterpenes as a case study , 2012 .

[7]  Tianshu Wang,et al.  Selected ion flow tube, SIFT, studies of the reactions of H3O+, NO+ and O2+ with eleven C10H16 monoterpenes , 2003 .

[8]  Jean Underwood,et al.  Research into information and communications technologies: where now? , 2004 .

[9]  A. Hansel,et al.  On-line monitoring of volatile organic compounds at pptv levels by means of proton-transfer-reaction mass spectrometry (PTR-MS) medical applications, food control and environmental research , 1998 .

[10]  Philip Race,et al.  The Open Learning Handbook: Promoting Quality in Designing and Delivering Flexible Learning , 1989 .

[11]  Philipp Sulzer,et al.  An online ultra-high sensitivity Proton-transfer-reaction mass-spectrometer combined with switchable reagent ion capability (PTR + SRI − MS) , 2009 .

[12]  C. Mayhew,et al.  Proton Transfer Reaction Mass Spectrometry: Principles and Applications , 2014 .

[13]  B N Colby,et al.  Spectral deconvolution for overlapping GC/MS components , 1992, Journal of the American Society for Mass Spectrometry.

[14]  Edward B. Overton,et al.  Fast GC instrumentation and analysis for field applications , 2001 .

[15]  S. Kellomäki,et al.  Monoterpene emission of a boreal Scots pine (Pinus sylvestris L.) forest , 2009 .

[16]  R. Janson Monoterpene emissions from Scots pine and Norwegian spruce , 1993 .

[17]  P. Hari,et al.  On-line field measurements of monoterpene emissions from Scots pine by proton-transfer-reaction mass spectrometry , 2005 .

[18]  Jen Harvey,et al.  Using a toolkit to support the evaluation of learning , 2002, J. Comput. Assist. Learn..

[19]  P Washer,et al.  Barriers to the use of web-based learning in nurse education. , 2001, Nurse education today.

[20]  D. Armbruster,et al.  Limit of blank, limit of detection and limit of quantitation. , 2008, The Clinical biochemist. Reviews.

[21]  T. Märk,et al.  A Proton Transfer Reaction-Quadrupole interface Time-Of-Flight Mass Spectrometer (PTR-QiTOF): High speed due to extreme sensitivity , 2014 .

[22]  Thomas C. Reeves,et al.  Design research: A socially responsible approach to instructional technology research in higher education , 2005, J. Comput. High. Educ..

[23]  C. N. Hewitt,et al.  Measurement of monoterpenes and related compounds by proton transfer reaction-mass spectrometry (PTR-MS) , 2003 .

[24]  Otr Faota M. Jeanne Madigan EdD,et al.  Academic Factors and Changes in Practice Area Preference , 1999 .

[25]  T. Märk,et al.  Unambiguous identification of volatile organic compounds by proton-transfer reaction mass spectrometry coupled with GC/MS. , 2005, Analytical Chemistry.

[26]  T. Märk,et al.  Distinguishing two isomeric mephedrone substitutes with selective reagent ionisation mass spectrometry (SRI-MS). , 2013, Journal of mass spectrometry : JMS.

[27]  Franco Biasioli,et al.  Wine analysis by FastGC proton-transfer reaction-time-of-flight-mass spectrometry , 2014 .

[28]  K. Gough,et al.  We can't find the Solution until We Know the Problem: Understanding the Mental Health Nursing Labour Force , 2007, Australasian psychiatry : bulletin of Royal Australian and New Zealand College of Psychiatrists.

[29]  P. Wittman,et al.  Variables affecting specialty choice in occupational therapy. , 1989, The American journal of occupational therapy : official publication of the American Occupational Therapy Association.

[30]  Thomas C. Reeves,et al.  Patterns of engagement in authentic online learning environments , 2003, ASCILITE.

[31]  V. Braun,et al.  Using thematic analysis in psychology , 2006 .

[32]  Georg Wohlfahrt,et al.  Detection of Plant Volatiles after Leaf Wounding and Darkening by Proton Transfer Reaction “Time-of-Flight” Mass Spectrometry (PTR-TOF) , 2011, PloS one.

[33]  P. Monks,et al.  Proton-transfer reaction mass spectrometry. , 2009, Chemical reviews.

[34]  Brett A. Seabury,et al.  Using Computers to Teach Practice Skills , 1993 .

[35]  B. Christie,et al.  Fieldwork experience, Part I: Impact on practice preference. , 1985, The American journal of occupational therapy : official publication of the American Occupational Therapy Association.

[36]  R. Fall,et al.  Volatile organic compounds emitted after leaf wounding: On‐line analysis by proton‐transfer‐reaction mass spectrometry , 1999 .

[37]  D. Cotton,et al.  The rhetoric and reality of e‐learning: using the think‐aloud method to evaluate an online resource , 2007 .

[38]  David Smith,et al.  Selected ion flow tube mass spectrometry (SIFT-MS) for on-line trace gas analysis. , 2005, Mass spectrometry reviews.

[39]  Iain Doherty,et al.  An Instructional Design Course for Clinical Educators: First Iteration Design Research Reflections , 2007 .