Segmentation of corneal optical coherence tomography images using randomized Hough transform

Measuring the thickness of different corneal microlayers is important for the diagnosis of common corneal eye diseases such as dry eye, keratoconus, Fuchs endothelial dystrophy, and corneal graft rejection. High resolution corneal images, obtained using optical coherence tomography (OCT), made it possible to measure the thickness of different corneal microlayers in vivo. The manual segmentation of these images is subjective and time consuming. Therefore, automatic segmentation is necessary. Several methods were proposed for segmenting corneal OCT images, but none of these methods segment all the microlayer interfaces and they are not robust. In addition, the lack of a large annotated database of corneal OCT images impedes the application of machine learning methods such as deep learning which proves to be very powerful. In this paper, we present a new corneal OCT image segmentation algorithm using Randomized Hough Transform. To the best of our knowledge, we developed the first automatic segmentation method for the six corneal microlayer interfaces. The proposed method includes a robust estimate of relative distances of inner corneal interfaces with respect to outer corneal interfaces. Also, it handles properly the correct ordering and the non-intersection of corneal microlayer interfaces. The proposed method was tested on 15 corneal OCT images that were randomly selected. OCT images were manually segmented by two trained operators for comparison. Comparison with the manual segmentation shows that the proposed method has mean segmentation error of 3.77±4.25 pixels across all interfaces which corresponds to 5.66 ± 6.38μm. The mean segmentation error between the two manual operators is 4.07 ± 4.71 pixels, which corresponds to 6.11 ± 7.07μm. The proposed method takes a mean time of 2.59 ± 0.06 seconds to segment six corneal interfaces.

[1]  Joseph A. Izatt,et al.  Real-time corneal segmentation and 3D needle tracking in intrasurgical OCT , 2018, Biomedical optics express.

[2]  Sander R. Dubovy,et al.  Descemet Membrane Thickening as a Sign for the Diagnosis of Corneal Graft Rejection: An Ex Vivo Study , 2017, Cornea.

[3]  Guanglin Li,et al.  A Novel Technique for Robust and Fast Segmentation of Corneal Layer Interfaces Based on Spectral-Domain Optical Coherence Tomography Imaging , 2017, IEEE Access.

[4]  William J Feuer,et al.  In Vivo Characteristics of Corneal Endothelium/Descemet Membrane Complex for the Diagnosis of Corneal Graft Rejection. , 2017, American journal of ophthalmology.

[5]  Yalin Zheng,et al.  Reconstruction of 3D surface maps from anterior segment optical coherence tomography images using graph theory and genetic algorithms , 2016, Biomed. Signal Process. Control..

[6]  Yalin Zheng,et al.  Fast segmentation of anterior segment optical coherence tomography images using graph cut , 2015, Eye and Vision.

[7]  Hossein Rabbani,et al.  An Automatic Algorithm for Segmentation of the Boundaries of Corneal Layers in Optical Coherence Tomography Images using Gaussian Mixture Model , 2014, Journal of medical signals and sensors.

[8]  William J Feuer,et al.  The use of Bowman's layer vertical topographic thickness map in the diagnosis of keratoconus. , 2014, Ophthalmology.

[9]  Yalin Zheng,et al.  Automatic segmentation of anterior segment optical coherence tomography images , 2013, Journal of biomedical optics.

[10]  Yankui Sun,et al.  AUTOMATED EXTRACTION OF THE INNER CONTOUR OF THE ANTERIOR CHAMBER USING OPTICAL COHERENCE TOMOGRAPHY IMAGES , 2012 .

[11]  Joseph A. Izatt,et al.  Robust automatic segmentation of corneal layer boundaries in SDOCT images using graph theory and dynamic programming , 2011, Biomedical optics express.

[12]  David A. Clausi,et al.  Automated 3D Reconstruction and Segmentation from Optical Coherence Tomography , 2010, ECCV.

[13]  Shuliang Jiao,et al.  Use of ultra-high-resolution optical coherence tomography to detect in vivo characteristics of Descemet's membrane in Fuchs' dystrophy. , 2010, Ophthalmology.

[14]  David A. Clausi,et al.  A Novel Algorithm for Extraction of the Layers of the Cornea , 2009, 2009 Canadian Conference on Computer and Robot Vision.

[15]  Yan Li,et al.  Segmentation of 830- and 1310-nm LASIK corneal optical coherence tomography images , 2002, SPIE Medical Imaging.

[16]  Erkki Oja,et al.  Randomized Hough transform (RHT) , 1990, [1990] Proceedings. 10th International Conference on Pattern Recognition.

[17]  Josef Kittler,et al.  A survey of the hough transform , 1988, Comput. Vis. Graph. Image Process..

[18]  Robert C. Bolles,et al.  Random sample consensus: a paradigm for model fitting with applications to image analysis and automated cartography , 1981, CACM.

[19]  Xiaodong Wu,et al.  Optimal Surface Segmentation in Volumetric Images-A Graph-Theoretic Approach , 2006, IEEE Transactions on Pattern Analysis and Machine Intelligence.

[20]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.