Microbiological quality of packaged drinking water brands marketed in Ibadan metropolis and Ile-Ife city in South Western Nigeria

Continuous increase in the sale and indiscriminate consumption of packaged drinking waters in Nigeria is of public health significance. One hundred and eight samples comprising 16 bottled and 20 sachet water brands purchased randomly all over Ibadan and Ile-Ife cities in South Western Nigeria were analysed for presence of bacterial indicators of water quality. Total heterotrophic bacteria plate counts (HPC) ranged from 2 to 150 for bottled water and 5 to 200 for sachet water brands. One brand of bottled water and eight brands of sachet water had mean HPC greater than 100 per ml millilitre water and thus fell below the United States Environmental Protection Agency (USEPA) and World Health Organisation (WHO) dinking water standard of 100 HPC per millilitre water. Total coliforms and Escherichia coli were detected in only one brand of bottled water. All brands of sachet water (100%) had total coliforms, four brands (20%) had presence of E. coli while Enterococcus faecalis was recovered from two (10%) of the brands. Most of the sachet water brands fell below WHO drinking water standards and are therefore of doubtful quality. Efforts need to be intensified in the monitoring of activities in this rapidly expanding industry with a view to raising standards.

[1]  M. Sridhar,et al.  Quality of packaged waters sold in ibadan, nigeria , 2010 .

[2]  D Warburton,et al.  A further review of the microbiological quality of bottled water sold in Canada: 1992-1997 survey results. , 1998, International journal of food microbiology.

[3]  John C. Clark,et al.  Contaminants In Drinking Water Estimating Costs , 1978 .

[4]  S. Gingras,et al.  Comparison of the microbiological quality of water coolers and that of municipal water systems , 1994, Applied and environmental microbiology.

[5]  Tracey Stickley DiPaola Biological and Chemical Renovation of Wastewater with a Soil Infiltrator Low-Pressure Distribution System , 1998 .

[6]  P. Payment,et al.  Poor efficacy of residual chlorine disinfectant in drinking water to inactivate waterborne pathogens in distribution systems. , 1999, Canadian journal of microbiology.

[7]  A. Olayemi,et al.  Microbial potability of bottled and packaged drinking waters hawked in Ilorin metropolis , 1999 .

[8]  A. Adesiyun,et al.  Microbial quality of domestic and imported brands of bottled water in Trinidad. , 2003, International journal of food microbiology.

[9]  M Exner,et al.  Heterotrophic plate count measurement in drinking water safety management: report of an Expert Meeting Geneva, 24-25 April 2002. , 2004, International journal of food microbiology.

[10]  K. Jones,et al.  The microbiological quality of drinking water sold on the streets in Kumasi, Ghana , 2003, Letters in applied microbiology.

[11]  W. Chao,et al.  Evaluation of Colilert-18 for Detection of Coliforms and Eschericha coli in Subtropical Freshwater , 2004, Applied and Environmental Microbiology.

[12]  M. Costa,et al.  Alterations in total bacteria, iodonitrophenyltetrazolium (INT)-positive bacteria, and heterotrophic plate counts of bottled mineral water , 1994 .