Geometrical and Stress Analysis of Factors Associated With Stent Fracture After Melody Percutaneous Pulmonary Valve Implantation

Background—Patients treated with the Melody device (Medtronic) for percutaneous pulmonary valve implantation experience stent fractures in ≈25% of the cases. The aim of this study is to identify the risk factors associated with fracture using 3-dimensional (3D) analyses. Methods and Results—In situ 3D shape of the Melody stent was reconstructed from 42 patients using procedural biplane fluoroscopy images, after balloon inflation, at systole and diastole. Four geometric parameters at systole and their variation during balloon deflation and cardiac cycles were measured to describe the 3D strut, cell, section, and stent configuration. Furthermore, patient-specific computer simulations were set up to replicate the history of stent deformations for each patient. Maximum and minimum principal stresses resulting from these analyses were monitored during balloon deflation and cardiac cycle. Univariate logistic regression analyses of 21 geometric parameters and of 4 stress parameters respectively, identified the decreased stent circularity after balloon deflation (odds ratio 0.98; 95% confidence interval, 0.96–0.99; P=0.006) and large compressive stresses during balloon deflation (odds ratio, 0.98; 0.96–0.997; P=0.03), as associated with the risk of fracture. In a multivariable logistic regression model, the 2 covariates identified on univariate analysis (1 geometric and 1 stress) were found to be independently associated with the risk of fracture. The resultant statistical model correctly identified fracture/no fracture in 93% of patients. Conclusions—Changes in stent section shape after balloon deflation are important variables influencing fracture. This methodology could help design tailored follow-up for patients after percutaneous pulmonary valve implantation.

[1]  B Geiger,et al.  Dynamic flat panel detector versus image intensifier in cardiac imaging: dose and image quality , 2005, Physics in medicine and biology.

[2]  A. Taylor,et al.  Risk Stratification, Systematic Classification, and Anticipatory Management Strategies for Stent Fracture After Percutaneous Pulmonary Valve Implantation , 2007, Circulation.

[3]  Silvia Schievano,et al.  Finite element analysis of stent deployment: understanding stent fracture in percutaneous pulmonary valve implantation. , 2007, Journal of interventional cardiology.

[4]  A. Taylor,et al.  Percutaneous pulmonary valve-in-valve implantation: a successful treatment concept for early device failure. , 2008, European heart journal.

[5]  A. Taylor,et al.  Percutaneous pulmonary valve implantation: an update , 2009, Expert review of cardiovascular therapy.

[6]  J. Cheatham,et al.  Short- and Medium-Term Outcomes After Transcatheter Pulmonary Valve Placement in the Expanded Multicenter US Melody Valve Trial , 2010, Circulation.

[7]  A. Taylor,et al.  Pre-stenting with a bare metal stent before percutaneous pulmonary valve implantation: acute and 1-year outcomes , 2010, Heart.

[8]  Silvia Schievano,et al.  Patient specific finite element analysis results in more accurate prediction of stent fractures: application to percutaneous pulmonary valve implantation. , 2010, Journal of biomechanics.

[9]  T. Kuehne,et al.  Percutaneous pulmonary valve implantation: two-centre experience with more than 100 patients. , 2011, European heart journal.

[10]  M. Demkow,et al.  Percutaneous pulmonary valve implantation preceded by routine prestenting with a bare metal stent , 2011, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[11]  J. Cheatham,et al.  Stent Fracture, Valve Dysfunction, and Right Ventricular Outflow Tract Reintervention After Transcatheter Pulmonary Valve Implantation: Patient-Related and Procedural Risk Factors in the US Melody Valve Trial , 2011, Circulation. Cardiovascular interventions.

[12]  L. Iserin,et al.  Outcomes and safety of transcatheter pulmonary valve replacement in patients with large patched right ventricular outflow tracts. , 2012, Archives of cardiovascular diseases.

[13]  P. D. del Nido,et al.  Clinical and Stent-Related Outcomes After Transcatheter or Operative Placement of Bare-Metal Stents in the Ventricular Septum or Subvalvar Systemic Outflow Tract , 2012, Circulation. Cardiovascular interventions.

[14]  K. Hill,et al.  Percutaneous pulmonary valve replacement , 2012 .

[15]  M. Chessa,et al.  PEDIATRIC AND CONGENITAL HEART DISEASE Original Studies Melody Transcatheter Pulmonary Valve Implantation. Results from the Registry of the Italian Society of Pediatric Cardiology , 2013 .

[16]  Silvia Schievano,et al.  Uncertainty assessment of imaging techniques for the 3D reconstruction of stent geometry. , 2014, Medical engineering & physics.