Fourier rebinning of time-of-flight PET data

This paper explores fast reconstruction strategies for 3D time-of-flight (TOF) positron emission tomography (PET), based on 2D data rebinning. Starting from pre-corrected 3D TOF data, a rebinning algorithm estimates for each transaxial slice the 2D TOF sinogram that would have been acquired by a single-ring scanner. The rebinned sinograms can then be reconstructed using any algorithm for 2D TOF reconstruction. We introduce TOF-FORE, an approximate rebinning algorithm obtained by extending the Fourier rebinning method for non-TOF data. In addition, we identify two partial differential equations that must be satisfied by consistent 3D TOF data, and use them to derive exact rebinning algorithms and to characterize the degree of the approximation in TOF-FORE. Numerical simulations demonstrate that TOF-FORE is more accurate than two different TOF extensions of the single-slice rebinning method, and suggest that TOF-FORE will be a valuable tool for practical TOF PET in the range of axial apertures and time resolutions typical of current scanners.

[1]  F. John The ultrahyperbolic differential equation with four independent variables , 1938 .

[2]  Victor J. Sank,et al.  POTENTIAL ADVANTAGES OF A CESIUM FLUORIDE SCINTILLATOR FOR A TIME‐OF‐FLIGHT POSITRON CAMERA , 1980, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[3]  Takehiro Tomitani Image Reconstruction and Noise Evaluation in Photon Time-of-Flight Assisted Positron Emission Tomography , 1981 .

[4]  L. J. Thomas,et al.  A Matheematical Model for Positron-Emission Tomography Systems Having Time-of-Flight Measurements , 1981, IEEE Transactions on Nuclear Science.

[5]  Donald L. Snyder Some Noise Comparisons of Data-Collection Arrays for Emission Tomography-Systems Having Time-of-Flight Measurements , 1982, IEEE Transactions on Nuclear Science.

[6]  Michel M. Ter-Pogossian,et al.  Super PETT I: A Positron Emission Tomograph Utilizing Photon Time-of-Flight Information , 1982 .

[7]  N. Mullani,et al.  Sensitivity Improvement of TOFPET by the Utilization of the Inter-Slice Coincidences , 1982, IEEE Transactions on Nuclear Science.

[8]  W. Wong,et al.  Preliminary Results with TOFPET , 1983, IEEE Transactions on Nuclear Science.

[9]  Donald L. Snyder,et al.  Image Reconstruction from List-Mode Data in an Emission Tomography System Having Time-of-Flight Measurements , 1983, IEEE Transactions on Nuclear Science.

[10]  Chin-Tu Chen,et al.  A Simplified EM Reconstruction Algorithm for TOFPET , 1985, IEEE Transactions on Nuclear Science.

[11]  M. Daube-Witherspoon,et al.  An Iterative Image Space Reconstruction Algorthm Suitable for Volume ECT , 1986, IEEE Transactions on Medical Imaging.

[12]  M. Daube-Witherspoon,et al.  Treatment of axial data in three-dimensional PET. , 1987, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[13]  B. Mazoyer,et al.  Physical characteristics of TTV03, a new high spatial resolution time-of-flight positron tomograph , 1990 .

[14]  P. Grangeat,et al.  Three-dimensional PET reconstruction with time-of-flight measurement. , 1992, Physics in medicine and biology.

[15]  Reconstruction 3D directe pour la tomographie par émission de positons avec mesure du temps de vol , 1993 .

[16]  M. Defrise A factorization method for the 3D X-ray transform , 1995 .

[17]  Michel Defrise,et al.  Fast iterative image reconstruction of 3D PET data , 1996, 1996 IEEE Nuclear Science Symposium. Conference Record.

[18]  Lucas C. Parra,et al.  List-Mode Likelihood EM Algorithm and Noise Estimation Demonstrated on 2D-PET , 1998, IEEE Trans. Medical Imaging.

[19]  M. Defrise,et al.  A fast rebinning algorithm for 3D positron emission tomography using John's equation , 1999 .

[20]  W. Moses,et al.  Prospects for time-of-flight PET using LSO scintillator , 1999 .

[21]  C. Comtat,et al.  Exact rebinning methods for three-dimensional PET , 1999, IEEE Transactions on Medical Imaging.

[22]  Samuel Matej,et al.  2.5-D simultaneous multislice reconstruction by series expansion methods from Fourier-rebinned PET data , 2000, IEEE Transactions on Medical Imaging.

[23]  Xuan Liu,et al.  Comparison of 3-D reconstruction with 3D-OSEM and with FORE+OSEM for PET , 2001, IEEE Transactions on Medical Imaging.

[24]  W. Moses Time of flight in PET revisited , 2003 .

[25]  S. Glick,et al.  3D PET list-mode iterative reconstruction using time-of-flight information , 2004, IEEE Symposium Conference Record Nuclear Science 2004..

[26]  G. Muehllehner,et al.  Design of a lanthanum bromide detector for time-of-flight PET , 2004, IEEE Transactions on Nuclear Science.

[27]  G Muehllehner,et al.  Image quality assessment of LaBr3-based whole-body 3D PET scanners: a Monte Carlo evaluation , 2004 .