Design and Performance of an Acquisition and Control System for a Positron Camera with Novel Detectors

A Sun-based data acquisition and control (DAQ) system has been designed for PETRRA, a whole-body positron camera using novel large-area detectors. The DAQ system uses a high-speed digital I/O card (S16D) installed on the SBus of a SPARC10 and a specially-designed Positron Camera Interface (PCI), which also controls the gantry and horizontal couch motion. Data in the form of different types of B-byte packets are acquired in list mode. Tests with a signal generator show that the DAQ system should be able to accommodate coincidence count-rates up to 100 kcps. The predicted count loss due to the DAQ system is /spl sim/13% at this count rate, provided asynchronous-read based software is used. The list-mode data acquisition system designed for PETRRA could be adapted for other 3D PET cameras with similar data rates, including dual-headed gamma cameras operating in coincidence mode.

[1]  G. Knoll Radiation detection and measurement , 1979 .

[2]  R. Stephenson,et al.  The development of MWPC-based systems for imaging X-rays, gamma rays and charged particles in applications in medicine, materials science and biochemistry: Part II. Applications in medicine, biology, low energy and X-ray physics , 1983 .

[3]  D. Townsend,et al.  Increased sensitivity and field of view for a rotating positron camera. , 1984, Physics in Medicine and Biology.

[4]  M. S. Atkins,et al.  A tomograph VMEbus parallel processing data acquisition system , 1989 .

[5]  S. Webb,et al.  The performance of a multiwire proportional chamber positron camera for clinical use. , 1989, Physics in medicine and biology.

[6]  R. Douet,et al.  A VME multiprocessor data acquisition system combining a UNIX workstation and real-time microprocessors , 1990 .

[7]  J. Macphail,et al.  Data acquisition for a medical imaging MWPC detector , 1991 .

[8]  E.J. Hoffman,et al.  High sensitivity, total body PET scanning using 3D data acquisition and reconstruction , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[9]  M. S. Atkins,et al.  Use of transputers in a 3-D positron emission tomograph , 1991 .

[10]  A. H. Ullings,et al.  A UNIX-based real-time data acquisition system for microprobe analysis using an advanced X11 window toolkit , 1993 .

[11]  Y. Yasu,et al.  Development of a data acquisition system using a RISC/UNIXTM workstation , 1993 .

[12]  D. Visvikis,et al.  Performance of a BaF/sub 2/-TMAE prototype detector for use in PET , 1994 .

[13]  D. Visvikis,et al.  PETRRA: preliminary experimental results from the first full size detector and dead time simulation of the count rate performance of a unique whole body PET camera , 1995 .

[14]  D. Visvikis,et al.  PERFORMANCE CHARACTERISATION OF LARGE AREA BAF2-TMAE DETECTORS FOR USE IN A WHOLE BODY CLINICAL PET CAMERA , 1997 .