Occupational dose in interventional radiology procedures.

OBJECTIVE Interventional radiology tends to involve long procedures (i.e., long fluoroscopic times). Therefore, radiation protection for interventional radiology staff is an important issue. This study describes the occupational radiation dose for interventional radiology staff, especially nurses, to clarify the present annual dose level for interventional radiology nurses. MATERIALS AND METHODS We compared the annual occupational dose (effective dose and dose equivalent) among interventional radiology staff in a hospital where 6606 catheterization procedures are performed annually. The annual occupational doses of 18 physicians, seven nurses, and eight radiologic technologists were recorded using two monitoring badges, one worn over and one under their lead aprons. RESULTS The annual mean ± SD effective dose (range) to the physicians, nurses, and radiologic technologists using two badges was 3.00 ± 1.50 (0.84-6.17), 1.34 ± 0.55 (0.70-2.20), and 0.60 ± 0.48 (0.02-1.43) mSv/y, respectively. Similarly, the annual mean ± SD dose equivalent range was 19.84 ± 12.45 (7.0-48.5), 4.73 ± 0.72 (3.9-6.2), and 1.30 ± 1.00 (0.2-2.7) mSv/y, respectively. The mean ± SD effective dose for the physicians was 1.02 ± 0.74 and 3.00 ± 1.50 mSv/y for the one- and two-badge methods, respectively (p < 0.001). Similarly, the mean ± SD effective dose for the nurses (p = 0.186) and radiologic technologists (p = 0.726) tended to be lower using the one-badge method. CONCLUSION The annual occupational dose for interventional radiology staff was in the order physicians > nurses > radiologic technologists. The occupational dose determined using one badge under the apron was far lower than the dose obtained with two badges in both physicians and nonphysicians. To evaluate the occupational dose correctly, we recommend use of two monitoring badges to evaluate interventional radiology nurses as well as physicians.

[1]  K. Koshida,et al.  Investigation of Qualitative and Quantitative Factors Related to Radiological Exposure to Nursing Staff During Computed Tomography Examinations , 2014, Health physics.

[2]  Stephen Balter,et al.  Medical imaging using ionizing radiation: optimization of dose and image quality in fluoroscopy. , 2013, Medical physics.

[3]  F. Mettler,et al.  Skin injuries from fluoroscopically guided procedures: part 2, review of 73 cases and recommendations for minimizing dose delivered to patient. , 2001, AJR. American journal of roentgenology.

[4]  M. Walsh,et al.  Radiation safety in the practice of cardiology , 1998 .

[5]  Stephen Balter,et al.  Fluoroscopically guided interventional procedures: a review of radiation effects on patients' skin and hair. , 2010, Radiology.

[6]  J. Jansen,et al.  Overview of double dosimetry procedures for the determination of the effective dose to the interventional radiology staff. , 2008, Radiation protection dosimetry.

[7]  C. Martin,et al.  Assessment of eye and body dose for interventional radiologists, cardiologists, and other interventional staff , 2013, Journal of radiological protection : official journal of the Society for Radiological Protection.

[8]  Masayuki Zuguchi,et al.  Does digital acquisition reduce patients' skin dose in cardiac interventional procedures? An experimental study. , 2004, AJR. American journal of roentgenology.

[9]  M. Kitagawa,et al.  The dose and risk factors for radiation exposure to medical staff during endobronchial ultrasonography with a guide sheath for peripheral pulmonary lesions under X-ray fluoroscopy. , 2014, Japanese journal of clinical oncology.

[10]  E. Vañó,et al.  Eye lens exposure to radiation in interventional suites: caution is warranted. , 2008, Radiology.

[11]  Masayuki Zuguchi,et al.  Radiation dose to the pediatric cardiac catheterization and intervention patient. , 2010, AJR. American journal of roentgenology.

[12]  L. Dauer,et al.  Fears, feelings, and facts: interactively communicating benefits and risks of medical radiation with patients. , 2011, AJR. American journal of roentgenology.

[13]  C. Muirhead,et al.  Radiation Cataractogenesis: A Review of Recent Studies , 2009, Radiation research.

[14]  Masayuki Zuguchi,et al.  Relationship between fluoroscopic time, dose-area product, body weight, and maximum radiation skin dose in cardiac interventional procedures. , 2006, AJR. American journal of roentgenology.

[15]  Paul Keall,et al.  Dynamic keyhole: a novel method to improve MR images in the presence of respiratory motion for real-time MRI. , 2014, Medical physics.

[16]  Masayuki Zuguchi,et al.  Total entrance skin dose: an effective indicator of maximum radiation dose to the skin during percutaneous coronary intervention. , 2007, AJR. American journal of roentgenology.

[17]  J. Moses,et al.  Radiation is not the only risk. , 2011, AJR. American journal of roentgenology.

[18]  K. Chida,et al.  Clarifying and visualizing sources of staff-received scattered radiation in interventional procedures. , 2011, AJR. American journal of roentgenology.

[19]  X. L. Velders,et al.  Effective dose to staff from interventional procedures: estimations from single and double dosimetry. , 2009, Radiation protection dosimetry.

[20]  Y. Harima,et al.  Radiation dose of nurses during IR procedures: a controlled trial evaluating operator alerts before nursing tasks. , 2014, Journal of vascular and interventional radiology : JVIR.

[21]  R. Sievert,et al.  Book Reviews : Recommendations of the International Commission on Radiological Protection (as amended 1959 and revised 1962). I.C.R.P. Publication 6. 70 pp. PERGAMON PRESS. Oxford, London and New York, 1964. £1 5s. 0d. [TB/54] , 1964 .

[22]  E P Efstathopoulos,et al.  Occupational radiation doses to the extremities and the eyes in interventional radiology and cardiology procedures. , 2011, The British journal of radiology.

[23]  Masayuki Zuguchi,et al.  Radiation dose of interventional radiology system using a flat-panel detector. , 2009, AJR. American journal of roentgenology.

[24]  S. Takahashi,et al.  Effect of radiation monitoring method and formula differences on estimated physician dose during percutaneous coronary intervention , 2009, Acta radiologica.

[25]  F. Mettler,et al.  Skin injuries from fluoroscopically guided procedures: part 1, characteristics of radiation injury. , 2001, AJR. American journal of roentgenology.