APPLICATION OF 3‐D FINITE DIFFERENCE METHOD FOR INDUCTANCE CALCULATION OF AIR‐CORE COILS SYSTEM
暂无分享,去创建一个
The paper deals with the inductance calculation of air‐core coils system by means of 3‐D analysis of magnetic field of the coils with rectangular cross‐section. The possibility of mutual and self‐inductance calculation is presented. For magnetic field calculation, the Finite Difference Method with application of fast calculating procedures was applied. The method of calculation has been verified by experiments. The obtained difference between calculating and measurement results is equal to a few percent. The computer program is usefull especially for asymmetrical configuration of the coils.
[1] M. Lukaniszyn,et al. Three-dimensional model of three-phase transformer for leakage field calculation , 1990 .
[2] M. Lukaniszyn,et al. 3‐D CALCULATION OF MAGNETIC AND ELECTRIC FIELDS BY FDM USING FAST SOLVING SUBROUTINES , 1992 .
[3] 3-D Reactance Calculation of Air-Core Coils with Magnetic Screening , 1988 .