Low frequency ripple current compensation with DC active filter for the single-phase aeronautic static inverter

The second order harmonic current drawn by the main part of single-phase aeronautic static inverter which is a typical load in the aircraft power system deteriorates the power quality of aeronautic high voltage power system. In this paper, the low frequency harmonic propagation which is hard to be filtered by the passive components is studied. In order to maintain a good power quality, a DC active power filter (DC-APF) is proposed to be installed in parallel with the aeronautic static inverter, producing the low-frequency current for the load. A novel DC-APF based on the “dual switch” topology is proposed in this paper. This novel configuration is suitable for the aircraft power system with the requirement of high reliability for its inherent “no shoot-through” behavior, optimization of the devices and good comprehensive performance. Control strategy of this con-figuration and discussion about the modeling analysis are given as well. Experimental results are shown to verify the good harmonic compensation characteristic.

[1]  D.C. Hamill An efficient active ripple filter for use in DC-DC conversion , 1996, IEEE Transactions on Aerospace and Electronic Systems.

[2]  B.H. Cho,et al.  Small signal modeling of hysteretic current mode control using the PWM switch model , 2006, 2006 IEEE Workshops on Computers in Power Electronics.

[3]  R. Gemmen Analysis for the Effect of Inverter Ripple Current on Fuel Cell Operating Condition , 2001, Heat Transfer: Volume 4 — Combustion and Energy Systems.

[4]  Kun Xing Modeling, Analysis, and Design of Distributed Power Electronics System Based on Building Block Concept , 1999 .

[5]  Wang Jianhua,et al.  Modeling and Analysis of Hysteretic Current Mode Control Inverter , 2009, 2009 Twenty-Fourth Annual IEEE Applied Power Electronics Conference and Exposition.

[6]  Hirofumi Akagi,et al.  Instantaneous Reactive Power Compensators Comprising Switching Devices without Energy Storage Components , 1984, IEEE Transactions on Industry Applications.

[7]  Jinjun Liu,et al.  Novel load ripple voltage-controlled parallel DC active power filters for high performance magnet power supplies , 2006 .

[8]  M. B. Dewe,et al.  Harmonic measurements made on the upgraded New Zealand inter-island HVDC transmission system , 1994 .

[9]  J.A. Ortega,et al.  Moving towards a more electric aircraft , 2007, IEEE Aerospace and Electronic Systems Magazine.

[10]  David J. Perreault,et al.  Design and evaluation of a hybrid passive/active ripple filter with voltage injection , 2003 .

[11]  G. Asplund,et al.  Active DC filter for HVDC system-a test installation in the Konti-Skan DC link at Lindome converter station , 1993 .

[12]  J.-i. Itoh,et al.  Ripple Current Reduction of a Fuel Cell for a Single-Phase Isolated Converter Using a DC Active Filter With a Center Tap , 2009, IEEE Transactions on Power Electronics.

[13]  S.K. Mazumder,et al.  A Ripple-Mitigating and Energy-Efficient Fuel Cell Power-Conditioning System , 2007, IEEE Transactions on Power Electronics.