Measurement accuracy of the flow velocity in pulsed ultrasound Doppler velocimeter.

This paper presents a numerical simulation method for evaluating the measurement accuracy of the high-frequency pulsed ultrasound Doppler velocimeter (PUDV). The frequency distribution of the Doppler signal from a sample volume is calculated by dividing the sample volume into small cells and using the statistics of the velocities of the cells. The distribution is used to analyze the accuracy of the poststenotic velocity measurements of a 20-MHz 80-channel PUDV. The target flow field is obtained by solving Navier-Stokes equations numerically. It was shown that the velocities evaluated by the zero-cross and Fourier transform methods agreed well with the given velocities, and that flow separation was successfully detected. It was also shown that the tube diameter should be at least twice as large as the diameter of the sample volume to obtain accurate measurements.

[1]  D R Pedersen,et al.  A three-dimensional computational simulation of some sources of measurement artifact in microvascular pulsed ultrasound Doppler velocimetry. , 1985, Journal of biomechanical engineering.

[2]  F. Kajiya,et al.  In-vivo measurements of blood flow velocity profiles in canine ilio-femoral anastomotic bypass grafts. , 1997, Journal of biomechanical engineering.

[3]  R. Gill Measurement of blood flow by ultrasound: accuracy and sources of error. , 1985, Ultrasound in medicine & biology.

[4]  Blood velocity profiles in the human renal artery by Doppler ultrasound and their relationship to atherosclerosis. , 1996, Arteriosclerosis, thrombosis, and vascular biology.

[5]  D. F. Young,et al.  Flow characteristics in models of arterial stenoses. I. Steady flow. , 1973, Journal of biomechanics.

[6]  M. Marcus,et al.  Measurements of Coronary Velocity and Reactive Hyperemia in the Coronary Circulation of Humans , 1981, Circulation research.

[7]  F. Kajiya,et al.  Evaluation of human coronary blood flow with an 80 channel 20 MHz pulsed Doppler velocimeter and zero-cross and Fourier transform methods during cardiac surgery. , 1986, Circulation.

[8]  J. S. Cole,et al.  An ultrasonic pulsed Doppler system for measuring blood flow in small vessels. , 1974, Journal of applied physiology.

[9]  F. Kajiya,et al.  Blood velocity distributions within intact canine arterial bifurcations. , 1992, The American journal of physiology.

[10]  V. Newhouse,et al.  Ultrasound Doppler Probing of Flows Transverse with Respect to Beam Axis , 1987, IEEE Transactions on Biomedical Engineering.

[11]  Jean-Yves Chapelon,et al.  THE TRANSVERSE DOPPLER SPECTRUM FOR FOCUSED TRANSDUCERS WITH RECTANGULAR APERTURES , 1994 .