3D quantitative imaging of the microvasculature with the Texas Instruments Digital Micromirror Device

There is a growing need for developing 3D quantitative imaging tools that can operate at high speed enabling real-time visualization for the field of biology, material science, and the semiconductor industry. We will present our 3D quantitative imaging system based on a confocal microscope built with a Texas Instruments Digital Micromirror Device (DMD). By using the DMD as a spatial light modulator, confocal transverse surface (x, y) scanning can be performed in parallel at speeds faster than video rate without physical movement of the sample. The DMD allows us to programmably configure the source and the detection pinhole array in the lateral direction to achieve the best signal and to reduce the crosstalk noise. Investigations of the microcirculation were performed on 40 g to 45 g golden Syrian hamsters fit with dorsal skin fold window chambers. FITC-Dextran or Red blood cells from donor hamsters, stained with Celltracker CM-DiI, were injected into the circulation and imaged with the confocal microscope. We will present the measured results for the axial resolution, in vivo, as well as experimental results from imaging the window chamber.

[1]  P. Johnson,et al.  Changes in resistance vessels during hemorrhagic shock and resuscitation in conscious hamster model. , 1999, The American journal of physiology.

[2]  T Wilson,et al.  Experimental observations of the depth-discrimination properties of scanning microscopes. , 1981, Optics letters.

[3]  M. Liang,et al.  Confocal pattern period in multiple-aperture confocal imaging systems with coherent illumination. , 1997, Optics letters.

[4]  T. Jovin,et al.  An optical sectioning programmable array microscope implemented with a digital micromirror device , 1999, Journal of microscopy.

[5]  Elliot L. Botvinick,et al.  3D profilometry using a dynamically configurable confocal microscope , 1999, Electronic Imaging.

[6]  Jeffrey B. Sampsell,et al.  Digital micromirror device and its application to projection displays , 1994 .

[7]  J Schwider,et al.  Confocal microscopy with a refractive microlens-pinhole array. , 1998, Optics letters.

[8]  K. Messmer,et al.  Technical report—a new chamber technique for microvascular studies in unanesthetized hamsters , 1980, Research in experimental medicine. Zeitschrift fur die gesamte experimentelle Medizin einschliesslich experimenteller Chirurgie.

[9]  M. Bertero,et al.  Super-resolution in confocal scanning microscopy: III. The case of circular pupils , 1991 .

[10]  David R. Sandison,et al.  Quantitative Fluorescence Confocal Laser Scanning Microscopy (CLSM) , 1995 .

[11]  T. Jovin,et al.  Theory of confocal fluorescence imaging in the programmable array microscope (PAM) , 1998 .