Point of Connection Voltage Regulation Strategies for AC Connected Large Offshore Wind Farms

The offshore wind energy generation industry is developing rapidly in the UK. The long submarine cable connection needed between the wind turbine generators and the onshore Point of Connection (PoC) introduces additional difficulties for compliance with the GB Grid Code reactive power requirement. To address this problem, this paper investigates different PoC voltage regulation strategies. The methods are compared in terms of control requirements, fault behaviour of the wind farm and economics. It is shown that for long connection distances to the PoC, additional dynamic reactive compensation equipment and/or a tap-changing transformer at the offshore platform will probably be needed for Grid Code Compliance. It is shown that a strategy where a STATCOM solely regulates the PoC voltage, leads to increased capital expenditure. However, this provides advantages in respect to its simplicity, speed of PoC voltage regulation and wind turbine behaviour for a fault at the PoC.

[1]  Derek Alien Powering the nation , 2007 .

[2]  Frede Blaabjerg,et al.  Transient stability of DFIG wind turbines at an external short‐circuit fault , 2005 .

[3]  M. Barnes,et al.  Modelling and GB Grid Code Compliance Studies of Offshore Wind Farms with Doubly-Fed Induction Generators , 1988 .

[4]  Vladislav Akhmatov Variable-speed Wind Turbines with Doubly-fed Induction Generators Part II: Power System Stability , 2002 .

[5]  Nicholas Jenkins,et al.  Comparison of fixed speed and doubly-fed induction wind turbines during power system disturbances , 2003 .

[6]  James F. Manwell,et al.  TRANSMISSION OPTIONS FOR OFFSHORE WIND FARMS IN THE UNITED STATES , 2002 .

[7]  Vladislav Akhmatov Variable-Speed Wind Turbines with Doubly-Fed Induction Generators Part IV: Uninterrupted Operation Features at Grid Faults with Converter Control Coordination , 2003 .

[8]  J. Svensson,et al.  Vector current controlled voltage source converter-deadbeat control and saturation strategies , 2002 .

[9]  M. Heathcote The J&P Transformer Book: A Practical Technology of the Power Transformer , 1998 .

[10]  Stefan Lundberg Performance comparison of wind park configurations , 2003 .

[11]  R. W. De Doncker,et al.  Doubly fed induction generator systems for wind turbines , 2002 .

[12]  J. Morren,et al.  Ridethrough of wind turbines with doubly-fed induction generator during a voltage dip , 2005, IEEE Transactions on Energy Conversion.

[13]  Vladislav Akhmatov,et al.  Variable-Speed Wind Turbines with Doubly-Fed Induction Generators , 2002 .

[14]  Marion Kee,et al.  Analysis , 2004, Machine Translation.

[15]  Lazaros Lazaridis Economic Comparison of HVAC and HVDCSolutions for Large Offshore Wind Farms underSpecial Consideration of Reliability , 2005 .

[16]  Nicholas Jenkins,et al.  Co-ordinated voltage control strategy for a doubly-fed induction generator (DFIG)-based wind farm , 2004 .