Exergy analysis of industrial waste heat recovery based ejector vapour compression refrigeration system

AbstractThis communication employed a thermodynamic analysis through energy and exergy for the performance evaluation of waste heat recovery based ejector compression refrigeration in which internal heat exchanger and cooler are used to enhance the performance of the cycle. The system is an integration of the Rankine power cycle and the compression refrigeration cycle. A comprehensive parametric study is performed to investigate the effects of exhaust gas inlet temperature, pinch point (PP) and evaporator temperature on the energetic and exergetic coefficient of performance (COP) of the system as well on the exergy destruction in each component. It is shown that the exergetic COP of the system decreases significantly with the increase in exhaust gas temperature and PP, while the energetic COP increases slightly. The effect of evaporator temperature also shows a similar behaviour. It is further shown that the exergetic coefficient of performance of the system is ∼75% lower than the COP of the same system. ...

[1]  A. Bejan Fundamentals of exergy analysis, entropy generation minimization, and the generation of flow architecture , 2002 .

[2]  Meherwan P. Boyce,et al.  Heat Recovery Steam Generators , 2010 .

[3]  Syed M. Zubair,et al.  Design and rating of an integrated mechanical-subcooling vapor-compression refrigeration system , 2000 .

[4]  Ho-Young Kwak,et al.  Exergy analysis for a gas turbine cogeneration system , 1996 .

[5]  E. Nehdi,et al.  Performance analysis of the vapour compression cycle using ejector as an expander , 2007 .

[6]  Ibrahim Dincer,et al.  Exergy Analysis of an Industrial Waste Heat Recovery Based Cogeneration Cycle for Combined Production of Power and Refrigeration , 2009 .

[7]  Manuel Valdés,et al.  Optimization of heat recovery steam generators for combined cycle gas turbine power plants , 2001 .

[8]  Eckhard A. Groll,et al.  Efficiencies of transcritical CO2 cycles with and without an expansion turbine , 1998 .

[9]  B. Agnew,et al.  Exergy analysis: an absorption refrigerator using lithium bromide and water as the working fluids , 2000, Applied Thermal Engineering.

[10]  Jahar Sarkar,et al.  Optimization of two-stage transcritical carbon dioxide heat pump cycles , 2007 .

[11]  Bin-Juine Huang,et al.  Ejector Performance Characteristics and Design Analysis of Jet Refrigeration System , 1985 .

[12]  P. K. Nag,et al.  Performance simulation of heat recovery steam generators in a cogeneration system , 1998 .

[13]  Abdul Khaliq,et al.  Combined first and second-law analysis of gas turbine cogeneration system with inlet air cooling and evaporative aftercooling of the compressor discharge , 2007 .

[14]  S. Klein,et al.  NIST Standard Reference Database 23: NIST Thermodynamic and Transport Properties of Refrigerants and Refrigerant Mixtures-REFPROP, Version 6.0 | NIST , 1998 .

[15]  Alan A. Kornhauser,et al.  The Use of an Ejector as a Refrigerant Expander , 1990 .

[16]  Michel Feidt,et al.  Comparison of the working domains of some compression heat pumps and a compression-absorption heat pump , 1997 .

[17]  Bin-Juine Huang,et al.  A 1-D analysis of ejector performance , 1999 .

[18]  Piotr A. Domanski,et al.  Theoretical Evaluation of the Vapor Compression Cycle With a Liquid-Line/Suction-Line Heat Exchanger, Economizer, and Ejector (NISTIR 5606) , 1995 .

[19]  W. B. Gosney Principles of Refrigeration , 1982 .