Evaluation of Scintillator Detection Materials for Application within Airborne Environmental Radiation Monitoring

In response to the Fukushima Daiichi Nuclear Power Plant accident, there has occurred the unabated growth in the number of airborne platforms developed to perform radiation mapping—each utilising various designs of a low-altitude uncrewed aerial vehicle. Alongside the associated advancements in the airborne system transporting the radiation detection payload, from the earliest radiological analyses performed using gas-filled Geiger-Muller tube detectors, modern radiation detection and mapping platforms are now based near-exclusively on solid-state scintillator detectors. With numerous varieties of such light-emitting crystalline materials now in existence, this combined desk and computational modelling study sought to evaluate the best-available detector material compatible with the requirements for low-altitude autonomous radiation detection, localisation and subsequent high spatial-resolution mapping of both naturally occurring and anthropogenically-derived radionuclides. The ideal geometry of such detector materials is also evaluated. While NaI and CsI (both elementally doped) are (and will likely remain) the mainstays of radiation detection, LaBr3 scintillation detectors were determined to possess not only a greater sensitivity to incident gamma-ray radiation, but also a far superior spectral (energy) resolution over existing and other potentially deployable detector materials. Combined with their current competitive cost, an array of three such composition cylindrical detectors were determined to provide the best means of detecting and discriminating the various incident gamma-rays.

[1]  T. Scott,et al.  Airborne radiation mapping: overview and application of current and future aerial systems , 2016 .

[2]  A. K. Singh,et al.  Pulse shape discrimination properties of Gd 3 Ga 3 Al 2 O 12 :Ce,B single crystal in comparison with CsI:Tl , 2016 .

[3]  T. Niedermayr,et al.  Scintillators With Potential to Supersede Lanthanum Bromide , 2009, IEEE Transactions on Nuclear Science.

[4]  T. Scott,et al.  Application of airborne photogrammetry for the visualisation and assessment of contamination migration arising from a Fukushima waste storage facility. , 2018, Environmental pollution.

[5]  H.W. Kraner,et al.  Radiation detection and measurement , 1981, Proceedings of the IEEE.

[6]  John S. Fardoulis,et al.  Low altitude unmanned aerial vehicle for characterising remediation effectiveness following the FDNPP accident. , 2016, Journal of environmental radioactivity.

[7]  D. Shaw,et al.  IUPAC-NIST SOLUBILITY DATA SERIES , 2005 .

[8]  Y. Yamashiki,et al.  Radiological comparison of a FDNPP waste storage site during and after construction. , 2018, Environmental pollution.

[9]  J. Pitkin,et al.  Design parameters for aerial gamma‐ray surveys , 1980 .

[10]  B. Seitz,et al.  Energy Resolution and Temperature Dependence of Ce:GAGG Coupled to Silicon Photomultipliers , 2016 .

[11]  A. Dell'Acqua,et al.  Geant4 - A simulation toolkit , 2003 .

[12]  Yukihisa Sanada,et al.  Aerial radiation monitoring around the Fukushima Dai-ichi Nuclear Power Plant using an unmanned helicopter. , 2015, Journal of environmental radioactivity.

[13]  E. Scott,et al.  Accounting for spatial variability and fields of view in environmental gamma ray spectrometry , 1996 .

[14]  Georg Steinhauser,et al.  Comparison of the Chernobyl and Fukushima nuclear accidents: a review of the environmental impacts. , 2014, The Science of the total environment.

[15]  Y. Yokota,et al.  Development of a Prototype Detector Using APD-Arrays Coupled With Pixelized Ce:GAGG Scintillator for High Resolution Radiation Imaging , 2014, IEEE Transactions on Nuclear Science.

[16]  P. Menge,et al.  Lanthanum halide scintillators: Properties and applications , 2006 .

[17]  Lubomír Gryc,et al.  Mapping of radiation anomalies using UAV mini-airborne gamma-ray spectrometry. , 2018, Journal of environmental radioactivity.

[18]  J. B. Birks,et al.  The Theory and Practice of Scintillation Counting , 1965 .

[19]  Ding Yuan,et al.  CeBr3 as a room-temperature, high-resolution gamma-ray detector , 2009 .

[20]  Kevin Kochersberger,et al.  Radiation Mapping in Post-Disaster Environments Using an Autonomous Helicopter , 2012, Remote. Sens..

[21]  Jin-sheng Wang,et al.  Sources of anthropogenic radionuclides in the environment: a review. , 2010, Journal of environmental radioactivity.

[22]  John S. Fardoulis,et al.  The use of unmanned aerial systems for the mapping of legacy uranium mines. , 2015, Journal of environmental radioactivity.

[23]  B. Seitz,et al.  Energy Resolution and Temperature Dependence of Ce:GAGG Coupled to ${\hbox {3}}\ \hbox{mm} \times {\hbox {3}}\ \hbox{mm}$ Silicon Photomultipliers , 2016, IEEE Transactions on Nuclear Science.

[24]  J. Iwanowska,et al.  Characterization of new GAGG:Ce scintillators with different Al-to-Ga ratio , 2013, 2013 IEEE Nuclear Science Symposium and Medical Imaging Conference (2013 NSS/MIC).

[25]  P. Dorenbos,et al.  Scintillation and detection characteristics of high-sensitivity CeBr3 gamma-ray spectrometers , 2013 .

[26]  T. Scott,et al.  Lightweight aerial vehicles for monitoring, assessment and mapping of radiation anomalies. , 2014, Journal of environmental radioactivity.

[27]  Peter R. Menge,et al.  Performance of large lanthanum bromide scintillators , 2007 .

[28]  M. I. Ojovan,et al.  Radioactive waste management and contaminated site clean-up : processes, technologies and international experience , 2013 .