A novel biosensor array with a wheel-like pattern for glucose, lactate and choline based on electrochemiluminescence imaging.

Electrochemiluminescence (ECL) imaging provides a superior approach to achieve array detection because of its ability for ultrasensitive multiplex analysis. In this paper, we reported a novel ECL imaging biosensor array modified with an enzyme/carbon nanotubes/chitosan composite film for the determination of glucose, choline and lactate. The biosensor array was constructed by integrating a patterned indium tin oxide (ITO) glass plate with six perforated poly(dimethylsiloxane) (PDMS) covers. ECL is generated by the electrochemical reaction between luminol and hydrogen peroxide that is produced by the enzyme catalysed oxidation of different substrates with molecular oxygen, and ECL images were captured by a charge-coupled device (CCD) camera. The separated electrochemical micro-cells enabled simultaneous assay of six samples at different concentrations. From the established calibration curves, the detection limits were 14 μM for glucose, 40 μM for lactate and 97 μM for choline, respectively. Moreover, multicomponent assays and cross reactivity were also studied, both of which were satisfied for the analysis. This biosensing platform based on ECL imaging shows many distinct advantages, including miniaturization, low cost, and multi-functionalization. We believe that this novel ECL imaging biosensor platform will have potential applications in clinical diagnostics, medicine and food inspection.

[1]  Q. Fang,et al.  Integrating bipolar electrochemistry and electrochemiluminescence imaging with microdroplets for chemical analysis. , 2014, Biosensors & bioelectronics.

[2]  Tapio Salmi,et al.  Production of lactic acid/lactates from biomass and their catalytic transformations to commodities. , 2014, Chemical reviews.

[3]  James F Rusling,et al.  High-throughput metabolic genotoxicity screening with a fluidic microwell chip and electrochemiluminescence. , 2013, Lab on a chip.

[4]  Chun-song Zheng,et al.  An electrochemiluminescence sensor for adrenaline assay based on the tyrosinase/SiC/chitosan modified electrode. , 2013, Chemical communications.

[5]  Jing Li,et al.  New insight into a microfluidic-based bipolar system for an electrochemiluminescence sensing platform. , 2013, Analytical chemistry.

[6]  Wipa Suginta,et al.  Electrochemical biosensor applications of polysaccharides chitin and chitosan. , 2013, Chemical reviews.

[7]  Y. Li,et al.  Non-destructive enhancement of latent fingerprints on stainless steel surfaces by electrochemiluminescence. , 2013, The Analyst.

[8]  Jae Ho Shin,et al.  Biocompatible materials for continuous glucose monitoring devices. , 2013, Chemical reviews.

[9]  Jing-Juan Xu,et al.  Electrochemiluminescence on bipolar electrodes for visual bioanalysis , 2013 .

[10]  Zhonglin Zhang,et al.  One-step unipolar pulse electrodeposition of nickel hexacyanoferrate/chitosan/carbon nanotubes film and its application in hydrogen peroxide sensor , 2012 .

[11]  Y. Chai,et al.  Ultrasensitive luminol electrochemiluminescence for protein detection based on in situ generated hydrogen peroxide as coreactant with glucose oxidase anchored AuNPs@MWCNTs labeling. , 2012, Biosensors & bioelectronics.

[12]  W. Marsden I and J , 2012 .

[13]  Behzad Haghighi,et al.  Fabrication of a highly sensitive electrochemiluminescence lactate biosensor using ZnO nanoparticles decorated multiwalled carbon nanotubes. , 2011, Talanta.

[14]  J. Rusling,et al.  Carbon nanotube microwell array for sensitive electrochemiluminescent detection of cancer biomarker proteins. , 2011, Analytical chemistry.

[15]  J. L. Delaney,et al.  Electrogenerated chemiluminescence detection in paper-based microfluidic sensors. , 2011, Analytical chemistry.

[16]  Guobao Xu,et al.  Applications and trends in electrochemiluminescence. , 2010, Chemical Society reviews.

[17]  A. Tonevitsky,et al.  Sol-gel immobilization of lactate oxidase from organic solvent: toward the advanced lactate biosensor. , 2010, Analytical chemistry.

[18]  Wei Wang,et al.  A disposable electrochemical immunosensor for carcinoembryonic antigen based on nano-Au/multi-walled carbon nanotubes-chitosans nanocomposite film modified glassy carbon electrode. , 2010, Analytica chimica acta.

[19]  Hong Dai,et al.  A highly performing electrochemiluminescent biosensor for glucose based on a polyelectrolyte-chitosan modified electrode , 2009 .

[20]  Richard M Crooks,et al.  A large-scale, wireless electrochemical bipolar electrode microarray. , 2009, Journal of the American Chemical Society.

[21]  W. Schuhmann,et al.  Imaging biocatalytic activity of enzyme-polymer spots by means of combined scanning electrochemical microscopy/electrogenerated chemiluminescence. , 2009, Analytical chemistry.

[22]  Neso Sojic,et al.  Multiplexed sandwich immunoassays using electrochemiluminescence imaging resolved at the single bead level. , 2009, Journal of the American Chemical Society.

[23]  M. Oyama,et al.  Fabrication of a colorimetric electrochemiluminescence sensor. , 2009, Analytical chemistry.

[24]  P. Barbara,et al.  Electrogenerated chemiluminescence of single conjugated polymer nanoparticles. , 2008, Journal of the American Chemical Society.

[25]  W. Miao Electrogenerated chemiluminescence and its biorelated applications. , 2008, Chemical reviews.

[26]  Joseph Wang Electrochemical glucose biosensors. , 2008, Chemical reviews.

[27]  Lai-Kwan Chau,et al.  Amperometric L-lactate sensor based on sol-gel processing of an enzyme-linked silicon alkoxide. , 2007, Analytical chemistry.

[28]  G. Shen,et al.  A novel immunoassay strategy based on combination of chitosan and a gold nanoparticle label. , 2007, Talanta.

[29]  S. Krishnan,et al.  Electrochemiluminescent arrays for cytochrome P450-activated genotoxicity screening. DNA damage from benzo[a]pyrene metabolites. , 2007, Analytical chemistry.

[30]  Wei Zhan,et al.  Electrogenerated chemiluminescence. 83. Immunoassay of human C-reactive protein by using Ru(bpy)3(2+)-encapsulated liposomes as labels. , 2007, Analytical chemistry.

[31]  N. Sojic,et al.  Remote NADH imaging through an ordered array of electrochemiluminescent nanoapertures. , 2006, Bioelectrochemistry.

[32]  H. Ju,et al.  Electrogenerated chemiluminescence detection of amino acids based on precolumn derivatization coupled with capillary electrophoresis separation. , 2006, Analytical chemistry.

[33]  S. Dong,et al.  The direct electron transfer of glucose oxidase and glucose biosensor based on carbon nanotubes/chitosan matrix. , 2005, Biosensors & bioelectronics.

[34]  Minghui Yang,et al.  Amperometric biosensor for choline based on layer-by-layer assembled functionalized carbon nanotube and polyaniline multilayer film. , 2005, Analytical biochemistry.

[35]  Christophe A. Marquette,et al.  Screen-printed electrode microarray for electrochemiluminescent measurements , 2005 .

[36]  Maogen Zhang,et al.  Electrochemical sensing platform based on the carbon nanotubes/redox mediators-biopolymer system. , 2005, Journal of the American Chemical Society.

[37]  L. Blum,et al.  Electrochemiluminescent biosensors array for the concomitant detection of choline, glucose, glutamate, lactate, lysine and urate. , 2003, Biosensors & bioelectronics.

[38]  Christophe A. Marquette,et al.  Self-containing reactant biochips for the electrochemiluminescent determination of glucose, lactate and choline , 2003 .

[39]  T. Matsue,et al.  Imaging localized horseradish peroxidase on a glass surface with scanning electrochemical/ chemiluminescence microscopy. , 2001, Analytical biochemistry.

[40]  L. Blum,et al.  Chemiluminescent choline biosensor using histidine-modified peroxidase immobilised on metal-chelate substituted beads and choline oxidase immobilised on anion-exchanger beads co-entrapped in a photocrosslinkable polymer. , 2000, Biosensors & bioelectronics.

[41]  G. Whitesides,et al.  Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane). , 1998, Analytical chemistry.

[42]  T. Yao Flow injection analysis for cholinesterase in blood serum by use of a choline-sensitive electrode as an amperometric detector , 1983 .