Measurement of Blood Pressure Using an Arterial Pulsimeter Equipped with a Hall Device

To measure precise blood pressure (BP) and pulse rate without using a cuff, we have developed an arterial pulsimeter consisting of a small, portable apparatus incorporating a Hall device. Regression analysis of the pulse wave measured during testing of the arterial pulsimeter was conducted using two equations of the BP algorithm. The estimated values of BP obtained by the cuffless arterial pulsimeter over 5 s were compared with values obtained using electronic or liquid mercury BP meters. The standard deviation between the estimated values and the measured values for systolic and diastolic BP were 8.3 and 4.9, respectively, which are close to the range of values of the BP International Standard. Detailed analysis of the pulse wave measured by the cuffless radial artery pulsimeter by detecting changes in the magnetic field can be used to develop a new diagnostic algorithm for BP, which can be applied to new medical apparatus such as the radial artery pulsimeter.

[1]  Sung-Hoon Ahn,et al.  A New Measurement Method of a Radial Pulse Wave Using Multiple Hall Array Devices , 2009 .

[2]  R. Kirkpatrick,et al.  Ambulatory Blood Pressure Monitoring , 1993, The Journal of the American Board of Family Medicine.

[3]  Derac Son,et al.  Development of micro-size search coil magnetometer for magnetic field distribution measurement , 2008 .

[4]  Do-Guwn Hwang,et al.  Embodiment of Spatially Arterial Pulse Diagnostic Apparatus using Array Multiple Hall Devices , 2007 .

[5]  Do-Guwn Hwang,et al.  Improvement of pulse diagnostic apparatus with array sensor of magnetic tunneling junctions , 2006 .

[6]  Do-Guwn Hwang,et al.  Development of spatial pulse diagnostic apparatus with magnetic sensor array , 2007 .

[7]  H. Grubin The physics of semiconductor devices , 1979, IEEE Journal of Quantum Electronics.

[8]  E Chirone,et al.  [The arterial pulse]. , 1970, Il Policlinico. Sezione pratica.

[9]  H. Harry Asada,et al.  Cuffless Blood Pressure Monitoring Using Hydrostatic Pressure Changes , 2008, IEEE Transactions on Biomedical Engineering.

[10]  Y C Fung,et al.  Neutral axis location in bending and Young's modulus of different layers of arterial wall. , 1993, The American journal of physiology.

[11]  Daniel Levy,et al.  Systolic Blood Pressure, Diastolic Blood Pressure, and Pulse Pressure as Predictors of Risk for Congestive Heart Failure in the Framingham Heart Study , 2003, Annals of Internal Medicine.

[12]  G. W. Kim,et al.  Achievement of 3-D Pulse Waves of Pulse Diagnostic Apparatus by using Multi-Hall Devices , 2006 .