Electrical properties of metallic electrodes

The series equivalent resistance R and capacitance C of metal/saline electrode/electrolyte interfaces were measured as a function of frequency (100 Hz–20k Hz) and current density (0·25 to 1000 A m−2) for eight typical electrode metals. For each of the metals tested, R decreased and C increased as the current density was increased above a critical value (with the exception of silver and MP35N at frequencies above 1 kHz for which R increased and C decreased slightly). With the exception of copper, the current density linearity limit (for 10 per cent decrease in R or 10 per cent increase in C) increased with increasing frequency and, in most cases, the current density linearity limit for 10 per cent increase in C was slightly less than that for 10 per cent decrease in R. Among the metals tested, copper and aluminium had the lowest current carrying capability and rhodium had the highest current-carrying capability. The current carrying capabilities of 316 SS, platinum, silver and MP35N, were intermediate and similar. With increasing current density, an increase in the electrode/electrolyte capacitance was the most sensitive indicator of the current-carrying linearity limit.

[1]  B. Onaral,et al.  Linear and nonlinear properties of platinum electrode polarisation. Part 1: frequency dependence at very low frequencies , 1982, Medical and Biological Engineering and Computing.

[2]  Anthony M. Dymond,et al.  Characteristics of the Metal-Tissue Interface of Stimulation Electrodes , 1976, IEEE Transactions on Biomedical Engineering.

[3]  Joseph G. Hoffman,et al.  Physical Techniques in Biological Research , 1963 .

[4]  Herman P. Schwan,et al.  CHAPTER 6 – DETERMINATION OF BIOLOGICAL IMPEDANCES1 , 1963 .

[5]  J. Weinman,et al.  An analysis of electrical properties of metal electrodes , 1964, Medical electronics and biological engineering.

[6]  D B Geselowitz,et al.  Nonlinearity of cardiac pacemaker electrodes. , 1969, IEEE transactions on bio-medical engineering.

[7]  L. Geddes Electrodes and the measurement of bioelectric events , 1972 .

[8]  E. Warburg,et al.  Ueber das Verhalten sogenannter unpolarisirbarer Elektroden gegen Wechselstrom , 1899 .

[9]  L. A. Geddes,et al.  The impedance of stainless-steel electrodes , 1971, Medical and biological engineering.

[10]  H. Fricke,et al.  XXXIII. The theory of electrolytic polarization , 1932 .

[11]  L. Geddes Measurement of Electrolytic Resistivity and Electrode-Electrolyte Impedance with a Variable-Length Conductivity Cell , 1972 .

[12]  Robert Kennedy L. Chemical analysis of an uncommon species of zeolite , 1803 .

[13]  H P Schwan,et al.  ELECTRODE POLARIZATION IMPEDANCE AND MEASUREMENTS IN BIOLOGICAL MATERIALS * , 1968, Annals of the New York Academy of Sciences.

[14]  J. D. Bourland,et al.  The Rectification Properties of an Electrode-Electrolyte Interface Operated at High Sinusoidal Current Density , 1987, IEEE Transactions on Biomedical Engineering.