Chapter 2 Tracking Devices

Tracking devices are an essential component of an image-guided surgery system. These devices are used to track the position of instruments relative to the patient anatomy. Although early tracking systems were essentially mechanical digitizers, the field quickly adopted optical tracking systems because of their high accuracy and relatively large workspace. However, optical tracking systems require that a line-of-sight be maintained between the tracking device and the instrument to be tracked, which is not always convenient and precludes tracking of flexible instruments inside the body. Therefore, electromagnetic tracking systems were developed that had no line-of-sight requirement and could track instruments such as catheters and the tips of needles inside the body. The choice of tracking system is highly application dependent and requires an understanding of the desired working volume and accuracy requirements. To meet these needs, a variety of tracking devices and techniques have been introduced as described in this chapter.

[1]  Andrew D. Wiles,et al.  Accuracy assessment protocols for elektromagnetic tracking systems , 2003, CARS.

[2]  C. Hovendal,et al.  A new method for three-dimensional laparoscopic ultrasound model reconstruction , 2004, Surgical Endoscopy And Other Interventional Techniques.

[3]  K P Wang,et al.  Three-dimensional CT-guided bronchoscopy with a real-time electromagnetic position sensor: a comparison of two image registration methods. , 2000, Chest.

[4]  Donald L King Errors as a result of metal in the near environment when using an electromagnetic locator with freehand three-dimensional echocardiography. , 2002, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[5]  K. Cleary,et al.  Electromagnetic tracking for abdominal interventions in computer aided surgery , 2006, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[6]  Patrick A Kupelian,et al.  Influence of intrafraction motion on margins for prostate radiotherapy. , 2006, International journal of radiation oncology, biology, physics.

[7]  M. Figl,et al.  Design and application of an assessment protocol for electromagnetic tracking systems. , 2005, Medical physics.

[8]  Stanley W. Shepperd,et al.  Quaternion from Rotation Matrix , 1978 .

[9]  T. Başar,et al.  A New Approach to Linear Filtering and Prediction Problems , 2001 .

[10]  Wolfgang Birkfellner,et al.  A fully automated calibration method for an optical see-through head-mounted operating microscope with variable zoom and focus , 2005, IEEE Transactions on Medical Imaging.

[11]  S. Ben‐Haim,et al.  Novel Magnetic Technology for Intraoperative Intracranial Frameless Navigation: In Vivo and in Vitro Results , 2001, Neurosurgery.

[12]  M S Eljamel,et al.  Accuracy, efficacy, and clinical applications of the Radionics Operating Arm System. , 1997, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[13]  S J Zinreich,et al.  In vivo accuracy testing and clinical experience with the ISG Viewing Wand. , 1996, Neurosurgery.

[14]  H. Reinhardt,et al.  CT-guided "real time" stereotaxy. , 1989, Acta neurochirurgica. Supplementum.

[15]  H Shirato,et al.  Use of an implanted marker and real-time tracking of the marker for the positioning of prostate and bladder cancers. , 2000, International journal of radiation oncology, biology, physics.

[16]  M. Tillich,et al.  Multislice CT-image-guided endoscopic sinus surgery using an electromagnetic tracking system , 2002, European Radiology.

[17]  Koichi Yamazaki,et al.  Real‐time tumor‐tracking radiation therapy for lung carcinoma by the aid of insertion of a gold marker using bronchofiberscopy , 2002, Cancer.

[18]  P Munger,et al.  Comparison of relative accuracy between a mechanical and an optical position tracker for image-guided neurosurgery. , 1995, Journal of image guided surgery.

[19]  John T. Wei,et al.  Target localization and real-time tracking using the Calypso 4D localization system in patients with localized prostate cancer. , 2006, International journal of radiation oncology, biology, physics.

[20]  J. Strohbehn,et al.  A frameless stereotaxic integration of computerized tomographic imaging and the operating microscope. , 1986, Journal of neurosurgery.

[21]  S. Horgan,et al.  A prospective analysis of 211 robotic-assisted surgical procedures , 2003, Surgical Endoscopy And Other Interventional Techniques.

[22]  Jay B. West,et al.  Implementation, calibration and accuracy testing of an image-enhanced endoscopy system , 2002, IEEE Transactions on Medical Imaging.

[23]  Suzanne LaScalza,et al.  Effect of metal and sampling rate on accuracy of Flock of Birds electromagnetic tracking system. , 2003, Journal of biomechanics.

[24]  Jun Sugiyama,et al.  Tracking of a bronchoscope using epipolar geometry analysis and intensity-based image registration of real and virtual endoscopic images , 2002, Medical Image Anal..

[25]  Wolfgang Birkfellner,et al.  Calibration of tracking systems in a surgical environment , 1998, IEEE Transactions on Medical Imaging.

[26]  P Hofman,et al.  Feasibility of automatic marker detection with an a-Si flat-panel imager. , 2001, Physics in medicine and biology.

[27]  Naoki Suzuki,et al.  Development of a new three-dimensional endoscopic ultrasound system through endoscope shape monitoring. , 2003, Studies in health technology and informatics.

[28]  D. R. Fish,et al.  A patient-to-computed-tomography image registration method based on digitally reconstructed radiographs. , 1994, Medical physics.

[29]  Terry M. Peters,et al.  A hardware and software protocol for the evaluation of electromagnetic tracker accuracy in the clinical environment: a multi-center study , 2007, SPIE Medical Imaging.

[30]  Rong Zhu,et al.  A real-time articulated human motion tracking using tri-axis inertial/magnetic sensors package , 2004, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[31]  Franz Kainberger,et al.  Quantitative analysis of factors affecting intraoperative precision and stability of optoelectronic and electromagnetic tracking systems. , 2002, Medical physics.

[32]  H Bergmann,et al.  Positioning of dental implants using computer-aided navigation and an optical tracking system: case report and presentation of a new method. , 1999, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[33]  K. Cleary,et al.  Navigation with electromagnetic tracking for interventional radiology procedures: a feasibility study. , 2005, Journal of vascular and interventional radiology : JVIR.

[34]  J Pouliot,et al.  Robustness and precision of an automatic marker detection algorithm for online prostate daily targeting using a standard V-EPID. , 2003, Medical physics.

[35]  H. Calkins,et al.  Real-Time Cardiac Catheter Navigation on Three-Dimensional CT Images , 2003, Journal of Interventional Cardiac Electrophysiology.

[36]  J. Mühling,et al.  Intraoperative navigation in oral and maxillofacial surgery. , 1995, International journal of oral and maxillofacial surgery.

[37]  H Bergmann,et al.  Systematic distortions in magnetic position digitizers. , 1998, Medical physics.

[38]  Richard J. Evans,et al.  Development and preliminary evaluation of VISLAN, a surgical planning and guidance system using intra-operative video imaging , 1996, Medical Image Anal..

[39]  D R Sandeman,et al.  The ISG viewing wand: an application to atlanto-axial cervical surgery using the Le Fort I maxillary osteotomy. , 1995, The British journal of oral & maxillofacial surgery.

[40]  Jürgen Weese,et al.  A comparison of similarity measures for use in 2-D-3-D medical image registration , 1998, IEEE Transactions on Medical Imaging.

[41]  D C Barratt,et al.  Accuracy of an electromagnetic three-dimensional ultrasound system for carotid artery imaging. , 2001, Ultrasound in medicine & biology.

[42]  Wolfgang Birkfellner,et al.  Wobbled splatting—a fast perspective volume rendering method for simulation of x-ray images from CT , 2005, Physics in medicine and biology.

[43]  D. H. Mellor,et al.  Real time , 1981 .

[44]  A Wagner,et al.  Augmented reality environment for temporomandibular joint motion analysis. , 1996, The International journal of adult orthodontics and orthognathic surgery.

[45]  D. R. Fish,et al.  Frameless stereotaxy and interactive neurosurgery with the ISG viewing wand. , 1995, Acta neurochirurgica. Supplement.

[46]  Ronald Azuma,et al.  Improving static and dynamic registration in an optical see-through HMD , 1994, SIGGRAPH.

[47]  S. Kirsh,et al.  Real time tracking of tumor positions for precision irradiation , 1998 .

[48]  Daniel M Aebersold,et al.  Daily organ tracking in intensity-modulated radiotherapy of prostate cancer using an electronic portal imaging device with a dose saving acquisition mode. , 2006, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[49]  Naoki Suzuki,et al.  A novel 3-dimensional EUS technique for real-time visualization of the volume data reconstruction process. , 2002, Gastrointestinal endoscopy.

[50]  Wolfgang Birkfellner,et al.  Evaluation of a miniature electromagnetic position tracker. , 2002, Medical physics.

[51]  Max A. Viergever,et al.  Guide Wire Tracking During Endovascular Interventions , 2000, MICCAI.

[52]  R Perez,et al.  Effect of optical digitizer selection on the application accuracy of a surgical localization system-a quantitative comparison between the OPTOTRAK and flashpoint tracking systems. , 1999, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[53]  J. Anon,et al.  Computer‐aided endoscopic sinus surgery , 1998, The Laryngoscope.

[54]  Hirokazu Kato,et al.  Marker tracking and HMD calibration for a video-based augmented reality conferencing system , 1999, Proceedings 2nd IEEE and ACM International Workshop on Augmented Reality (IWAR'99).

[55]  K. Takakura,et al.  Three-dimensional digitizer (neuronavigator): new equipment for computed tomography-guided stereotaxic surgery. , 1987, Surgical neurology.

[56]  Bostjan Likar,et al.  A protocol for evaluation of similarity measures for rigid registration , 2006, IEEE Transactions on Medical Imaging.

[57]  James A. Johnson,et al.  Accuracy of an electromagnetic tracking device: a study of the optimal range and metal interference. , 1996, Journal of biomechanics.

[58]  G. King,et al.  Accuracy of an electromagnetic tracking device: a study of the optimal range and metal interference. , 1996, Journal of biomechanics.

[59]  L. Joskowicz,et al.  Gradient-based 2-D/3-D rigid registration of fluoroscopic X-ray to CT , 2003, IEEE Transactions on Medical Imaging.

[60]  F. Langlotz,et al.  Clinical evaluation of a system for precision enhancement in spine surgery. , 1995, Clinical biomechanics.

[61]  F. V. D. van der Helm,et al.  Calibration of the "Flock of Birds" electromagnetic tracking device and its application in shoulder motion studies. , 1999, Journal of biomechanics.

[62]  Wolfgang Birkfellner,et al.  A head-mounted operating binocular for augmented reality visualization in medicine - design and initial evaluation , 2002, IEEE Transactions on Medical Imaging.

[63]  Li-Ming Su,et al.  Comparison of surgical performance during laparoscopic radical prostatectomy of two robotic camera holders, EndoAssist and AESOP: a pilot study. , 2006, Urology.

[64]  Theo van Walsum,et al.  Accuracy evaluation of direct navigation with an isocentric 3D rotational X-ray system , 2006, Medical Image Anal..

[65]  J A Rowlands,et al.  Imaging of 1.0-mm-diameter radiopaque markers with megavoltage X-rays: an improved online imaging system. , 2002, International journal of radiation oncology, biology, physics.

[66]  Daniel Rueckert,et al.  Fast generation of digitally reconstructed radiographs using attenuation fields with application to 2D-3D image registration , 2005, IEEE Transactions on Medical Imaging.

[67]  P. Kelly,et al.  A stereotactic magnetic field digitizer. , 1994, Stereotactic and functional neurosurgery.

[68]  Wolfgang Birkfellner,et al.  A faster method for 3D/2D medical image registration—a simulation study , 2003, Physics in medicine and biology.

[69]  Jay B. West,et al.  Predicting error in rigid-body point-based registration , 1998, IEEE Transactions on Medical Imaging.

[70]  R. K. Münch,et al.  A novel tracking technique for the continuous precise measurement of tumour positions in conformal radiotherapy. , 2000, Physics in medicine and biology.

[71]  M. Fried,et al.  Image‐Guided Endoscopic Surgery: Results of Accuracy and Performance in a Multicenter Clinical Study Using an Electromagnetic Tracking System , 1997, The Laryngoscope.

[72]  M. Donat,et al.  Stability of miniature electromagnetic tracking systems. , 2005, Physics in medicine and biology.

[73]  Huosheng Hu,et al.  Inertial measurements of upper limb motion , 2006, Medical and Biological Engineering and Computing.

[74]  K. Smith,et al.  The NeuroStation--a highly accurate, minimally invasive solution to frameless stereotactic neurosurgery. , 1994, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[75]  Logan W. Clements,et al.  Concepts and Preliminary Data Toward the Realization of Image-guided Liver Surgery , 2007, Journal of Gastrointestinal Surgery.

[76]  R. Kikinis,et al.  A new visualization technique for laparoscopic ultrasonography. , 2004, Surgery.

[77]  保罗·G·赛勒 Device for determining the position of body parts , 2000 .

[78]  T. Vogl,et al.  Navigation-Based Needle Puncture of a Cadaver Using a Hybrid Tracking Navigational System , 2006, Investigative radiology.

[79]  David J. Hawkes,et al.  Design and evaluation of a system for microscope-assisted guided interventions (MAGI) , 2000 .

[80]  Kawal S. Rhode,et al.  Intensity-based 2-D - 3-D registration of cerebral angiograms , 2003, IEEE Transactions on Medical Imaging.

[81]  O. Suess,et al.  Intracranial Image-Guided Neurosurgery: Experience with a new Electromagnetic Navigation System , 2001, Acta Neurochirurgica.

[82]  M. Figl,et al.  Evaluation of a new electromagnetic tracking system using a standardized assessment protocol , 2006, Physics in medicine and biology.

[83]  T. Vogl,et al.  Accuracy of biopsy needle navigation using the Medarpa system—computed tomography reality superimposed on the site of intervention , 2005, European Radiology.

[84]  Hans Blattmann,et al.  Combining magnetic and optical tracking for computer aided therapy. , 2004, Zeitschrift fur medizinische Physik.

[85]  David J. Hawkes,et al.  Design and evaluation of a system for microscope-assisted guided interventions (MAGI) , 1999, IEEE Transactions on Medical Imaging.

[86]  Zhaoying Zhou,et al.  A real-time articulated human motion tracking using tri-axis inertial/magnetic sensors package. , 2004, IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society.

[87]  S. Schmerber,et al.  Accuracy evaluation of a CAS system: laboratory protocol and results with 6D localizers, and clinical experiences in otorhinolaryngology. , 2001, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[88]  Ron Kikinis,et al.  Augmented reality visualization for CT-guided interventions: system description, feasibility, and initial evaluation in an abdominal phantom. , 2006, Radiology.

[89]  Daisuke Deguchi,et al.  A method for bronchoscope tracking by combining a position sensor and image registration. , 2005, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[90]  Michael A. King,et al.  Use of three-dimensional Gaussian interpolation in the projector/backprojector pair of iterative reconstruction for compensation of known rigid-body motion in SPECT , 2006, IEEE Transactions on Medical Imaging.

[91]  Holger Timinger,et al.  Modality-integrated magnetic catheter tracking for x-ray vascular interventions. , 2005, Physics in medicine and biology.

[92]  H. Feußner,et al.  Electromagnetic catheter navigation during bronchoscopy: validation of a novel method by conventional fluoroscopy. , 2005, Chest.

[93]  H. Meinzer,et al.  Effect of 3D ultrasound probes on the accuracy of electromagnetic tracking systems. , 2006, Ultrasound in medicine & biology.

[94]  Richard Pötter,et al.  Automatic real-time surveillance of eye position and gating for stereotactic radiotherapy of uveal melanoma. , 2004, Medical physics.

[95]  T Josefsson,et al.  A flexible high-precision video system for digital recording of motor acts through lightweight reflex markers. , 1996, Computer methods and programs in biomedicine.

[96]  K. Takakura,et al.  Development of a frameless and armless stereotactic neuronavigation system with ultrasonographic registration. , 1997, Neurosurgery.

[97]  H F Reinhardt,et al.  Interactive sonar-operated device for stereotactic and open surgery. , 1990, Stereotactic and functional neurosurgery.

[98]  Jack B. Kuipers SPASYN-an electromagnetic relative position and orientation tracking system , 1980, IEEE Transactions on Instrumentation and Measurement.

[99]  E P Wilkinson,et al.  Comparative tracking error analysis of five different optical tracking systems. , 2000, Computer aided surgery : official journal of the International Society for Computer Aided Surgery.

[100]  L. Gepstein,et al.  A novel method for nonfluoroscopic catheter-based electroanatomical mapping of the heart. In vitro and in vivo accuracy results. , 1997, Circulation.

[101]  A Wagner,et al.  Virtual image guided navigation in tumor surgery--technical innovation. , 1995, Journal of cranio-maxillo-facial surgery : official publication of the European Association for Cranio-Maxillo-Facial Surgery.

[102]  D R Sandeman,et al.  Intra-operative image guidance in otolaryngology--the use of the ISG viewing wand. , 1996, The Journal of laryngology and otology.

[103]  Y Watanabe,et al.  A system for nonradiographic source localization and real-time planning of intraoperative high dose rate brachytherapy. , 1997, Medical physics.

[104]  Vincent Schlageter,et al.  Noninvasive verification of nasogastric tube placement using a magnet-tracking system: a pilot study in healthy subjects. , 2005, JPEN. Journal of parenteral and enteral nutrition.

[105]  W. Thumfart,et al.  Image-guided endoscopic ENT surgery , 2007, European Archives of Oto-Rhino-Laryngology.

[106]  A R Javer,et al.  Stereotactic Computer-Assisted Navigational Sinus Surgery: Accuracy of an Electromagnetic Tracking System with the Tissue Debrider and when Utilizing Different Headsets for the Same Patient , 2000, American journal of rhinology.

[107]  L J van Ruijven,et al.  The accuracy of joint surface models constructed from data obtained with an electromagnetic tracking device. , 2000, Journal of biomechanics.

[108]  J.C.K. Chou,et al.  Quaternion kinematic and dynamic differential equations , 1992, IEEE Trans. Robotics Autom..

[109]  L Zamorano,et al.  Computer-assisted neurosurgery system: Wayne State University hardware and software configuration. , 1994, Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society.

[110]  T D Brown,et al.  Factors influencing accuracy of screw displacement axis detection with a D.C.-based electromagnetic tracking system. , 1998, Journal of biomechanical engineering.

[111]  François Poulin,et al.  Interference during the use of an electromagnetic tracking system under OR conditions. , 2002, Journal of biomechanics.

[112]  H. Coakham,et al.  Advances in image-directed neurosurgery: preliminary experience with the ISG Viewing Wand compared with the Leksell G frame. , 1994, British journal of neurosurgery.

[113]  F. Raab,et al.  Magnetic Position and Orientation Tracking System , 1979, IEEE Transactions on Aerospace and Electronic Systems.

[114]  Uwe Just,et al.  An accurate method for correction of head movement in PET , 2004, IEEE Transactions on Medical Imaging.

[115]  S. Nishioka,et al.  A computer-assisted operation for congenital aural malformations. , 1996, International journal of pediatric otorhinolaryngology.

[116]  C. Lumenta,et al.  BrainLab VectorVision Neuronavigation System: technology and clinical experiences in 131 cases. , 1999, Neurosurgery.