Development of advanced signal processing and source imaging methods for superparamagnetic relaxometry

Superparamagnetic relaxometry (SPMR) is a highly sensitive technique for the in vivo detection of tumor cells and may improve early stage detection of cancers. SPMR employs superparamagnetic iron oxide nanoparticles (SPION). After a brief magnetizing pulse is used to align the SPION, SPMR measures the time decay of SPION using super-conducting quantum interference device (SQUID) sensors. Substantial research has been carried out in developing the SQUID hardware and in improving the properties of the SPION. However, little research has been done in the pre-processing of sensor signals and post-processing source modeling in SPMR. In the present study, we illustrate new pre-processing tools that were developed to: (1) remove trials contaminated with artifacts, (2) evaluate and ensure that a single decay process associated with bounded SPION exists in the data, (3) automatically detect and correct flux jumps, and (4) accurately fit the sensor signals with different decay models. Furthermore, we developed an automated approach based on multi-start dipole imaging technique to obtain the locations and magnitudes of multiple magnetic sources, without initial guesses from the users. A regularization process was implemented to solve the ambiguity issue related to the SPMR source variables. A procedure based on reduced chi-square cost-function was introduced to objectively obtain the adequate number of dipoles that describe the data. The new pre-processing tools and multi-start source imaging approach have been successfully evaluated using phantom data. In conclusion, these tools and multi-start source modeling approach substantially enhance the accuracy and sensitivity in detecting and localizing sources from the SPMR signals. Furthermore, multi-start approach with regularization provided robust and accurate solutions for a poor SNR condition similar to the SPMR detection sensitivity in the order of 1000 cells. We believe such algorithms will help establishing the industrial standards for SPMR when applying the technique in pre-clinical and clinical settings.

[1]  Thomas T. Liu,et al.  MEG source imaging method using fast L1 minimum-norm and its applications to signals with brain noise and human resting-state source amplitude images , 2014, NeuroImage.

[2]  L. Trahms,et al.  Investigation of Brownian and Néel relaxation in magnetic fluids , 1999 .

[3]  Roland R. Lee,et al.  Temporal dynamics of ipsilateral and contralateral motor activity during voluntary finger movement , 2004, Human brain mapping.

[4]  Gregory A. Miller,et al.  A parietal–frontal network studied by somatosensory oddball MEG responses, and its cross-modal consistency , 2005, NeuroImage.

[5]  J. Sarvas Basic mathematical and electromagnetic concepts of the biomagnetic inverse problem. , 1987, Physics in medicine and biology.

[6]  E. Halgren,et al.  Spatiotemporal mapping of brain activity by integration of multiple imaging modalities , 2001, Current Opinion in Neurobiology.

[7]  D. Harrington,et al.  MEG response to median nerve stimulation correlates with recovery of sensory and motor function after stroke , 2004, Clinical Neurophysiology.

[8]  C. Aine,et al.  Multistart Algorithms for MEG Empirical Data Analysis Reliably Characterize Locations and Time Courses of Multiple Sources , 2000, NeuroImage.

[9]  Lutz Trahms,et al.  Magnetic nanoparticles for biomedical applications , 2015, Biomedizinische Technik. Biomedical engineering.

[10]  M Huang,et al.  Multi-start downhill simplex method for spatio-temporal source localization in magnetoencephalography. , 1998, Electroencephalography and clinical neurophysiology.

[11]  Todor Karaulanov,et al.  Magnetic relaxometry as applied to sensitive cancer detection and localization , 2015, Biomedizinische Technik. Biomedical engineering.

[12]  L. Néel Some theoretical aspects of rock-magnetism , 1955 .

[13]  S. Supek,et al.  Simulation studies of multiple dipole neuromagnetic source localization: model order and limits of source resolution , 1993, IEEE Transactions on Biomedical Engineering.

[14]  H. Bryant,et al.  A biomagnetic system for in vivo cancer imaging , 2005, Physics in medicine and biology.

[15]  E. Somersalo,et al.  Visualization of Magnetoencephalographic Data Using Minimum Current Estimates , 1999, NeuroImage.

[16]  J. Stephen,et al.  Sources on the anterior and posterior banks of the central sulcus identified from magnetic somatosensory evoked responses using Multi‐Start Spatio‐Temporal localization , 2000, Human brain mapping.

[17]  G. A. Miller,et al.  Predicting EEG responses using MEG sources in superior temporal gyrus reveals source asynchrony in patients with schizophrenia , 2003, Clinical Neurophysiology.

[18]  P. Maas,et al.  Fetal magnetocardiography: Methods for rapid data reduction , 1997 .

[19]  Anders M. Dale,et al.  Vector-based spatial–temporal minimum L1-norm solution for MEG , 2006, NeuroImage.

[20]  John Watt,et al.  Enhanced Nanoparticle Size Control by Extending LaMer’s Mechanism , 2015 .

[21]  R D Pascual-Marqui,et al.  Standardized low-resolution brain electromagnetic tomography (sLORETA): technical details. , 2002, Methods and findings in experimental and clinical pharmacology.

[22]  Lutz Trahms,et al.  Magnetorelaxometry procedures for quantitative imaging and characterization of magnetic nanoparticles in biomedical applications , 2015, Biomedizinische Technik. Biomedical engineering.

[23]  Kimberly S Butler,et al.  Imaging of Her2-targeted magnetic nanoparticles for breast cancer detection: comparison of SQUID-detected magnetic relaxometry and MRI. , 2012, Contrast media & molecular imaging.

[24]  Kimberly S Butler,et al.  Detection of breast cancer cells using targeted magnetic nanoparticles and ultra-sensitive magnetic field sensors , 2011, Breast Cancer Research.

[25]  Lutz Trahms,et al.  Quantification of drug-loaded magnetic nanoparticles in rabbit liver and tumor after in vivo administration , 2009 .

[26]  Martin Luessi,et al.  MNE software for processing MEG and EEG data , 2014, NeuroImage.

[27]  B. Tanner,et al.  Time-dependent magnetization in fine-particle ferromagnetic systems , 1983 .