Development of phantoms for spiral CT.

PURPOSE This paper reports on the development of a new phantom for spiral CT. The phantom meets the increased demands on phantom z-axis uniformity in order that objects from the CT slice, immediately above and below the CT slice of interest, do not contribute perturbing information to the reconstructed CT slice. MATERIAL AND METHODS The phantom depends on formulation of tissue-like materials that can be cast and produced in both geometric and anthropomorphic shapes with sufficient z-axis length to enable unperturbed CT slices of test objects of interest. These materials are then used to produce a series of test objects of CT image quality including low contrast samples that do not require volume averaging or mixing of solutions, and that can reflect sub-slice thickness test objects and supra-slice thickness test objects. RESULTS The overall phantom and its individual test objects provides meaningful tests of spiral CT image quality including slice sensitivity, CT number linearity and tests of high and low contrast resolution. Schematic designs and actual CT scans are shown. CONCLUSION The new spiral phantom appears to meet the increased demands of spiral CT on phantom design, particularly z-axis length, and requirements for low contrast resolution test objects.

[1]  R T Droege,et al.  An MTF method immune to aliasing. , 1985, Medical physics.

[2]  Kenneth E. Weaver,et al.  Development of a Phantom for Evaluation and Assurance Of Image Quality in CT Scanning , 1977 .

[3]  K F King,et al.  Computed tomography scanning with simultaneous patient translation. , 1990, Medical physics.

[4]  R. J. Kriz,et al.  An Investigation Of Computed Tomography (CT) Linearity , 1985, Medical Imaging.

[5]  M. E. Masterson,et al.  Epoxy-resin-based tissue substitutes. , 1977, Medical physics.

[6]  D. Goodenough,et al.  Volume averaging limitations of computed tomography. , 1981, AJR. American journal of roentgenology.

[7]  D J Goodenough,et al.  A new software correction approach to volume averaging artifacts in CT. , 1986, Computerized radiology : official journal of the Computerized Tomography Society.

[8]  D. Goodenough,et al.  Potential artifacts associated with the scanning pattern of the EMI scanner. , 1975, Radiology.

[9]  M. Vannier,et al.  Spiral (helical) CT. , 1993, Radiology.

[10]  D J Goodenough,et al.  Factors related to low contrast resolution in CT scanners. , 1984, Computerized radiology : official journal of the Computerized Tomography Society.

[11]  K. Rossmann Point spread-function, line spread-function, and modulation transfer function. Tools for the study of imaging systems. , 1969, Radiology.