Fracture of a Titanium Non-Modular Femoral Stem After Revision Total Hip Arthroplasty A Case Report and Review of the Literature.
暂无分享,去创建一个
BACKGROUND
Femoral stem fracture is a rare and morbid complication after total hip arthroplasty (THA). There currently exists a paucity of reports regarding cementless non-modular, titanium, femoral stem fractures.
METHODS
A case report and review of the literature for modular and non-modular stem fractures was conducted.
RESULTS
We report the first documented fatigue fracture in the Wagner Self-Locking (SL) Revision (Zimmer-Biomet, Warsaw, Indiana) System.
DISCUSSION
Proximal stress shielding can lead to poor bone support and contribute to excessive cantilever bending forces, even on non-modular, titanium, tapered stems. Body mass index, prosthetic diameter, and stem length are factors that need to be vetted in order to prevent this complication.