Guided ultrasonic waves in long bones: modelling, experiment and in vivo application.

Existing ultrasound devices for assessing the human tibia are based on detecting the first arriving signal, corresponding to a wave propagating at, or close to, the bulk longitudinal velocity in bone. However, human long bones are effectively irregular hollow tubes and should theoretically support the propagation of more complex guided modes similar to Lamb waves in plates. Guided waves are attractive because they propagate throughout the bone thickness and can potentially yield more information on bone material properties and architecture. In this study, Lamb wave theory and numerical simulations of wave propagation were used to gain insights into the expected behaviour of guided waves in bone. Experimental measurements in acrylic plates, using a prototype low-frequency axial pulse transmission device, confirmed the presence of two distinct propagating waves: the first arriving wave propagating at, or close to, the longitudinal velocity, and a slower second wave whose behaviour was consistent with the lowest order Lamb antisymmetrical (A0) mode. In a pilot study of healthy and osteoporotic subjects, the velocity of the second wave differed significantly between the two groups, whereas the first arriving wave velocity did not, suggesting the former to be a more sensitive indicator of osteoporosis. We conclude that guided wave measurements may offer an enhanced approach to the ultrasonic characterization of long bones.

[1]  M. Bouxsein,et al.  Tibial ultrasound velocity measured in situ predicts the material properties of tibial cortical bone. , 1997, Bone.

[2]  G Berger,et al.  Analysis of the axial transmission technique for the assessment of skeletal status. , 2000, The Journal of the Acoustical Society of America.

[3]  R. Lakes,et al.  Ultrasonic wave propagation and attenuation in wet bone. , 1986, Journal of biomedical engineering.

[4]  D. Chimenti Guided Waves in Plates and Their Use in Materials Characterization , 1997 .

[5]  D. E. Chimenti,et al.  Nondestructive evaluation of composite laminates by leaky Lamb waves , 1991 .

[6]  M. Popovtzer,et al.  Quantitative ultrasound of the tibia: a novel approach for assessment of bone status. , 1995, Bone.

[7]  R. S. Schechter,et al.  Real-Time Parallel Computation and Visualization of Ultrasonic Pulses in Solids , 1994, Science.

[8]  G. W. Hyatt,et al.  Ultrasonic study of normal and fractured bone. , 1975, Clinical orthopaedics and related research.

[9]  S. Cheng,et al.  Ultrasound Velocity and Cortical Bone Characteristics In Vivo , 2001, Osteoporosis International.

[10]  R. C. Murry,et al.  Measurement of mechanical properties of bone material in vitro by ultrasound reflection: Methodology and comparison with ultrasound transmission , 1991, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[11]  H Jansons,et al.  Constructional peculiarities of the human tibia defined by reference to ultrasound measurement data. , 1984, Biomaterials.

[12]  E. Bossy,et al.  Effect of bone cortical thickness on velocity measurements using ultrasonic axial transmission: a 2D simulation study. , 2002, The Journal of the Acoustical Society of America.

[13]  J. Cheeke,et al.  Loading effects on A0 Lamb-like waves in full and partially filled thin-walled tubes , 1999 .

[14]  H. Lamb On waves in an elastic plate , 1917 .

[15]  I. Siegel,et al.  The determination of fracture healing by measurement of sound velocity across the fracture site. , 1958, Surgery, gynecology & obstetrics.

[16]  Peter Cawley,et al.  Guided waves in fluid-filled pipes surrounded by different fluids , 2001 .

[17]  Yoseph Bar-Cohen,et al.  Inversion of leaky Lamb wave data by simplex algorithm , 1990 .

[18]  Yan Li,et al.  Influence of anisotropy on the dispersion characteristics of guided ultrasonic plate modes , 1990 .

[19]  G Van der Perre,et al.  The effect of fracture and fracture fixation on ultrasonic velocity and attenuation. , 1996, Physiological measurement.

[20]  G Van der Perre,et al.  Ultrasound velocity measurement in long bones: measurement method and simulation of ultrasound wave propagation. , 1996, Journal of biomechanics.

[21]  H K Genant,et al.  An in vitro investigation of the dependence on sample thickness of the speed of sound along the specimen. , 1999, Medical engineering & physics.

[22]  G. Pharr,et al.  Microstructural elasticity and regional heterogeneity in human femoral bone of various ages examined by nano-indentation. , 2002, Journal of biomechanics.

[23]  Novikov Ve,et al.  [Osteoporosis in monkeys after anti-orthostatic hypokinesia]. , 1990 .

[24]  D. Hans,et al.  Quantitative Ultrasound of the Tibia Depends on Both Cortical Density and Thickness , 2001, Osteoporosis International.

[25]  G Lowet,et al.  In vivo assessment of bone mechanical properties by vibration and ultrasonic wave propagation analysis. , 1996, Bone.

[26]  I. A. Viktorov Rayleigh and Lamb Waves , 1967 .

[27]  A. Goodship,et al.  Investigation of bone changes in microgravity during long and short duration space flight: comparison of techniques , 2000, European journal of clinical investigation.

[28]  Vinay Dayal,et al.  Leaky Lamb waves in an anisotropic plate. I: An exact solution and experiments , 1989 .

[29]  M. Bouxsein,et al.  Prediction of the strength of the elderly proximal femur by bone mineral density and quantitative ultrasound measurements of the heel and tibia. , 1999, Bone.

[30]  M. Castaings,et al.  Lamb and SH waves generated and detected by air-coupled ultrasonic transducers in composite material plates , 2001 .