Non-expert use of quantitative EEG displays for seizure identification in the adult neuro-intensive care unit

Video-EEG monitoring is the ultimate way to diagnose non-convulsive status epilepticus (NCSE) in intensive care units (ICU). Usually EEG recordings are evaluated once a day by an electrophysiologist, which may lead to delay in diagnosis. Digital EEG trend analysis methods like amplitude integrated EEG (aEEG) and density spectral array (DSA) have been developed to facilitate recognition of seizures. In this study, we aimed to investigate the diagnostic utility of these methods by non-expert physicians and ICU nurses for NCSE identification in an adult neurological ICU. Ten patients with NCSE and ten control patients without seizures were included in the study. The raw EEG recordings of all subjects were converted to both aEEG and DSA and displayed simultaneously without conventional EEG. After training for seizure recognition with both methods, two physicians and two nurses analyzed the visual displays individually, and marked seizure timings. Their results were compared with those of a study epileptologist. Participants analyzed 615h of EEG data with 700 seizures. Overall, 63% of the seizures were recognized by all, 15.6% by three, 11.6% by two, 8.3% by one rater and only 1.5% were missed by all of them (sensitivity was 88-99%, and specificity was 89-95% when the ratings were assessed as 1-h epochs). False positive rates were 1 per 2h in the study and 1 per 6h in the control groups. Interrater agreement was high (κ=0.79-0.81). Bilateral independent seizures and ictal recordings with lower amplitude and shorter duration were more likely to be missed. There was no difference in performance between the rating of physicians and nurses. Our study demonstrates that bedside nurses, ICU fellows and residents can achieve acceptable level of accuracy for seizure identification using the digital EEG trend analysis methods following brief training. This may help earlier notification of the electrophysiologist who is not always available in ICUs.

[1]  Kenneth G. Jordan,et al.  An assessment of nonconvulsive seizures in the intensive care unit using continuous EEG monitoring , 1996, Neurology.

[2]  M Salinsky,et al.  Representation of sleep stages by color density spectral array. , 1987, Electroencephalography and clinical neurophysiology.

[3]  L Strunin,et al.  Monitoring Cerebral Function: Clinical Experience with New Device for Continuous Recording of Electrical Activity of Brain , 1971, British medical journal.

[4]  Tammy N Tsuchida,et al.  Amplitude-integrated electroencephalography in neonates. , 2009, Pediatric neurology.

[5]  S. Cash,et al.  Dietary protein and stroke prevention , 2014, Neurology.

[6]  G B Boylan,et al.  Non-expert use of the cerebral function monitor for neonatal seizure detection , 2004, Archives of disease in childhood. Fetal and neonatal edition.

[7]  L. Hirsch,et al.  Nonconvulsive seizures: Developing a rational approach to the diagnosis and management in the critically ill population , 2007, Clinical Neurophysiology.

[8]  C. Schevon,et al.  Cyclic electrographic seizures in critically ill patients , 2008, Epilepsia.

[9]  J. Claassen,et al.  Continuous EEG monitoring: is it ready for prime time? , 2009, Current opinion in critical care.

[10]  Joshua R. Smith,et al.  Prevalence of nonconvulsive status epilepticus in comatose patients , 2000, Neurology.

[11]  F. Torres,et al.  Continuous electrophysiologic monitoring of cerebral function in the pediatric intensive care unit. , 1988, Pediatric neurology.

[12]  R. Engelhardt,et al.  Single-channel amplitude integrated EEG recording for the identification of epileptic seizures by nonexpert physicians in the adult acute care setting , 2011, Journal of Clinical Monitoring and Computing.

[13]  L. Hirsch,et al.  Which EEG Patterns Warrant Treatment in the Critically Ill? Reviewing the Evidence for Treatment of Periodic Epileptiform Discharges and Related Patterns , 2005, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[14]  Vesna Micic,et al.  Seizure detection using digital trend analysis: Factors affecting utility , 2011, Epilepsy Research.

[15]  Linda S de Vries,et al.  Comparison between simultaneously recorded amplitude integrated electroencephalogram (cerebral function monitor) and standard electroencephalogram in neonates. , 2002, Pediatrics.

[16]  Dennis Dlugos,et al.  Neonatal seizure detection using multichannel display of envelope trend , 2008, Epilepsia.

[17]  Scott B. Wilson,et al.  Data Analysis for Continuous EEG Monitoring in the ICU: Seeing the Forest and the Trees , 2004, Journal of clinical neurophysiology : official publication of the American Electroencephalographic Society.

[18]  H. Otsubo,et al.  Seizure identification in the ICU using quantitative EEG displays , 2010, Neurology.

[19]  M. C. Rogers,et al.  Monitoring cerebral electrical function in the ICU. , 1980, Critical care medicine.

[20]  M Brandon Westover,et al.  Sensitivity of Compressed Spectral Arrays for Detecting Seizures in Acutely Ill Adults , 2014, Neurocritical Care.

[21]  Robert R. Clancy,et al.  Sensitivity of Amplitude-Integrated Electroencephalography for Neonatal Seizure Detection , 2007, Pediatrics.

[22]  Terrie E. Inder,et al.  Accuracy of Bedside Electroencephalographic Monitoring in Comparison With Simultaneous Continuous Conventional Electroencephalography for Seizure Detection in Term Infants , 2008, Pediatrics.

[23]  M. Toet,et al.  Brain monitoring in neonates. , 2009, Early human development.