Optimized readout of small gamma cameras for high resolution single gamma and positron emission imaging

Using a novel resistive readout scheme and off-the-shelf PCI ADC data acquisition cards, a compact readout and control system for mini gamma cameras based on position sensitive photomultiplier tubes (PMTs) has been developed. This economical resistive readout incorporates a special fractional subtraction technique to greatly expand the useful field of view of the PMTs to the very edges of their active area as compared to standard resistive readout methods such as charge division or Anger logic. This allows one to obtain the same quality images as those obtained with much more expensive and bulky individual wire readout data acquisition systems. The four output signals from the readout circuit can be digitized by a PCI ADC card in a computer to achieve high counting rates. Results will be shown for this readout applied to a dual modality breast biopsy system currently undergoing clinical trials and an ultra high resolution single gamma small animal imaging system for studies on mice and rats.

[1]  A. G. Weisenberger,et al.  High spatial resolution gamma imaging detector based on a 5" diameter R3292 Hamamatsu PSPMT , 1997 .

[2]  I. Mena,et al.  Prone scintimammography in patients with suspicion of carcinoma of the breast. , 1994, Journal of the American College of Surgeons.

[3]  L. Liberman,et al.  Calcification retrieval at stereotactic, 11-gauge, directional, vacuum-assisted breast biopsy. , 1998, Radiology.

[4]  I. Mena,et al.  Scintimammography: the complementary role of Tc-99m sestamibi prone breast imaging for the diagnosis of breast carcinoma. , 1995, Radiology.

[5]  Koon-Pong Wong,et al.  An investigation of coded aperture imaging for small animal SPECT , 2000 .

[6]  R. Wojcik,et al.  A combined scintimammography/stereotactic core biopsy digital X-ray system , 2000, 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149).

[7]  Randy Wojcik,et al.  Analog readout system with charge division type output , 2001, 2001 IEEE Nuclear Science Symposium Conference Record (Cat. No.01CH37310).

[8]  T. Lewellen,et al.  cMiCE: a high resolution animal PET using continuous LSO with a statistics based positioning scheme☆ , 2002 .

[9]  Simon R. Cherry,et al.  Simple charge division readouts for imaging scintillator arrays using a multi-channel PMT , 1995 .

[10]  Francesco Scopinaro,et al.  Multi-PSPMT scintillating camera , 1997 .

[11]  Christopher J. Thompson,et al.  A Simple Technique to Increase the Linearity and Field-of-View in Position Sensitive Photomultiplier Tubes , 1996 .

[12]  Simon R. Cherry,et al.  Optical fiber readout of scintillator arrays using a multi-channel PMT: a high resolution PET detector for animal imaging , 1995 .

[13]  Christopher J. Thompson,et al.  Positron emission mammography (PEM): a promising technique for detecting breast cancer , 1995 .