Averaging techniques for OCT imaging.

State-of-the-art Fourier-domain optical coherence tomography (OCT) allows for the acquisition of up to millions of spectral fringes per second. This large amount of data can be used to improve the quality of structural tomograms after effective averaging. Here, we compare three OCT image improvement techniques: magnitude averaging, complex averaging, and spectral and time domain OCT (STdOCT). We evaluate the performance for images on both linear and logarithmic intensity scales and discuss their advantages and disadvantages. We propose the use of the STdOCT approach as it offers the best advantages. Applications to in vivo imaging and speckle reduction are presented.

[1]  Anna Szkulmowska,et al.  Flow velocity estimation by complex ambiguity free joint Spectral and Time domain Optical Coherence Tomography. , 2009, Optics express.

[2]  Kelsey M. Kennedy,et al.  Improved measurement of vibration amplitude in dynamic optical coherence elastography , 2012, Biomedical optics express.

[3]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991 .

[4]  Maciej Wojtkowski,et al.  Coherent noise-free ophthalmic imaging by spectral optical coherence tomography , 2005 .

[5]  Iwona Gorczynska,et al.  Four-dimensional structural and Doppler optical coherence tomography imaging on graphics processing units , 2012, Journal of biomedical optics.

[6]  Robert J Zawadzki,et al.  Ultrahigh-resolution optical coherence tomography with monochromatic and chromatic aberration correction. , 2008, Optics express.

[7]  Maciej Wojtkowski,et al.  High-speed optical coherence tomography: basics and applications. , 2010, Applied optics.

[8]  J. Fujimoto,et al.  Ultrahigh speed spectral / Fourier domain OCT ophthalmic imaging at 70,000 to 312,500 axial scans per second. , 2008, Optics express.

[9]  Wolfgang Wieser,et al.  Multi-megahertz OCT: High quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second. , 2010, Optics express.

[10]  Iwona Gorczynska,et al.  Multi-parametric imaging of murine brain using spectral and time domain optical coherence tomography , 2012, Journal of biomedical optics.

[11]  Ruikang K. Wang,et al.  Digital phase stabilization to improve detection sensitivity for optical coherence tomography , 2007 .

[12]  M. Wojtkowski,et al.  Flow velocity estimation using joint Spectral and Time domain Optical Coherence Tomography. , 2008, Optics express.

[13]  A. Fercher,et al.  Performance of fourier domain vs. time domain optical coherence tomography. , 2003, Optics express.

[14]  M. Wojtkowski,et al.  Three-dimensional quantitative imaging of retinal and choroidal blood flow velocity using joint Spectral and Time domain Optical Coherence Tomography. , 2009, Optics express.

[15]  Edmund Koch,et al.  Enhanced joint spectral and time domain optical coherence tomography for quantitative flow velocity measurement , 2011, European Conference on Biomedical Optics.

[16]  Piotr Targowski,et al.  Structural examination of easel paintings with optical coherence tomography. , 2010, Accounts of chemical research.

[17]  Maciej Wojtkowski,et al.  Efficient Reduction of Speckle Noise in Optical Coherence Tomography References and Links , 2022 .

[18]  A. Fercher,et al.  Measurement of intraocular distances by backscattering spectral interferometry , 1995 .

[19]  Wolfgang Wieser,et al.  Multi-MHz FDML OCT: snapshot retinal imaging at 6.7 million axial-scans per second , 2012, Photonics West - Biomedical Optics.