Quantification of myocardial perfusion and determination of coronary stenosis severity during hyperemia using real-time myocardial contrast echocardiography.

Although regional myocardial perfusion can be currently quantified with myocardial contrast echocardiography (MCE) by using intermittent harmonic imaging (IHI), the method is tedious and time-consuming in the clinical setting. We hypothesized that regional myocardial perfusion can be quantified and the severity of coronary stenosis determined during hyperemia with MCE using real-time imaging (RTI) where microbubbles are not destroyed. Six open-chest dogs were studied during maximal hyperemia induced by adenosine in the absence or presence of coronary stenoses varying from mild to severe. Myocardial blood flow (MBF) was measured at each stage by using radiolabeled microspheres. MCE was performed using both IHI and RTI. Data for the latter were acquired in both end-systole and end-diastole. No differences were found between myocardial flow velocity (MFV) derived from IHI and RTI when end-systolic frames were used for the latter. MFV was consistently higher for RTI (P <.01) when end-diastolic frames were used. A linear relation was noted between MFV and radiolabeled microsphere-derived MBF ratios from the stenosed and the normal beds when end-systolic frames were used for RTI (r = 0.78, P <.001), whereas no relation was found when end-diastolic frames were used (r = 0.08, P =.78). The scatter for assessing MBF (A.beta) was minimal for IHI and RTI (9%-10%) with end-systolic frames, whereas that for RTI with end-diastolic frames was large (30%). Furthermore the correlation with radiolabeled microsphere-derived MBF was significantly (P <.01) weaker with RTI when end-diastolic frames were used (r = 0.53) than when end-systolic frames (r = 0.94) or IHI was used (r = 0.99). Data acquisition for IHI was 10 minutes, whereas it was 8 seconds for RTI. Thus, RTI can be used to quantify regional myocardial perfusion and stenosis severity during MCE. Only end-systolic frames, however, provide accurate data. RTI offers a rapid and easy means of assessing regional myocardial perfusion with MCE.

[1]  J I Hoffman,et al.  Blood flow measurements with radionuclide-labeled particles. , 1977, Progress in cardiovascular diseases.

[2]  R Krams,et al.  Coronary oscillatory flow amplitude is more affected by perfusion pressure than ventricular pressure. , 1990, The American journal of physiology.

[3]  F. Kajiya,et al.  Phasic characteristics of arterial inflow and venous outflow of right ventricular myocardium in dogs. , 1992, The American journal of physiology.

[4]  A R Jayaweera,et al.  Quantification of myocardial blood flow with ultrasound-induced destruction of microbubbles administered as a constant venous infusion. , 1998, Circulation.

[5]  S. Kaul,et al.  Detection of Noncritical Coronary Stenosis at Rest Without Recourse to Exercise or Pharmacological Stress , 2002, Circulation.

[6]  P. Dayton,et al.  Simultaneous optical and acoustical observations of contrast agents , 1997, 1997 IEEE Ultrasonics Symposium Proceedings. An International Symposium (Cat. No.97CH36118).

[7]  A R Jayaweera,et al.  Assessment of transmural distribution of myocardial perfusion with contrast echocardiography. , 1998, Circulation.

[8]  J Sklenar,et al.  Potential advantage of flash echocardiography for digital subtraction of B-mode images acquired during myocardial contrast echocardiography. , 1999, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[9]  S. Kaul,et al.  Role of capillaries in determining CBF reserve: new insights using myocardial contrast echocardiography. , 1999, The American journal of physiology.

[10]  A R Jayaweera,et al.  Basis for detection of stenosis using venous administration of microbubbles during myocardial contrast echocardiography: bolus or continuous infusion? , 1998, Journal of the American College of Cardiology.

[11]  B. Lüderitz,et al.  Real‐Time Contrast Echo Assessment of Myocardial Perfusion at Low Emission Power , 1999, Echocardiography.

[12]  T C Skalak,et al.  Direct In Vivo Visualization of Intravascular Destruction of Microbubbles by Ultrasound and Its Local Effects on Tissue. , 1998, Circulation.

[13]  G S Kassab,et al.  Morphometry of pig coronary venous system. , 1994, The American journal of physiology.