Cuffless and non-invasive Systolic Blood Pressure estimation for aged class by using a Photoplethysmograph

This study provides cuffless and non-invasive technique of Systolic Blood Pressure (SBP) estimation by using only a Photoplethysmography (PPG) sensor. As people get older, cardiovascular peculiarities are changing more and more, so this study focuses on the presumption of SBP in old age. Ages 60 and over were defined as old age and grouped into an aged class in this study, ages fewer than 60 were grouped into a young-middle class. The measured data in this experiment were both Capacity Pulse Wave (PW) and SBP. PW was obtained by the PPG and SBP was obtained by the commercial Blood Pressure (BP) meter with a cuff. Then the regression equation of SBP was calculated from individual information and features of PW. 96 healthy volunteers participated in the BP and PW measurement experiment. This result implied that patients' cardiovascular peculiarities change according to aging and vary among difference individuals. Furthermore, the data of old age were classified into four classes through a boundary values that depend on b and d of Acceleration Pulse Wave (APW). As regards the result of the aged class, the measured SBP was significantly correlated with the presumed SBP (r=0.89, SD=8.2mmHg) and the SD was 5.5 mmHg better than the SD of non-classified data. In conclusion, it is quite important for SBP estimation to divide data into several classes by age. Besides, the classification by using the parameters with the features of APW as individual cardiovascular peculiarities is a hopeful technique for the aged class. Therefore, the proposed techniques are quite promising and useful for the feature studies on cuffless and continuous BP monitoring.

[1]  Y. T. Zhang,et al.  Noninvasive and cuffless measurements of blood pressure for telemedicine , 2001, 2001 Conference Proceedings of the 23rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[2]  H. Imano,et al.  Evaluation of peripheral circulation with accelerated plethysmography and its practical application , 1986 .

[3]  T. Togawa,et al.  Continuous estimation of systolic blood pressure using the pulse arrival time and intermittent calibration , 2000, Medical and Biological Engineering and Computing.

[4]  Heejung Kang,et al.  Cuffless and Noninvasive Tonometry Mean Arterial Pressure Measurement by Physiological Characteristics and Applied Pressure , 2006, 2006 International Conference of the IEEE Engineering in Medicine and Biology Society.

[5]  Carmen C. Y. Poon,et al.  Modeling of Pulse Transit Time under the Effects of Hydrostatic Pressure for Cuffless Blood Pressure Measurements , 2006, 2006 3rd IEEE/EMBS International Summer School on Medical Devices and Biosensors.