Vascular Access Monitoring: Methods and Procedures – Something to Standardize?

The article discusses the issue of suitable parameters (pressures, recirculation and access flow) to assess hemodialysis vascular access quality (VAQ), available methods to measure those parameters and the setup of the entire VAQ surveillance system (VAQS) in a dialysis facility. Special attention is paid to factors which need some standardization to enable evaluation of VAQ trends in an individual as well as comparison of data from different patients and different dialysis facilities. The discussed procedures are documented with the authors’ own measurement results and the results of the VAQS implemented in their unit. Both dynamic and static pressures exhibit insufficient sensitivity in detecting stenoses in native arteriovenous fistulas. Access recirculation is a late finding because with its non-zero value dialysis quality is already compromised. Timely and reliable detection of a deteriorating access condition is enabled by access flow (QVA) only. No standardization is needed in extracorporeal blood flow used in QVA evaluation by ultrasonic dilution. Multiple measurements may increase the reliability of thermodilutional measurements and are a must in optodilutional ones. Timing of the measurement during dialysis should be standardized. Measurement frequency should take into account access type, QVA value and access history. Shortened intervals are needed in the immediate post-intervention period with regard to risk of re-stenosis incidence and strongly nonlinear QVA decreases in such cases. A significant shift-over from surgical interventions to balloon angioplasties is to be expected with the introduction of a VAQS, and appropriate measures must be taken to ensure their quick availability.

[1]  F. Lopot,et al.  Comparison of Different Techniques of Hemodialysis Vascular Access Flow Evaluation , 2003, The journal of vascular access.

[2]  L. Bednárová,et al.  Vascular access quality monitoring. , 2003, EDTNA-ERCA Journal.

[3]  F. Grandi,et al.  Acetate free hemodialysis Feasibility and comparison with acetate free biofiltration and bicarbonate dialysis , 2002 .

[4]  A. Besarab Preventing Vascular Access Dysfunction: Which Policy to Follow , 2002, Blood Purification.

[5]  J. Rubin,et al.  Analysis of variable flow Doppler hemodialysis access flow measurements and comparison with ultrasound dilution. , 2001, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[6]  J. Leypoldt,et al.  Noninvasive transcutaneous determination of access blood flow rate. , 2001, Kidney international.

[7]  F. Lopot,et al.  Vascular access monitoring evaluated from automated recirculation measurement. , 2001, EDTNA/ERCA journal.

[8]  B. Béné,et al.  Determination of access blood flow from ionic dialysance: theory and validation. , 1999, Kidney international.

[9]  F. Gotch,et al.  Measurement of blood access flow rate during hemodialysis from conductivity dialysance. , 1999, ASAIO journal.

[10]  V. Wizemann,et al.  Dynamic pressure measurement for detection of blood access stenosis. , 1998, EDTNA-ERCA Journal.

[11]  N M Krivitski,et al.  Novel method to measure access flow during hemodialysis by ultrasound velocity dilution technique. , 1995, ASAIO journal.

[12]  M. Moritz,et al.  Utility of intra-access pressure monitoring in detecting and correcting venous outlet stenoses prior to thrombosis. , 1995, Kidney international.

[13]  J T Daugirdas,et al.  Cardiopulmonary recirculation during hemodialysis. , 1992, Kidney international.

[14]  S. Schwab,et al.  Vascular access: concepts for the 1990s. , 1992, Journal of the American Society of Nephrology : JASN.

[15]  J. Klinowski,et al.  Aluminosilicate-lnduced Free Radical Generation by Murine Brain Glial Cells in vitro: Potential Significance in the Aetiopathogenesis of Alzheimer's Dementia , 1992 .

[16]  J. R. Raymond,et al.  Prevention of hemodialysis fistula thrombosis. Early detection of venous stenoses. , 1989, Kidney international.

[17]  R. Greenwood,et al.  The assessment of arteriovenous fistulae created for haemodialysis from pressure and thermal dilution measurements. , 1984, Journal of medical engineering & technology.

[18]  Clinical practice guidelines for vascular access. , 2006, American journal of kidney diseases : the official journal of the National Kidney Foundation.

[19]  P. Verdonck,et al.  Impact of dialyzer flow and surface area on whole-body and dialyzer clearance of middle molecules , 2004 .

[20]  G. Beathard Improving dialysis vascular access , 2002 .

[21]  E. Friedman,et al.  Correlates of vascular access and nonvascular access-related hospitalizations in hemodialysis patients. , 1996, American journal of nephrology.