Experimental characterisation and technical feasibility of a closed two-phase vs a conventional solar water heating thermosyphon

Abstract The present paper deals with Domestic Solar Water Heating Systems (DSWHS) for sanitary purposes. A Phase Change System (PCS) was designed and built. The PCS consists of a solar collector – thermo tank set that use a working fluid to indirectly transfer heat to the water. In some regions of Mexico, the high concentrations of minerals in the water accumulate to obstruct the pipes, preventing the solar collector from working. Using a suitable working fluid (different from water) avoids this problem, as well as freezing, corrosion, fouling and scaling, usually presented in conventional DSWHS. A conventional DSWHS with the same dimensions and geometry than the PCS was installed to compare their performance in simultaneous tests. Tests in the PCS were performed using three working fluids: R134a, R410A and acetone, under the actual field conditions of Temixco, Mexico. The technical feasibility of the three working fluids was investigated. Experimental data indicate that the PCS, loaded with either R134a or R410A, has equivalent performance than the DSWHS. However, high pressures and some difficulties to load the working fluid have to be dealt with. Lower performance was shown using acetone, but with the advantages of an easy load and low working pressure.

[1]  O. García-Valladares,et al.  Outdoor test method to determine the thermal behavior of solar domestic water heating systems , 2008 .

[2]  R. S. Soin,et al.  Performance of flat plate solar collector with fluid undergoing phase chance , 1979 .

[3]  K. S. Ong,et al.  Performance of a R-134a-filled thermosyphon , 2003 .

[4]  Jane H. Davidson,et al.  Design Optimization of a Two-Phase Solar Water Heater Using R-123 , 1992 .

[5]  Jane H. Davidson,et al.  Experimental Study of a Self-Pumping Boiling Collector Solar Hot Water System , 1988 .

[6]  M. McLinden,et al.  NIST Standard Reference Database 23: Reference Fluid Thermodynamic and Transport Properties-REFPROP, Version 8.0 , 2007 .

[7]  Sushil K. Chaturvedi,et al.  Thermodynamic analysis of two-component, two-phase flow in solar collectors with application to a direct-expansion solar-assisted heat pump , 1999 .

[8]  A. Kürklü,et al.  Thermal performance of a water-phase change material solar collector , 2002 .

[9]  Mehmet Esen,et al.  Experimental investigation of a two-phase closed thermosyphon solar water heater , 2005 .

[10]  Nathalie Mazet,et al.  An experimental and theoretical investigation of the transient behavior of a two-phase closed thermosyphon , 2003 .

[11]  H.M.S. Hussein,et al.  Transient investigation of a two phase closed thermosyphon flat plate solar water heater , 2002 .

[12]  J. M. Schreyer,et al.  Residential application of refrigerant-charged solar collectors , 1981 .

[13]  Jane H. Davidson,et al.  Second-Law Analysis of a Two-Phase Self-Pumping Solar Water Heater , 1992 .

[14]  Jorge Andaverde,et al.  Application of the error propagation theory in estimates of static formation temperatures in geothermal and petroleum boreholes , 2006 .

[15]  Rahmatollah Khodabandeh,et al.  Thermal performance of a closed advanced two-phase thermosyphon loop for cooling of radio base stations at different operating conditions , 2004 .

[16]  Jane H. Davidson,et al.  Analysis and simulation of a two-phase self-pumping water heater , 1990 .

[17]  Soteris A. Kalogirou,et al.  Environmental benefits of domestic solar energy systems , 2004 .

[18]  Ignacio Pichardo Pagaza Secretaría de Energía , 1995 .

[19]  J. M. Calm,et al.  Trade-offs in refrigerant selections: past, present, and future , 1998 .

[20]  H.M.S. Hussein,et al.  Transient investigation of a thermosyphon flat-plate solar collector , 1999 .