A method for measuring the CO2 dead space volume in facial visors and respiratory protective devices in human subjects.

The external CO2 dead space volume (Vd) in facial visors and respiratory protective devices is difficult, but important, to measure in human subjects. The lack of proper methods for its assessment has hampered the development of standards and the improvement of visor and device design. We have improved and evaluated a method for measuring Vd and the mean inspired fraction of CO2 (FI,CO2) in human subjects wearing facial visors or respiratory protective devices. The method is based on indirect measurements of inspiratory volumes using a calibrated respiratory inductive plethysmograph (RIP), and measurements of FCO2 with a mass spectrometer. The accuracy of the RIP method was assessed in eight subjects and its repeatability was studied during nasal and oral breathing, at rest and after bicycle ergometer work. We related the Vd,RIP results to two known external VdS (with the effective Vd equal to the geometric volume; 15 ml and 320 ml), through which the subjects breathed, using RIP and a pneumotachometer (PTM) simultaneously (Vd,RIP and Vd,PTM). The repeatability of Vd and mean FI,CO2 results was determined from duplicate recordings during the wearing of a welding visor. Initial RIP calibration was accepted if the inspiratory tidal volume error was < or = 10%. This resulted in an acceptable Vd,RIP error (< or = 20%; Vd = 320 ml) in six eight subjects. The validation technique allowed us to separate the Vd,RIP error into a volumetric error and an error related to CO2 measurement. Poor RIP volumetric accuracy over the initial portion of inspiration was detrimental to Vd accuracy. Using the welding visor, Vd and mean FI,CO2 were less at rest than after work and less during nasal breathing than during oral breathing. The intra-individual variability of Vd and mean FI,CO2 were lower during nasal breathing than during oral breathing. To summarize, the improved RIP based method can accurately (< or = 20% error) assess Vd and mean FI,CO2 in facial visors and respiratory protective devices in standardized work situations. A meticulous RIP calibration procedure and repeated validations of RIP volume and CO2 measurement accuracy must, however, be applied.

[1]  M. Sackner,et al.  Validation of respiratory inductive plethysmography using different calibration procedures. , 2015, The American review of respiratory disease.

[2]  N. Jones,et al.  The effect of added dead space on the pulmonary response to exercise. , 1971, Respiration; international review of thoracic diseases.

[3]  M. Sackner,et al.  Effects of breathing through external dead space on ventilation at rest and during exercise. II. , 1980, The American review of respiratory disease.

[4]  J. Schulte SEALED ENVIRONMENTS IN RELATION TO HEALTH AND DISEASE. , 1964, Archives of environmental health.

[5]  C. Poon Potentiation of exercise ventilatory response by airway CO2 and dead space loading. , 1992, Journal of applied physiology.

[6]  N. Anthonisen,et al.  Single-position calibration of the respiratory inductance plethysmograph. , 1983, Journal of applied physiology: respiratory, environmental and exercise physiology.

[7]  J. Kollias,et al.  Effect of respiratory valve dead space on pulmonary ventilation at rest and during exercise. , 1972, Medicine and Science in Sports.

[8]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[9]  G Wolff,et al.  Accurate measurement of N2 volumes during N2 washout requires dynamic adjustment of delay time. , 1985, Journal of applied physiology.

[10]  B. E. Welch,et al.  Effect of inspired PCO2 up to 30 mm Hg on response of normal man to exercise. , 1970, Journal of applied physiology.

[11]  W. A. Dale,et al.  Dead-space rebreathing tube for prevention of atelectasis. , 1957, Journal of the American Medical Association.

[12]  B. Krieger,et al.  Calibration of respiratory inductive plethysmograph during natural breathing. , 1989, Journal of applied physiology.

[13]  C E Lundgren,et al.  Dead space in the breathing apparatus; interaction with ventilation. , 1995, Ergonomics.

[14]  E. Asmussen,et al.  Ventilatory response to CO2 during work at normal and at low oxygen tensions. , 1957, Acta physiologica Scandinavica.

[15]  O. G. Griffin,et al.  Tolerance and ventilatory response to inhaled CO2 during exercise and with inspiratory resistive loading. , 1979, The Annals of occupational hygiene.

[16]  G. R. Kelman,et al.  Effect of added dead-space on pulmonary ventilation during sub-maximal, steady-state exercise. , 1973, Quarterly Journal of Experimental Physiology and Cognate Medical Sciences.

[17]  D. J. Cunningham,et al.  Respiratory effects of breathing down a tube. , 1969, Respiration physiology.

[18]  P M Gustafsson,et al.  Evaluation of various models for respiratory inductance plethysmography calibration. , 1993, Journal of applied physiology.