ECG-gated pinhole SPECT in mice with millimeter spatial resolution

The authors have developed a single photon emission computed tomography (SPECT) technique for high resolution radiotracer imaging of mice where the object is rotated instead of the scintillation camera. The system uses a 21 cm focal length pinhole collimator with a 0.5 mm diameter aperture, resulting in magnification ranging from 7 to 10 and acquisition times from 60 to 90 minutes. This method employs a plastic mouse-holding tube designed to address specific problems associated with pinhole SPECT, including low count rates and correction for shift of the center of rotation. Images of a novel "mouse heart" phantom demonstrated good image quality, uniformity, and spatial resolution. A /sup 99m/Tc-sestamibi scan of a normal mouse, electrocardiogram-gated at over 400 beats per minute, allowed assessment of regional myocardial perfusion and evaluation of ventricular wall motion. An ungated perfusion scan produced images with millimeter spatial resolution and quality comparable to human images, allowing the visualization of the left and right ventricular myocardium.

[1]  S. Cherry,et al.  Performance evaluation of microPET: a high-resolution lutetium oxyorthosilicate PET scanner for animal imaging. , 1999, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[2]  William W. Moses,et al.  Conceptual design of a high-sensitivity small animal PET camera with 4/spl pi/ coverage , 1999 .

[3]  R Lecomte,et al.  High-resolution PET imaging for in vivo monitoring of tumor response after photodynamic therapy in mice. , 1999, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  Koichi Ogawa,et al.  Ultra high resolution pinhole SPECT for small animal study , 1998 .

[5]  A. Jeavons,et al.  A 3D HIDAC-PET camera with sub-millimetre resolution for imaging small animals , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[6]  A.J. Da Silva,et al.  An ultra high resolution ECG-gated myocardial imaging system for small animals , 1998, 1998 IEEE Nuclear Science Symposium Conference Record. 1998 IEEE Nuclear Science Symposium and Medical Imaging Conference (Cat. No.98CH36255).

[7]  P. Doevendans,et al.  Cardiovascular phenotyping in mice. , 1998, Cardiovascular research.

[8]  T E Hewett,et al.  Cardiac physiology in transgenic mice. , 1998, Circulation research.

[9]  K. Chien,et al.  Physiological assessment of complex cardiac phenotypes in genetically engineered mice. , 1997, The American journal of physiology.

[10]  S. Cherry,et al.  MicroPET: a high resolution PET scanner for imaging small animals , 1996, 1996 IEEE Nuclear Science Symposium. Conference Record.

[11]  Roger Lecomte,et al.  Initial results from the Sherbrooke avalanche photodiode positron tomograph , 1996 .

[12]  K. Chien,et al.  Genes and physiology: molecular physiology in genetically engineered animals. , 1996, The Journal of clinical investigation.

[13]  K. Paigen,et al.  A miracle enough: the power of mice , 1995, Nature Medicine.

[14]  R. Jaszczak,et al.  Pinhole collimation for ultra-high-resolution, small-field-of-view SPECT. , 1994, Physics in medicine and biology.

[15]  H. Atkins,et al.  Pinhole SPECT: an approach to in vivo high resolution SPECT imaging in small laboratory animals. , 1994, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[16]  K. Erlandsson,et al.  Small animal imaging with pinhole single‐photon emission computed tomography , 1994, Cancer.

[17]  R J Jaszczak,et al.  A filtered backprojection algorithm for pinhole SPECT with a displaced centre of rotation , 1994, Physics in medicine and biology.

[18]  A. Fischman,et al.  Cardiac blood-pool scintigraphy in rats and hamsters: comparison of five radiopharmaceuticals and three pinhole collimator apertures. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[19]  L. Feldkamp,et al.  Practical cone-beam algorithm , 1984 .