Noninvasive measurement of myocardial tissue volume change during systolic contraction and diastolic relaxation in the canine left ventricle

In coronary circulation the flow in epicardial arteries and veins is observed to be pulsatile and out of phase with each other. Theoretical considerations predict that this phenomenon extends to all levels of the vascular tree and leads to a cyclic fluctuation of regional tissue volume. Intramyocardial tissue volume change between end‐systole and end‐diastole was measured noninvasively with MRI in 10 closed‐chest beagles. The displacement encoding with stimulated‐echo technique was used to obtain pixel‐by‐pixel tissue displacement field between end‐diastole and end‐systole and vice versa in the midlevel left ventricle, from which the 3D strain matrix and volume changes were calculated. The volume change was between 0.8 ± 0.5% (mean ± STD) in the epicardial layer and 1.5 ± 0.6% in the subendocardial layer of the left ventricle. Tissue volume fluctuation reflects the amount of arterial inflow in a heartbeat under the assumption that regional arterial inflow and venous outflow have little time overlap. The corresponding perfusion level was estimated to be from (1.0 ± 0.6) ml/min/g in the epicardial layer to (1.7 ± 0.6) ml/min/g in the subendocardial layer, in good agreement with microsphere measurements in the same dog model. The result supports the notion of high arterial resistance at the microvascular level from intramyocardial pressure during systole. Magn Reson Med, 2006. Published 2006 Wiley‐Liss, Inc.

[1]  P. Anversa,et al.  Alterations of coronary blood flow and reserve with aging in Fischer 344 rats. , 1989, The American journal of physiology.

[2]  Daniel B Ennis,et al.  Visualization of tensor fields using superquadric glyphs , 2005, Magnetic resonance in medicine.

[3]  Frederick H Epstein,et al.  Displacement‐encoded cardiac MRI using cosine and sine modulation to eliminate (CANSEL) artifact‐generating echoes , 2004, Magnetic resonance in medicine.

[4]  Christopher M Kramer,et al.  Myocardial tissue tracking with two-dimensional cine displacement-encoded MR imaging: development and initial evaluation. , 2004, Radiology.

[5]  A Tedgui,et al.  Phasic regional myocardial inflow and outflow: comparison of theory and experiments. , 1990, The American journal of physiology.

[6]  H. Wen,et al.  High-resolution strain analysis of the human heart with fast-DENSE. , 1999, Journal of magnetic resonance.

[7]  R S Reneman,et al.  Porous medium finite element model of the beating left ventricle. , 1992, The American journal of physiology.

[8]  H. Wen,et al.  DENSE: displacement encoding with stimulated echoes in cardiac functional MRI. , 1999, Journal of magnetic resonance.

[9]  Eiji Toyota,et al.  Dynamic Changes in Three-Dimensional Architecture and Vascular Volume of Transmural Coronary Microvasculature Between Diastolic- and Systolic-Arrested Rat Hearts , 2002, Circulation.

[10]  B. Brundage,et al.  Reproducibility of left ventricular myocardial volume and mass measurements by ultrafast computed tomography. , 1991, Journal of the American College of Cardiology.

[11]  P. Callaghan,et al.  RAPID COMMUNICATION: NMR microscopy of dynamic displacements: k-space and q-space imaging , 1988 .

[12]  Donald L King,et al.  Noncompressibility of myocardium during systole with freehand three-dimensional echocardiography. , 2002, Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography.

[13]  H. Wen,et al.  Mixed echo train acquisition displacement encoding with stimulated echoes: An optimized DENSE method for in vivo functional imaging of the human heart , 2001, Magnetic resonance in medicine.

[14]  Han Wen,et al.  In vivo study of microcirculation in canine myocardium using the IVIM method † , 2003, Magnetic resonance in medicine.

[15]  S Sideman,et al.  An integrated model of LV muscle mechanics, coronary flow, and fluid and mass transport. , 1995, The American journal of physiology.

[16]  R A Robb,et al.  Mass of left ventricular myocardium estimated with dynamic spatial reconstructor. , 1984, The American journal of physiology.

[17]  D S Berman,et al.  Noninvasive quantification of left ventricular myocardial mass by gated proton nuclear magnetic resonance imaging. , 1987, Journal of the American College of Cardiology.

[18]  R Beyar,et al.  Determination of left ventricular mass by magnetic resonance imaging in hearts deformed by acute infarction. , 1989, Circulation.

[19]  F. Epstein,et al.  Complementary displacement‐encoded MRI for contrast‐enhanced infarct detection and quantification of myocardial function in mice , 2004, Magnetic resonance in medicine.

[20]  Jens Frahm,et al.  Stimulated echo imaging , 1985 .

[21]  E R McVeigh,et al.  Noninvasive measurement of three-dimensional myocardial deformation with tagged magnetic resonance imaging during graded local ischemia. , 1999, Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance.

[22]  Latest pulse sequence for displacement-encoded MR imaging incorporates essential technical improvements for multiphase measurement of intramyocardial strain. , 2004, Radiology.

[23]  Michael Jerosch-Herold,et al.  VENTRICULAR FUNCTION Evaluation of Myocardial Volume Heterogeneity During End-Diastole and End-Systole Using Cine MRI , 2004 .

[24]  I. Smith,et al.  Stimulated anti-echo selection in spatially localized NMR spectroscopy. , 1999, Journal of magnetic resonance.

[25]  V. Wedeen,et al.  Measuring Diffusion in the Presence of Material Strain , 1996, Journal of magnetic resonance. Series B.

[26]  E L Ritman,et al.  Dynamic intramyocardial blood volume: evaluation with a radiological opaque marker method. , 1992, The American journal of physiology.

[27]  Leon Axel,et al.  Global cardiac function using fast breath‐hold MRI: Validation of new acquisition and analysis techniques , 1997, Magnetic resonance in medicine.

[28]  M. L. Wood,et al.  Motion‐insensitive, steady‐state free precession imaging , 1990, Magnetic resonance in medicine.

[29]  J. Spaan Coronary Diastolic Pressure‐Flow Relation and Zero Flow Pressure Explained on the Basis of Intramyocardial Compliance , 1985, Circulation research.

[30]  R. Beyar,et al.  Dynamic interaction between myocardial contraction and coronary flow. , 1997, Advances in experimental medicine and biology.

[31]  E. Wu,et al.  Mapping cyclic change of regional myocardial blood volume using steady‐state susceptibility effect of iron oxide nanoparticles , 2004, Journal of magnetic resonance imaging : JMRI.

[32]  Andrew D McCulloch,et al.  Laminar fiber architecture and three-dimensional systolic mechanics in canine ventricular myocardium. , 1999, American journal of physiology. Heart and circulatory physiology.

[33]  J I Hoffman,et al.  Pressure-flow relations in coronary circulation. , 1990, Physiological reviews.